Loading…

The effect of change in flow rate on the vibration of double-suction centrifugal pumps

Abstract This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that wil...

Full description

Saved in:
Bibliographic Details
Published in:Proceedings of the Institution of Mechanical Engineers. Part E, Journal of process mechanical engineering Journal of process mechanical engineering, 2002-01, Vol.216 (1), p.47-58
Main Authors: Hodkiewicz, M R, Norton, M P
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract This investigation identifies changes in the character of vibration measured on a pump bearing housing resulting from flow below the best efficiency point for industrial double-suction single-stage units with different wear conditions. The paper develops a set of vibration features that will assist in identifying low flow conditions in double-suction pumps.
ISSN:0954-4089
2041-3009
DOI:10.1243/095440802760075030