Loading…
Near-infrared transmittance spectroscopy: a potential tool for non-destructive determination of oil content in groundnuts
The oil content of 64 samples of groundnut kernels, representing 47 genotypes, was determined by the conventional Soxhlet extraction procedure (OilSOX). The values of OilSOX ranged from 403 to 536 g kg−1. The optical densities (ODs) of these samples were determined at 12 wavelengths (918, 928, 940,...
Saved in:
Published in: | Journal of the science of food and agriculture 2000-01, Vol.80 (2), p.237-240 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The oil content of 64 samples of groundnut kernels, representing 47 genotypes, was determined by the conventional Soxhlet extraction procedure (OilSOX). The values of OilSOX ranged from 403 to 536 g kg−1. The optical densities (ODs) of these samples were determined at 12 wavelengths (918, 928, 940, 950, 968, 975, 985, 998, 1010, 1023, 1037 and 1045 nm) in the near‐infrared (NIR) region using a food composition analyser (essentially a filter‐based NIR spectrophotometer). The instrument also recorded the temperatures of the sample (TempS) and the air (TempA) surrounding it. A sample holder (75 mm × 150 mm; optical path length 25 mm) was used for optical density measurement. The data obtained were subjected to multiple linear regression analysis using the ODs at 12 wavelengths, TempS and TempA as the independent (predictor) variables, and OilSOX as the dependent variable. The multiple linear regression equation comprising 14 predictors showed a significant relationship between predicted values of oil content (OilNIR) and OilSOX. The standard error of calibration and the coefficient of determination for calibration (R 2c) were 3.54 and 0.821 respectively, while the standard error of prediction and the coefficient of determination for prediction were 5.82 and 0.865 respectively. The ratio of standard error of calibration and standard error of prediction was 0.608. The differences between OilSOX and OilNIR were less than ± 20 g kg−1 for samples having oil contents in the range from 480 to 510 g kg−1. However, for samples having OilSOX lower than 480 g kg−1 or higher than 510 g kg−1, differences greater than ± 20 g kg−1 were observed. There exists scope for further refining the regression equation by using a larger number of samples for generating optical data. The results demonstrated the potential of NIR transmittance spectroscopy for determining the oil content of groundnuts in a non‐destructive manner.
© 2000 Society of Chemical Industry |
---|---|
ISSN: | 0022-5142 1097-0010 |
DOI: | 10.1002/(SICI)1097-0010(20000115)80:2<237::AID-JSFA523>3.0.CO;2-9 |