Effect of the Electrochemical Corrosion Potential of Copper on Plugging of Generator Water-Cooling Circuits

ABSTRACTCopper corrosion-related problems have been frequently reported in the generator water-cooling circuits of both nuclear and thermal power plants operated under the nominally high-oxygen water chemistry (HOWC, dissolved oxygen [DO] >2 ppm) conditions or the nominally low-oxygen water chemi...

Full description

Saved in:
Bibliographic Details
Published in:Corrosion (Houston, Tex.) Tex.), 2005-06, Vol.61 (6), p.559-570
Main Authors: Park, B.G., Hwang, I.S., Rhee, I.H., Kim, K.-T., Syrett, B.C., Stein, J.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:ABSTRACTCopper corrosion-related problems have been frequently reported in the generator water-cooling circuits of both nuclear and thermal power plants operated under the nominally high-oxygen water chemistry (HOWC, dissolved oxygen [DO] >2 ppm) conditions or the nominally low-oxygen water chemistry (LOWC, DO
ISSN:0010-9312
1938-159X