Loading…

Generation and validation of oxygenated volatile organic carbon standards for the 1995 Southern Oxidants Study Nashville Intensive

Two volatile organic compound (VOC) mixtures were made available and utilized for the calibration of instruments and intercomparison exercises at the Youth, Inc. (YI) site during the Southern Oxidants Study Nashville Intensive. Cylinder 1 contained 14 components (three nonmethane hydrocarbons (NMHCs...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Geophysical Research 1998-09, Vol.103 (D17), p.22
Main Authors: Apel, E C, Calvert, J G, Greenberg, J P, Riemer, D, Zika, R, Kleindienst, T E, Lonneman, W A, Fung, K, Fujita, E
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue D17
container_start_page 22
container_title Journal of Geophysical Research
container_volume 103
creator Apel, E C
Calvert, J G
Greenberg, J P
Riemer, D
Zika, R
Kleindienst, T E
Lonneman, W A
Fung, K
Fujita, E
description Two volatile organic compound (VOC) mixtures were made available and utilized for the calibration of instruments and intercomparison exercises at the Youth, Inc. (YI) site during the Southern Oxidants Study Nashville Intensive. Cylinder 1 contained 14 components (three nonmethane hydrocarbons (NMHCs) and 11 oxygen-containing VOCs (OVOCs)) and is referred to as OVOC1. Cylinder 2 contained four components (one NMHC and three OVOCs) and is referred to as OVOC2. The mixtures were prepared in high-pressure cylinders in the parts per million by volume (ppmv) range using calibrated syringe methods. Gas chromatographic (GC) and 2,4-dinitrophenylhydrazine (DNPH) cartridge/high-pressure liquid chromatographic (HPLC) systems were utilized in the calibration of the cylinders. GC detectors included the flame ionization detector (FID) and atomic emission detector (AED). Results obtained with the GC/FID systems for OVOCs were adjusted in terms of the effective carbon number (ECN), obtained from literature values, to correct for the reduced response of the FID for compounds containing oxygen, relative to compounds containing only carbon and hydrogen. Cylinder concentrations were derived and compared based on the ECN-adjusted FID results, the AED results, and the DNPH cartridge results. The various methods employed agreed to within approximately 15 percent. Both cylinders were stable (+/- 4 percent) over a period of 2 yr. (Author)
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_27542013</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>27542013</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_275420133</originalsourceid><addsrcrecordid>eNqNjDFvwkAMhW8oEgj4D57YkC4hIWWuSstCB7ojkzjkqsMu50sEa395T6I_oF7s5_e992QmNiuelzbPq7GZq37ZNEW5Lmw2MT9vxBQwOmFAbmBA75qHlBbkdj8TY6RkiE9vTyDhjOxqqDGcEqUxxTA0Cq0EiB1BttmUcJA-3YHh45b6OCocYt_cYY_aDc6nnh1HYnUDzcyoRa80_9tTs9i-fr68L7-DXHvSeLw4rcl7ZJJej3lVFrnNVqt_g78pJVTp</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>27542013</pqid></control><display><type>article</type><title>Generation and validation of oxygenated volatile organic carbon standards for the 1995 Southern Oxidants Study Nashville Intensive</title><source>Wiley-Blackwell AGU Digital Archive</source><creator>Apel, E C ; Calvert, J G ; Greenberg, J P ; Riemer, D ; Zika, R ; Kleindienst, T E ; Lonneman, W A ; Fung, K ; Fujita, E</creator><creatorcontrib>Apel, E C ; Calvert, J G ; Greenberg, J P ; Riemer, D ; Zika, R ; Kleindienst, T E ; Lonneman, W A ; Fung, K ; Fujita, E</creatorcontrib><description>Two volatile organic compound (VOC) mixtures were made available and utilized for the calibration of instruments and intercomparison exercises at the Youth, Inc. (YI) site during the Southern Oxidants Study Nashville Intensive. Cylinder 1 contained 14 components (three nonmethane hydrocarbons (NMHCs) and 11 oxygen-containing VOCs (OVOCs)) and is referred to as OVOC1. Cylinder 2 contained four components (one NMHC and three OVOCs) and is referred to as OVOC2. The mixtures were prepared in high-pressure cylinders in the parts per million by volume (ppmv) range using calibrated syringe methods. Gas chromatographic (GC) and 2,4-dinitrophenylhydrazine (DNPH) cartridge/high-pressure liquid chromatographic (HPLC) systems were utilized in the calibration of the cylinders. GC detectors included the flame ionization detector (FID) and atomic emission detector (AED). Results obtained with the GC/FID systems for OVOCs were adjusted in terms of the effective carbon number (ECN), obtained from literature values, to correct for the reduced response of the FID for compounds containing oxygen, relative to compounds containing only carbon and hydrogen. Cylinder concentrations were derived and compared based on the ECN-adjusted FID results, the AED results, and the DNPH cartridge results. The various methods employed agreed to within approximately 15 percent. Both cylinders were stable (+/- 4 percent) over a period of 2 yr. (Author)</description><identifier>ISSN: 0148-0227</identifier><language>eng</language><ispartof>Journal of Geophysical Research, 1998-09, Vol.103 (D17), p.22</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids></links><search><creatorcontrib>Apel, E C</creatorcontrib><creatorcontrib>Calvert, J G</creatorcontrib><creatorcontrib>Greenberg, J P</creatorcontrib><creatorcontrib>Riemer, D</creatorcontrib><creatorcontrib>Zika, R</creatorcontrib><creatorcontrib>Kleindienst, T E</creatorcontrib><creatorcontrib>Lonneman, W A</creatorcontrib><creatorcontrib>Fung, K</creatorcontrib><creatorcontrib>Fujita, E</creatorcontrib><title>Generation and validation of oxygenated volatile organic carbon standards for the 1995 Southern Oxidants Study Nashville Intensive</title><title>Journal of Geophysical Research</title><description>Two volatile organic compound (VOC) mixtures were made available and utilized for the calibration of instruments and intercomparison exercises at the Youth, Inc. (YI) site during the Southern Oxidants Study Nashville Intensive. Cylinder 1 contained 14 components (three nonmethane hydrocarbons (NMHCs) and 11 oxygen-containing VOCs (OVOCs)) and is referred to as OVOC1. Cylinder 2 contained four components (one NMHC and three OVOCs) and is referred to as OVOC2. The mixtures were prepared in high-pressure cylinders in the parts per million by volume (ppmv) range using calibrated syringe methods. Gas chromatographic (GC) and 2,4-dinitrophenylhydrazine (DNPH) cartridge/high-pressure liquid chromatographic (HPLC) systems were utilized in the calibration of the cylinders. GC detectors included the flame ionization detector (FID) and atomic emission detector (AED). Results obtained with the GC/FID systems for OVOCs were adjusted in terms of the effective carbon number (ECN), obtained from literature values, to correct for the reduced response of the FID for compounds containing oxygen, relative to compounds containing only carbon and hydrogen. Cylinder concentrations were derived and compared based on the ECN-adjusted FID results, the AED results, and the DNPH cartridge results. The various methods employed agreed to within approximately 15 percent. Both cylinders were stable (+/- 4 percent) over a period of 2 yr. (Author)</description><issn>0148-0227</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqNjDFvwkAMhW8oEgj4D57YkC4hIWWuSstCB7ojkzjkqsMu50sEa395T6I_oF7s5_e992QmNiuelzbPq7GZq37ZNEW5Lmw2MT9vxBQwOmFAbmBA75qHlBbkdj8TY6RkiE9vTyDhjOxqqDGcEqUxxTA0Cq0EiB1BttmUcJA-3YHh45b6OCocYt_cYY_aDc6nnh1HYnUDzcyoRa80_9tTs9i-fr68L7-DXHvSeLw4rcl7ZJJej3lVFrnNVqt_g78pJVTp</recordid><startdate>19980920</startdate><enddate>19980920</enddate><creator>Apel, E C</creator><creator>Calvert, J G</creator><creator>Greenberg, J P</creator><creator>Riemer, D</creator><creator>Zika, R</creator><creator>Kleindienst, T E</creator><creator>Lonneman, W A</creator><creator>Fung, K</creator><creator>Fujita, E</creator><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>19980920</creationdate><title>Generation and validation of oxygenated volatile organic carbon standards for the 1995 Southern Oxidants Study Nashville Intensive</title><author>Apel, E C ; Calvert, J G ; Greenberg, J P ; Riemer, D ; Zika, R ; Kleindienst, T E ; Lonneman, W A ; Fung, K ; Fujita, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_275420133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Apel, E C</creatorcontrib><creatorcontrib>Calvert, J G</creatorcontrib><creatorcontrib>Greenberg, J P</creatorcontrib><creatorcontrib>Riemer, D</creatorcontrib><creatorcontrib>Zika, R</creatorcontrib><creatorcontrib>Kleindienst, T E</creatorcontrib><creatorcontrib>Lonneman, W A</creatorcontrib><creatorcontrib>Fung, K</creatorcontrib><creatorcontrib>Fujita, E</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of Geophysical Research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Apel, E C</au><au>Calvert, J G</au><au>Greenberg, J P</au><au>Riemer, D</au><au>Zika, R</au><au>Kleindienst, T E</au><au>Lonneman, W A</au><au>Fung, K</au><au>Fujita, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Generation and validation of oxygenated volatile organic carbon standards for the 1995 Southern Oxidants Study Nashville Intensive</atitle><jtitle>Journal of Geophysical Research</jtitle><date>1998-09-20</date><risdate>1998</risdate><volume>103</volume><issue>D17</issue><spage>22</spage><pages>22-</pages><issn>0148-0227</issn><abstract>Two volatile organic compound (VOC) mixtures were made available and utilized for the calibration of instruments and intercomparison exercises at the Youth, Inc. (YI) site during the Southern Oxidants Study Nashville Intensive. Cylinder 1 contained 14 components (three nonmethane hydrocarbons (NMHCs) and 11 oxygen-containing VOCs (OVOCs)) and is referred to as OVOC1. Cylinder 2 contained four components (one NMHC and three OVOCs) and is referred to as OVOC2. The mixtures were prepared in high-pressure cylinders in the parts per million by volume (ppmv) range using calibrated syringe methods. Gas chromatographic (GC) and 2,4-dinitrophenylhydrazine (DNPH) cartridge/high-pressure liquid chromatographic (HPLC) systems were utilized in the calibration of the cylinders. GC detectors included the flame ionization detector (FID) and atomic emission detector (AED). Results obtained with the GC/FID systems for OVOCs were adjusted in terms of the effective carbon number (ECN), obtained from literature values, to correct for the reduced response of the FID for compounds containing oxygen, relative to compounds containing only carbon and hydrogen. Cylinder concentrations were derived and compared based on the ECN-adjusted FID results, the AED results, and the DNPH cartridge results. The various methods employed agreed to within approximately 15 percent. Both cylinders were stable (+/- 4 percent) over a period of 2 yr. (Author)</abstract></addata></record>
fulltext fulltext
identifier ISSN: 0148-0227
ispartof Journal of Geophysical Research, 1998-09, Vol.103 (D17), p.22
issn 0148-0227
language eng
recordid cdi_proquest_miscellaneous_27542013
source Wiley-Blackwell AGU Digital Archive
title Generation and validation of oxygenated volatile organic carbon standards for the 1995 Southern Oxidants Study Nashville Intensive
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T08%3A07%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Generation%20and%20validation%20of%20oxygenated%20volatile%20organic%20carbon%20standards%20for%20the%201995%20Southern%20Oxidants%20Study%20Nashville%20Intensive&rft.jtitle=Journal%20of%20Geophysical%20Research&rft.au=Apel,%20E%20C&rft.date=1998-09-20&rft.volume=103&rft.issue=D17&rft.spage=22&rft.pages=22-&rft.issn=0148-0227&rft_id=info:doi/&rft_dat=%3Cproquest%3E27542013%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_miscellaneous_275420133%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=27542013&rft_id=info:pmid/&rfr_iscdi=true