Loading…

Determination of trace perchlorate in river water by ion chromatography with online matrix removal and sample concentration

This paper proposes a simple ion chromatographic approach to determine trace amounts of perchlorate in river water samples. Determination of the trace perchlorate by ion chromatography typically faces two challenges: interference by matrix ions such as chloride, nitrate, and sulfate in the samples a...

Full description

Saved in:
Bibliographic Details
Published in:Analytical sciences 2023-05, Vol.39 (5), p.689-694
Main Authors: Nishimura, Madoka, Nakaya, Yukari, Kashimoto, Mao, Imai, Shoji, Tanaka, Hideji, Takeuchi, Masaki
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c342t-55fb3b89f149ed2d4394126d0c5c0a4e0810b8929e463a38cc28e94cf074c6153
container_end_page 694
container_issue 5
container_start_page 689
container_title Analytical sciences
container_volume 39
creator Nishimura, Madoka
Nakaya, Yukari
Kashimoto, Mao
Imai, Shoji
Tanaka, Hideji
Takeuchi, Masaki
description This paper proposes a simple ion chromatographic approach to determine trace amounts of perchlorate in river water samples. Determination of the trace perchlorate by ion chromatography typically faces two challenges: interference by matrix ions such as chloride, nitrate, and sulfate in the samples and insufficient detection sensitivity. In the present study, online pretreatment of the samples with an OnGuard II Ba/Ag/H disposable sample pretreatment cartridge prevented the sulfate peak tailing from overlapping with the perchlorate peak on the chromatogram. In addition, the matrix removal enabled as large as 10 mL of sample to be loaded into a high exchange capacity anion concentrator, significantly improving perchlorate's detection sensitivity. The proposed approach achieved a detection limit ( S / N  = 3) of 0.046 µg L −1 without using a costly mass spectrometer and successfully determined sub µg L −1 levels of perchlorate in river water. Graphical abstract
doi_str_mv 10.1007/s44211-022-00262-9
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2765776489</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2765776489</sourcerecordid><originalsourceid>FETCH-LOGICAL-c342t-55fb3b89f149ed2d4394126d0c5c0a4e0810b8929e463a38cc28e94cf074c6153</originalsourceid><addsrcrecordid>eNp9kE1P3DAQhq0KVLbAH-gB-cglrT12nOSIoF8SUi_lbHmdCWuU2GGcha765-vtAseeRp555h35YeyjFJ-kEM3nrDVIWQmASggwUHXv2Eoq3VYA2hyxleikqIzS4oR9yPlBCAktwHt2ooxRta7Viv25wQVpCtEtIUWeBr6Q88hnJL8ZE7kFeYicwhMSfy4v4usd36N-Q2lyS7onN292_DksG57iGCLy0qbwmxNO6cmN3MWeZzfNI3KfosdYTuyvnbHjwY0Zz1_qKbv7-uXX9ffq9ue3H9dXt5VXGpaqroe1WrfdIHWHPfRadVqC6YWvvXAaRStFGUOH2iinWu-hxU77QTTaG1mrU3Z5yJ0pPW4xL3YK2eM4uohpmy00pm4ao9uuoHBAPaWcCQc7U5gc7awUdi_dHqTbIt3-k273Sxcv-dv1hP3byqvlAqgDkMso3iPZh7SlWP78v9i_qbiO-A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2765776489</pqid></control><display><type>article</type><title>Determination of trace perchlorate in river water by ion chromatography with online matrix removal and sample concentration</title><source>Springer Nature</source><creator>Nishimura, Madoka ; Nakaya, Yukari ; Kashimoto, Mao ; Imai, Shoji ; Tanaka, Hideji ; Takeuchi, Masaki</creator><creatorcontrib>Nishimura, Madoka ; Nakaya, Yukari ; Kashimoto, Mao ; Imai, Shoji ; Tanaka, Hideji ; Takeuchi, Masaki</creatorcontrib><description>This paper proposes a simple ion chromatographic approach to determine trace amounts of perchlorate in river water samples. Determination of the trace perchlorate by ion chromatography typically faces two challenges: interference by matrix ions such as chloride, nitrate, and sulfate in the samples and insufficient detection sensitivity. In the present study, online pretreatment of the samples with an OnGuard II Ba/Ag/H disposable sample pretreatment cartridge prevented the sulfate peak tailing from overlapping with the perchlorate peak on the chromatogram. In addition, the matrix removal enabled as large as 10 mL of sample to be loaded into a high exchange capacity anion concentrator, significantly improving perchlorate's detection sensitivity. The proposed approach achieved a detection limit ( S / N  = 3) of 0.046 µg L −1 without using a costly mass spectrometer and successfully determined sub µg L −1 levels of perchlorate in river water. Graphical abstract</description><identifier>ISSN: 0910-6340</identifier><identifier>EISSN: 1348-2246</identifier><identifier>DOI: 10.1007/s44211-022-00262-9</identifier><identifier>PMID: 36635453</identifier><language>eng</language><publisher>Singapore: Springer Nature Singapore</publisher><subject>Analytical Chemistry ; Chemistry ; Chemistry and Materials Science ; Special Issue: Original Paper</subject><ispartof>Analytical sciences, 2023-05, Vol.39 (5), p.689-694</ispartof><rights>The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><rights>2023. The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c342t-55fb3b89f149ed2d4394126d0c5c0a4e0810b8929e463a38cc28e94cf074c6153</cites><orcidid>0000-0001-6193-0074</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36635453$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nishimura, Madoka</creatorcontrib><creatorcontrib>Nakaya, Yukari</creatorcontrib><creatorcontrib>Kashimoto, Mao</creatorcontrib><creatorcontrib>Imai, Shoji</creatorcontrib><creatorcontrib>Tanaka, Hideji</creatorcontrib><creatorcontrib>Takeuchi, Masaki</creatorcontrib><title>Determination of trace perchlorate in river water by ion chromatography with online matrix removal and sample concentration</title><title>Analytical sciences</title><addtitle>ANAL. SCI</addtitle><addtitle>Anal Sci</addtitle><description>This paper proposes a simple ion chromatographic approach to determine trace amounts of perchlorate in river water samples. Determination of the trace perchlorate by ion chromatography typically faces two challenges: interference by matrix ions such as chloride, nitrate, and sulfate in the samples and insufficient detection sensitivity. In the present study, online pretreatment of the samples with an OnGuard II Ba/Ag/H disposable sample pretreatment cartridge prevented the sulfate peak tailing from overlapping with the perchlorate peak on the chromatogram. In addition, the matrix removal enabled as large as 10 mL of sample to be loaded into a high exchange capacity anion concentrator, significantly improving perchlorate's detection sensitivity. The proposed approach achieved a detection limit ( S / N  = 3) of 0.046 µg L −1 without using a costly mass spectrometer and successfully determined sub µg L −1 levels of perchlorate in river water. Graphical abstract</description><subject>Analytical Chemistry</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Special Issue: Original Paper</subject><issn>0910-6340</issn><issn>1348-2246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kE1P3DAQhq0KVLbAH-gB-cglrT12nOSIoF8SUi_lbHmdCWuU2GGcha765-vtAseeRp555h35YeyjFJ-kEM3nrDVIWQmASggwUHXv2Eoq3VYA2hyxleikqIzS4oR9yPlBCAktwHt2ooxRta7Viv25wQVpCtEtIUWeBr6Q88hnJL8ZE7kFeYicwhMSfy4v4usd36N-Q2lyS7onN292_DksG57iGCLy0qbwmxNO6cmN3MWeZzfNI3KfosdYTuyvnbHjwY0Zz1_qKbv7-uXX9ffq9ue3H9dXt5VXGpaqroe1WrfdIHWHPfRadVqC6YWvvXAaRStFGUOH2iinWu-hxU77QTTaG1mrU3Z5yJ0pPW4xL3YK2eM4uohpmy00pm4ao9uuoHBAPaWcCQc7U5gc7awUdi_dHqTbIt3-k273Sxcv-dv1hP3byqvlAqgDkMso3iPZh7SlWP78v9i_qbiO-A</recordid><startdate>20230501</startdate><enddate>20230501</enddate><creator>Nishimura, Madoka</creator><creator>Nakaya, Yukari</creator><creator>Kashimoto, Mao</creator><creator>Imai, Shoji</creator><creator>Tanaka, Hideji</creator><creator>Takeuchi, Masaki</creator><general>Springer Nature Singapore</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-6193-0074</orcidid></search><sort><creationdate>20230501</creationdate><title>Determination of trace perchlorate in river water by ion chromatography with online matrix removal and sample concentration</title><author>Nishimura, Madoka ; Nakaya, Yukari ; Kashimoto, Mao ; Imai, Shoji ; Tanaka, Hideji ; Takeuchi, Masaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c342t-55fb3b89f149ed2d4394126d0c5c0a4e0810b8929e463a38cc28e94cf074c6153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Analytical Chemistry</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Special Issue: Original Paper</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nishimura, Madoka</creatorcontrib><creatorcontrib>Nakaya, Yukari</creatorcontrib><creatorcontrib>Kashimoto, Mao</creatorcontrib><creatorcontrib>Imai, Shoji</creatorcontrib><creatorcontrib>Tanaka, Hideji</creatorcontrib><creatorcontrib>Takeuchi, Masaki</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nishimura, Madoka</au><au>Nakaya, Yukari</au><au>Kashimoto, Mao</au><au>Imai, Shoji</au><au>Tanaka, Hideji</au><au>Takeuchi, Masaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of trace perchlorate in river water by ion chromatography with online matrix removal and sample concentration</atitle><jtitle>Analytical sciences</jtitle><stitle>ANAL. SCI</stitle><addtitle>Anal Sci</addtitle><date>2023-05-01</date><risdate>2023</risdate><volume>39</volume><issue>5</issue><spage>689</spage><epage>694</epage><pages>689-694</pages><issn>0910-6340</issn><eissn>1348-2246</eissn><abstract>This paper proposes a simple ion chromatographic approach to determine trace amounts of perchlorate in river water samples. Determination of the trace perchlorate by ion chromatography typically faces two challenges: interference by matrix ions such as chloride, nitrate, and sulfate in the samples and insufficient detection sensitivity. In the present study, online pretreatment of the samples with an OnGuard II Ba/Ag/H disposable sample pretreatment cartridge prevented the sulfate peak tailing from overlapping with the perchlorate peak on the chromatogram. In addition, the matrix removal enabled as large as 10 mL of sample to be loaded into a high exchange capacity anion concentrator, significantly improving perchlorate's detection sensitivity. The proposed approach achieved a detection limit ( S / N  = 3) of 0.046 µg L −1 without using a costly mass spectrometer and successfully determined sub µg L −1 levels of perchlorate in river water. Graphical abstract</abstract><cop>Singapore</cop><pub>Springer Nature Singapore</pub><pmid>36635453</pmid><doi>10.1007/s44211-022-00262-9</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0001-6193-0074</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0910-6340
ispartof Analytical sciences, 2023-05, Vol.39 (5), p.689-694
issn 0910-6340
1348-2246
language eng
recordid cdi_proquest_miscellaneous_2765776489
source Springer Nature
subjects Analytical Chemistry
Chemistry
Chemistry and Materials Science
Special Issue: Original Paper
title Determination of trace perchlorate in river water by ion chromatography with online matrix removal and sample concentration
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T23%3A40%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20trace%20perchlorate%20in%20river%20water%20by%20ion%20chromatography%20with%20online%20matrix%20removal%20and%20sample%20concentration&rft.jtitle=Analytical%20sciences&rft.au=Nishimura,%20Madoka&rft.date=2023-05-01&rft.volume=39&rft.issue=5&rft.spage=689&rft.epage=694&rft.pages=689-694&rft.issn=0910-6340&rft.eissn=1348-2246&rft_id=info:doi/10.1007/s44211-022-00262-9&rft_dat=%3Cproquest_cross%3E2765776489%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c342t-55fb3b89f149ed2d4394126d0c5c0a4e0810b8929e463a38cc28e94cf074c6153%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2765776489&rft_id=info:pmid/36635453&rfr_iscdi=true