Loading…

Application of serum pools in insulin harmonization: Commutability and stability

Background Recalibration using serum pools assigned by higher-order reference methods had been demonstrated to be effective in improving the agreement among insulin immunoassays. To promote the application of serum pools in insulin harmonization, this study analyzed serum pools’ commutability betwee...

Full description

Saved in:
Bibliographic Details
Published in:Annals of clinical biochemistry 2023-05, Vol.60 (3), p.199-207
Main Authors: Deng, Yuhang, Zhang, Chao, Wang, Jing, Zeng, Jie, Zhang, Jiangtao, Zhang, Tianjiao, Zhao, Haijian, Li, Miao, Zhao, Yang, Gan, Wei, Shao, Yan, Yu, Hongyuan, Zhou, Weiyan, Zhang, Chuanbao
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c292t-d2db560182c960ebe201e62b5579ff396e18736d401a2d08dbe636eb8ff381123
container_end_page 207
container_issue 3
container_start_page 199
container_title Annals of clinical biochemistry
container_volume 60
creator Deng, Yuhang
Zhang, Chao
Wang, Jing
Zeng, Jie
Zhang, Jiangtao
Zhang, Tianjiao
Zhao, Haijian
Li, Miao
Zhao, Yang
Gan, Wei
Shao, Yan
Yu, Hongyuan
Zhou, Weiyan
Zhang, Chuanbao
description Background Recalibration using serum pools assigned by higher-order reference methods had been demonstrated to be effective in improving the agreement among insulin immunoassays. To promote the application of serum pools in insulin harmonization, this study analyzed serum pools’ commutability between insulin immunoassays, and their short- and long-term stability at different temperatures. The agreement between commonly used immunoassays was also evaluated. Methods Insulin in 69 individual serum samples, 10 serum pools, and three EQA samples (lyophilized powder of serum pools) were detected by six widely used immunoassays. The commutability of serum pools and EQA samples was evaluated according to the IFCC-recommended approach. Serum pools’ stability at different temperatures was investigated by placing them at various temperatures for varying lengths of time. Individual serum samples’ results were analyzed using the Bland–Altman and Passing and Bablok regression analyses. Results Serum pools were commutable among most assays, the EQA samples—lyophilized serum pools—were non-commutable among most assays. Serum pools can be stably stored at −20°C and −80°C for at least one year, but can only be stably stored at room temperature for twenty-four hours. Significant relative differences were observed among assays. Recalibration using serum pools can only improve the assays’ agreement at middle and high insulin levels, but not at low levels. Conclusions Serum pools were commutable and stable for insulin measurement and can be used in insulin harmonization. The existing EQA materials were non-commutable between most assays, and other EQA materials, such as serum pools, should be studied.
doi_str_mv 10.1177/00045632231159291
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2774496781</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_00045632231159291</sage_id><sourcerecordid>2774496781</sourcerecordid><originalsourceid>FETCH-LOGICAL-c292t-d2db560182c960ebe201e62b5579ff396e18736d401a2d08dbe636eb8ff381123</originalsourceid><addsrcrecordid>eNp9kE9LxDAQxYMo7rr6AbxIj166ziRt0npbFv_Bgh70XNI21SxtU5PmsH56s-6uF0EYGB7zew_mEXKJMEcU4gYAkpQzShlimtMcj8gURZrFCIDHZLq9x1tgQs6cWwdJBcApmTAuUkgYTMnLYhhaXclRmz4yTeSU9V00GNO6SPdhnG_D_pC2M73--uFuo6XpOj_KUrd63ESyryN3UOfkpJGtUxf7PSNv93evy8d49fzwtFys4ormdIxrWpcpB8xolXNQpaKAitMyTUXeNCznCjPBeJ0ASlpDVpeKM67KLBwzRMpm5HqXO1jz6ZUbi067SrWt7JXxrqBCJEnORYYBxR1aWeOcVU0xWN1JuykQim2RxZ8ig-dqH-_LTtW_jkNzAZjvACffVbE23vbh3X8SvwGTQXq5</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2774496781</pqid></control><display><type>article</type><title>Application of serum pools in insulin harmonization: Commutability and stability</title><source>Sage Journals Online</source><creator>Deng, Yuhang ; Zhang, Chao ; Wang, Jing ; Zeng, Jie ; Zhang, Jiangtao ; Zhang, Tianjiao ; Zhao, Haijian ; Li, Miao ; Zhao, Yang ; Gan, Wei ; Shao, Yan ; Yu, Hongyuan ; Zhou, Weiyan ; Zhang, Chuanbao</creator><creatorcontrib>Deng, Yuhang ; Zhang, Chao ; Wang, Jing ; Zeng, Jie ; Zhang, Jiangtao ; Zhang, Tianjiao ; Zhao, Haijian ; Li, Miao ; Zhao, Yang ; Gan, Wei ; Shao, Yan ; Yu, Hongyuan ; Zhou, Weiyan ; Zhang, Chuanbao</creatorcontrib><description>Background Recalibration using serum pools assigned by higher-order reference methods had been demonstrated to be effective in improving the agreement among insulin immunoassays. To promote the application of serum pools in insulin harmonization, this study analyzed serum pools’ commutability between insulin immunoassays, and their short- and long-term stability at different temperatures. The agreement between commonly used immunoassays was also evaluated. Methods Insulin in 69 individual serum samples, 10 serum pools, and three EQA samples (lyophilized powder of serum pools) were detected by six widely used immunoassays. The commutability of serum pools and EQA samples was evaluated according to the IFCC-recommended approach. Serum pools’ stability at different temperatures was investigated by placing them at various temperatures for varying lengths of time. Individual serum samples’ results were analyzed using the Bland–Altman and Passing and Bablok regression analyses. Results Serum pools were commutable among most assays, the EQA samples—lyophilized serum pools—were non-commutable among most assays. Serum pools can be stably stored at −20°C and −80°C for at least one year, but can only be stably stored at room temperature for twenty-four hours. Significant relative differences were observed among assays. Recalibration using serum pools can only improve the assays’ agreement at middle and high insulin levels, but not at low levels. Conclusions Serum pools were commutable and stable for insulin measurement and can be used in insulin harmonization. The existing EQA materials were non-commutable between most assays, and other EQA materials, such as serum pools, should be studied.</description><identifier>ISSN: 0004-5632</identifier><identifier>EISSN: 1758-1001</identifier><identifier>DOI: 10.1177/00045632231159291</identifier><identifier>PMID: 36750430</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Biological Assay ; Humans ; Immunoassay ; Insulin ; Reference Standards</subject><ispartof>Annals of clinical biochemistry, 2023-05, Vol.60 (3), p.199-207</ispartof><rights>The Author(s) 2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c292t-d2db560182c960ebe201e62b5579ff396e18736d401a2d08dbe636eb8ff381123</cites><orcidid>0000-0003-4910-0267</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925,79364</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36750430$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Deng, Yuhang</creatorcontrib><creatorcontrib>Zhang, Chao</creatorcontrib><creatorcontrib>Wang, Jing</creatorcontrib><creatorcontrib>Zeng, Jie</creatorcontrib><creatorcontrib>Zhang, Jiangtao</creatorcontrib><creatorcontrib>Zhang, Tianjiao</creatorcontrib><creatorcontrib>Zhao, Haijian</creatorcontrib><creatorcontrib>Li, Miao</creatorcontrib><creatorcontrib>Zhao, Yang</creatorcontrib><creatorcontrib>Gan, Wei</creatorcontrib><creatorcontrib>Shao, Yan</creatorcontrib><creatorcontrib>Yu, Hongyuan</creatorcontrib><creatorcontrib>Zhou, Weiyan</creatorcontrib><creatorcontrib>Zhang, Chuanbao</creatorcontrib><title>Application of serum pools in insulin harmonization: Commutability and stability</title><title>Annals of clinical biochemistry</title><addtitle>Ann Clin Biochem</addtitle><description>Background Recalibration using serum pools assigned by higher-order reference methods had been demonstrated to be effective in improving the agreement among insulin immunoassays. To promote the application of serum pools in insulin harmonization, this study analyzed serum pools’ commutability between insulin immunoassays, and their short- and long-term stability at different temperatures. The agreement between commonly used immunoassays was also evaluated. Methods Insulin in 69 individual serum samples, 10 serum pools, and three EQA samples (lyophilized powder of serum pools) were detected by six widely used immunoassays. The commutability of serum pools and EQA samples was evaluated according to the IFCC-recommended approach. Serum pools’ stability at different temperatures was investigated by placing them at various temperatures for varying lengths of time. Individual serum samples’ results were analyzed using the Bland–Altman and Passing and Bablok regression analyses. Results Serum pools were commutable among most assays, the EQA samples—lyophilized serum pools—were non-commutable among most assays. Serum pools can be stably stored at −20°C and −80°C for at least one year, but can only be stably stored at room temperature for twenty-four hours. Significant relative differences were observed among assays. Recalibration using serum pools can only improve the assays’ agreement at middle and high insulin levels, but not at low levels. Conclusions Serum pools were commutable and stable for insulin measurement and can be used in insulin harmonization. The existing EQA materials were non-commutable between most assays, and other EQA materials, such as serum pools, should be studied.</description><subject>Biological Assay</subject><subject>Humans</subject><subject>Immunoassay</subject><subject>Insulin</subject><subject>Reference Standards</subject><issn>0004-5632</issn><issn>1758-1001</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kE9LxDAQxYMo7rr6AbxIj166ziRt0npbFv_Bgh70XNI21SxtU5PmsH56s-6uF0EYGB7zew_mEXKJMEcU4gYAkpQzShlimtMcj8gURZrFCIDHZLq9x1tgQs6cWwdJBcApmTAuUkgYTMnLYhhaXclRmz4yTeSU9V00GNO6SPdhnG_D_pC2M73--uFuo6XpOj_KUrd63ESyryN3UOfkpJGtUxf7PSNv93evy8d49fzwtFys4ormdIxrWpcpB8xolXNQpaKAitMyTUXeNCznCjPBeJ0ASlpDVpeKM67KLBwzRMpm5HqXO1jz6ZUbi067SrWt7JXxrqBCJEnORYYBxR1aWeOcVU0xWN1JuykQim2RxZ8ig-dqH-_LTtW_jkNzAZjvACffVbE23vbh3X8SvwGTQXq5</recordid><startdate>202305</startdate><enddate>202305</enddate><creator>Deng, Yuhang</creator><creator>Zhang, Chao</creator><creator>Wang, Jing</creator><creator>Zeng, Jie</creator><creator>Zhang, Jiangtao</creator><creator>Zhang, Tianjiao</creator><creator>Zhao, Haijian</creator><creator>Li, Miao</creator><creator>Zhao, Yang</creator><creator>Gan, Wei</creator><creator>Shao, Yan</creator><creator>Yu, Hongyuan</creator><creator>Zhou, Weiyan</creator><creator>Zhang, Chuanbao</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4910-0267</orcidid></search><sort><creationdate>202305</creationdate><title>Application of serum pools in insulin harmonization: Commutability and stability</title><author>Deng, Yuhang ; Zhang, Chao ; Wang, Jing ; Zeng, Jie ; Zhang, Jiangtao ; Zhang, Tianjiao ; Zhao, Haijian ; Li, Miao ; Zhao, Yang ; Gan, Wei ; Shao, Yan ; Yu, Hongyuan ; Zhou, Weiyan ; Zhang, Chuanbao</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c292t-d2db560182c960ebe201e62b5579ff396e18736d401a2d08dbe636eb8ff381123</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Biological Assay</topic><topic>Humans</topic><topic>Immunoassay</topic><topic>Insulin</topic><topic>Reference Standards</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Deng, Yuhang</creatorcontrib><creatorcontrib>Zhang, Chao</creatorcontrib><creatorcontrib>Wang, Jing</creatorcontrib><creatorcontrib>Zeng, Jie</creatorcontrib><creatorcontrib>Zhang, Jiangtao</creatorcontrib><creatorcontrib>Zhang, Tianjiao</creatorcontrib><creatorcontrib>Zhao, Haijian</creatorcontrib><creatorcontrib>Li, Miao</creatorcontrib><creatorcontrib>Zhao, Yang</creatorcontrib><creatorcontrib>Gan, Wei</creatorcontrib><creatorcontrib>Shao, Yan</creatorcontrib><creatorcontrib>Yu, Hongyuan</creatorcontrib><creatorcontrib>Zhou, Weiyan</creatorcontrib><creatorcontrib>Zhang, Chuanbao</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Annals of clinical biochemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Deng, Yuhang</au><au>Zhang, Chao</au><au>Wang, Jing</au><au>Zeng, Jie</au><au>Zhang, Jiangtao</au><au>Zhang, Tianjiao</au><au>Zhao, Haijian</au><au>Li, Miao</au><au>Zhao, Yang</au><au>Gan, Wei</au><au>Shao, Yan</au><au>Yu, Hongyuan</au><au>Zhou, Weiyan</au><au>Zhang, Chuanbao</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of serum pools in insulin harmonization: Commutability and stability</atitle><jtitle>Annals of clinical biochemistry</jtitle><addtitle>Ann Clin Biochem</addtitle><date>2023-05</date><risdate>2023</risdate><volume>60</volume><issue>3</issue><spage>199</spage><epage>207</epage><pages>199-207</pages><issn>0004-5632</issn><eissn>1758-1001</eissn><abstract>Background Recalibration using serum pools assigned by higher-order reference methods had been demonstrated to be effective in improving the agreement among insulin immunoassays. To promote the application of serum pools in insulin harmonization, this study analyzed serum pools’ commutability between insulin immunoassays, and their short- and long-term stability at different temperatures. The agreement between commonly used immunoassays was also evaluated. Methods Insulin in 69 individual serum samples, 10 serum pools, and three EQA samples (lyophilized powder of serum pools) were detected by six widely used immunoassays. The commutability of serum pools and EQA samples was evaluated according to the IFCC-recommended approach. Serum pools’ stability at different temperatures was investigated by placing them at various temperatures for varying lengths of time. Individual serum samples’ results were analyzed using the Bland–Altman and Passing and Bablok regression analyses. Results Serum pools were commutable among most assays, the EQA samples—lyophilized serum pools—were non-commutable among most assays. Serum pools can be stably stored at −20°C and −80°C for at least one year, but can only be stably stored at room temperature for twenty-four hours. Significant relative differences were observed among assays. Recalibration using serum pools can only improve the assays’ agreement at middle and high insulin levels, but not at low levels. Conclusions Serum pools were commutable and stable for insulin measurement and can be used in insulin harmonization. The existing EQA materials were non-commutable between most assays, and other EQA materials, such as serum pools, should be studied.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>36750430</pmid><doi>10.1177/00045632231159291</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0003-4910-0267</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0004-5632
ispartof Annals of clinical biochemistry, 2023-05, Vol.60 (3), p.199-207
issn 0004-5632
1758-1001
language eng
recordid cdi_proquest_miscellaneous_2774496781
source Sage Journals Online
subjects Biological Assay
Humans
Immunoassay
Insulin
Reference Standards
title Application of serum pools in insulin harmonization: Commutability and stability
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T22%3A06%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%20serum%20pools%20in%20insulin%20harmonization:%20Commutability%20and%20stability&rft.jtitle=Annals%20of%20clinical%20biochemistry&rft.au=Deng,%20Yuhang&rft.date=2023-05&rft.volume=60&rft.issue=3&rft.spage=199&rft.epage=207&rft.pages=199-207&rft.issn=0004-5632&rft.eissn=1758-1001&rft_id=info:doi/10.1177/00045632231159291&rft_dat=%3Cproquest_cross%3E2774496781%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c292t-d2db560182c960ebe201e62b5579ff396e18736d401a2d08dbe636eb8ff381123%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2774496781&rft_id=info:pmid/36750430&rft_sage_id=10.1177_00045632231159291&rfr_iscdi=true