Loading…

Clinical efficacy of soft‐tissue augmentation on tissue preservation at immediate implant sites: A randomized controlled trial

Aim This randomized controlled trial aimed to investigate the efficacy of soft‐tissue augmentation (STA) with a subepithelial connective tissue graft (SCTG) or an acellular dermal matrix (ADM) on reducing tissue alterations at an immediate implant site. Materials and Methods This trial had three gro...

Full description

Saved in:
Bibliographic Details
Published in:Journal of clinical periodontology 2023-07, Vol.50 (7), p.1010-1020
Main Authors: Lee, Chun‐Teh, Tran, Duong, Tsukiboshi, Yosuke, Min, Seiko, Kim, Sung K., Ayilavarapu, Srinivas, Weltman, Robin
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Aim This randomized controlled trial aimed to investigate the efficacy of soft‐tissue augmentation (STA) with a subepithelial connective tissue graft (SCTG) or an acellular dermal matrix (ADM) on reducing tissue alterations at an immediate implant site. Materials and Methods This trial had three groups: (i) immediate implant with SCTG (ICT group); (ii) immediate implant with ADM (IAD group); (iii) immediate implant without STA (control group). Forty‐six patients were randomly assigned to each group. Implants were placed at the maxillary anterior or premolar areas and restored after the 6‐month visit. Clinical outcomes, including buccal soft‐tissue contour, peri‐implant mucosal level, soft‐tissue thickness and keratinized tissue width, were measured at baseline and at 3‐, 6‐ and 12‐month follow‐up visits. Radiographic bone levels were measured at baseline and at 6‐ and 12‐month follow‐up visits. Patient‐reported outcomes were also collected. Results STA procedures increased peri‐implant mucosal thickness and maintained buccal soft‐tissue contours. Compared to the control group, STA groups did not prevent peri‐implant mucosal recession or interproximal bone resorption. Generally, no significant differences in clinical outcomes were detected between the ICT and IAD groups. Most patients were highly satisfied with the immediate implant procedure and outcomes without significant differences between groups. Conclusions STA at immediate implant sites enhanced soft‐tissue thickness and maintained soft‐tissue contours but did not prevent peri‐implant mucosal recession or interproximal bone resorption. Long‐term follow‐up should be performed since these results were reported for only up to 1 year.
ISSN:0303-6979
1600-051X
DOI:10.1111/jcpe.13816