Loading…
Effect of the Electrochemical Corrosion Potential of Copper on Plugging of Generator Water-Cooling Circuits
ABSTRACTCopper corrosion-related problems have been frequently reported in the generator water-cooling circuits of both nuclear and thermal power plants operated under the nominally high-oxygen water chemistry (HOWC, dissolved oxygen [DO] >2 ppm) conditions or the nominally low-oxygen water chemi...
Saved in:
Published in: | Corrosion (Houston, Tex.) Tex.), 2005-06, Vol.61 (6), p.559-570 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | ABSTRACTCopper corrosion-related problems have been frequently reported in the generator water-cooling circuits of both nuclear and thermal power plants operated under the nominally high-oxygen water chemistry (HOWC, dissolved oxygen [DO] >2 ppm) conditions or the nominally low-oxygen water chemistry (LOWC, DO |
---|---|
ISSN: | 0010-9312 1938-159X |
DOI: | 10.5006/1.3278191 |