Modeling of debris cooling with annular gap in the lower RPV and verification based on ALPHA experiments
For severe accident assessment in a light water reactor, heat transfer models in a narrow annular gap between the overheated core debris and the reactor pressure vessel (RPV) are important for evaluating RPV integrity and emergency procedures. Using existing data, the authors developed heat transfer...
Saved in:
Published in: | Nuclear engineering and design 2003-08, Vol.223 (2), p.145-158 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | For severe accident assessment in a light water reactor, heat transfer models in a narrow annular gap between the overheated core debris and the reactor pressure vessel (RPV) are important for evaluating RPV integrity and emergency procedures. Using existing data, the authors developed heat transfer models on the average critical heat flux (CHF) restricted by countercurrent flow limitation (CCFL) and local boiling heat fluxes, and showed that the average CHF depended on the steam–water flow pattern in the narrow gap and that the local heat fluxes were similar to the pool boiling curve. We evaluated the validity of heat transfer models by simple calculations for ALPHA experiments performed at Japan Atomic Energy Research Institute. Calculated results showed that heat fluxes on the crust surface were restricted mainly by thermal resistance of the crust after the crust formation, and emissivity on the crust surface did not have much effect on the heat fluxes. The calculated vessel temperature during the heat-up process and peak vessel temperature agreed well with the measurements, which confirmed the validity of the average CHF correlation. However, the vessel cooling rate was underestimated mainly due to underestimation of the gap size. |
---|---|
ISSN: | 0029-5493 1872-759X |
DOI: | 10.1016/S0029-5493(03)00040-2 |