Loading…
A review article on the dosimetry in intraluminal HDR brachytherapy of lung carcinoma
Lung cancer is one of the most common cancers in the world. Intraluminal brachytherapy (BT) is one of the most adopted treatment modalities for lung malignancies with Ir-192 source in radiotherapy. In intraluminal BT, treatment delivery is required to be very accurate and precise with respect to the...
Saved in:
Published in: | Journal of cancer research and therapeutics 2023-04, Vol.19 (8), p.36-40 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c404r-a1575de685bb726ee71c1e852d32aa0ff0645660d52e73b75dd774585289aaf73 |
container_end_page | 40 |
container_issue | 8 |
container_start_page | 36 |
container_title | Journal of cancer research and therapeutics |
container_volume | 19 |
creator | Kant, Ravi Gupta, Meenu Bisht, Jyoti Nautiyal, Vipul Kumar, Viney Dobhal, Rishabh Ahmed, Mushtaq Saini, Sunil |
description | Lung cancer is one of the most common cancers in the world. Intraluminal brachytherapy (BT) is one of the most adopted treatment modalities for lung malignancies with Ir-192 source in radiotherapy. In intraluminal BT, treatment delivery is required to be very accurate and precise with respect to the plan created in the treatment planning system (TPS). The BT dosimetry is necessary for better treatment outcomes. Therefore in this review article, some relevant studies were identified and analyzed for dosimetric outcomes in intraluminal BT in lung malignancies. The dosimetry in BT for plan verification is not presently in practice, which needs to be performed to check the variation between the planned and measured doses. The necessary dosimetric work done by the various researchers in intraluminal BT such as the Monte Carlo CYLTRAN code was used to calculate and measure the dose rate in any medium. Anthropomorphic phantom was used to measure doses at some distance from the source with Thermo luminescence dosimeters (TLDs). The dosimetric influence of air passage in the bronchus was evaluated with the GEANT4 Monte Carlo method. A pinpoint chamber was used to measure and quantify the impact of inhomogeneity in wax phantom for the Ir-192 source. The Gafchromic films and Monte Carlo methods were used to find the phantom and heterogeneities, which were found to underestimate the dose for the lungs and overestimated for the bones in TPS. The exact tool to quantify the variation in planned and delivered doses should be cost-effective and easy to use possibly with tissue equivalent phantoms and Gafchromic films in lung malignancies treatment. |
doi_str_mv | 10.4103/jcrt.jcrt_541_22 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2810917360</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2809324173</sourcerecordid><originalsourceid>FETCH-LOGICAL-c404r-a1575de685bb726ee71c1e852d32aa0ff0645660d52e73b75dd774585289aaf73</originalsourceid><addsrcrecordid>eNp10c9rFDEUB_Agit1W754k4MXL1PycZI5L1VYoCGIPnkIm88bONjNZX2Zc9r83625FBCEkl897kO-XkFecXSrO5LtNwPnycDmtuBPiCVnxprGV4tI-JSvWGFlxZcUZOc95w5g2Qtjn5Ewarkxj2YrcrSnCzwF21OM8hAg0TXS-B9qlPIww454OUzkz-riMw-QjvXn_hbbow_2-OPTbPU09jcv0nQaPYZjS6F-QZ72PGV6e3gty9_HD16ub6vbz9aer9W0VFFNYea6N7qC2um2NqAEMDxysFp0U3rO-Z7XSdc06LcDIttjOGKULsI33vZEX5O1x7xbTjwXy7MYhB4jRT5CW7ITlrOFG1qzQN__QTVqw_OegWCOFKq4odlQBU84IvdviMHrcO87cIXL3O-2_Ii8jr0-Ll3aE7s_AY8YFfDuCXYozYH6Iyw7QFfswpd1_FztZu7U7luNO5bg0uRK6eyxH_gLmyJ-S</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2809324173</pqid></control><display><type>article</type><title>A review article on the dosimetry in intraluminal HDR brachytherapy of lung carcinoma</title><source>Publicly Available Content (ProQuest)</source><creator>Kant, Ravi ; Gupta, Meenu ; Bisht, Jyoti ; Nautiyal, Vipul ; Kumar, Viney ; Dobhal, Rishabh ; Ahmed, Mushtaq ; Saini, Sunil</creator><creatorcontrib>Kant, Ravi ; Gupta, Meenu ; Bisht, Jyoti ; Nautiyal, Vipul ; Kumar, Viney ; Dobhal, Rishabh ; Ahmed, Mushtaq ; Saini, Sunil</creatorcontrib><description>Lung cancer is one of the most common cancers in the world. Intraluminal brachytherapy (BT) is one of the most adopted treatment modalities for lung malignancies with Ir-192 source in radiotherapy. In intraluminal BT, treatment delivery is required to be very accurate and precise with respect to the plan created in the treatment planning system (TPS). The BT dosimetry is necessary for better treatment outcomes. Therefore in this review article, some relevant studies were identified and analyzed for dosimetric outcomes in intraluminal BT in lung malignancies. The dosimetry in BT for plan verification is not presently in practice, which needs to be performed to check the variation between the planned and measured doses. The necessary dosimetric work done by the various researchers in intraluminal BT such as the Monte Carlo CYLTRAN code was used to calculate and measure the dose rate in any medium. Anthropomorphic phantom was used to measure doses at some distance from the source with Thermo luminescence dosimeters (TLDs). The dosimetric influence of air passage in the bronchus was evaluated with the GEANT4 Monte Carlo method. A pinpoint chamber was used to measure and quantify the impact of inhomogeneity in wax phantom for the Ir-192 source. The Gafchromic films and Monte Carlo methods were used to find the phantom and heterogeneities, which were found to underestimate the dose for the lungs and overestimated for the bones in TPS. The exact tool to quantify the variation in planned and delivered doses should be cost-effective and easy to use possibly with tissue equivalent phantoms and Gafchromic films in lung malignancies treatment.</description><identifier>ISSN: 0973-1482</identifier><identifier>EISSN: 1998-4138</identifier><identifier>DOI: 10.4103/jcrt.jcrt_541_22</identifier><identifier>PMID: 37147980</identifier><language>eng</language><publisher>India: Wolters Kluwer India Pvt. Ltd</publisher><subject>Brachytherapy - methods ; Carcinoma ; Computer Simulation ; Dosimetry ; Humans ; Lung ; Lung cancer ; Lung Neoplasms - radiotherapy ; Monte Carlo Method ; Phantoms, Imaging ; Radiation therapy ; Radiometry ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted - methods</subject><ispartof>Journal of cancer research and therapeutics, 2023-04, Vol.19 (8), p.36-40</ispartof><rights>2023. This article is published under (http://creativecommons.org/licenses/by-nc-sa/3.0/) (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c404r-a1575de685bb726ee71c1e852d32aa0ff0645660d52e73b75dd774585289aaf73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2809324173?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25744,27915,27916,37003,37004,44581</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37147980$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kant, Ravi</creatorcontrib><creatorcontrib>Gupta, Meenu</creatorcontrib><creatorcontrib>Bisht, Jyoti</creatorcontrib><creatorcontrib>Nautiyal, Vipul</creatorcontrib><creatorcontrib>Kumar, Viney</creatorcontrib><creatorcontrib>Dobhal, Rishabh</creatorcontrib><creatorcontrib>Ahmed, Mushtaq</creatorcontrib><creatorcontrib>Saini, Sunil</creatorcontrib><title>A review article on the dosimetry in intraluminal HDR brachytherapy of lung carcinoma</title><title>Journal of cancer research and therapeutics</title><addtitle>J Cancer Res Ther</addtitle><description>Lung cancer is one of the most common cancers in the world. Intraluminal brachytherapy (BT) is one of the most adopted treatment modalities for lung malignancies with Ir-192 source in radiotherapy. In intraluminal BT, treatment delivery is required to be very accurate and precise with respect to the plan created in the treatment planning system (TPS). The BT dosimetry is necessary for better treatment outcomes. Therefore in this review article, some relevant studies were identified and analyzed for dosimetric outcomes in intraluminal BT in lung malignancies. The dosimetry in BT for plan verification is not presently in practice, which needs to be performed to check the variation between the planned and measured doses. The necessary dosimetric work done by the various researchers in intraluminal BT such as the Monte Carlo CYLTRAN code was used to calculate and measure the dose rate in any medium. Anthropomorphic phantom was used to measure doses at some distance from the source with Thermo luminescence dosimeters (TLDs). The dosimetric influence of air passage in the bronchus was evaluated with the GEANT4 Monte Carlo method. A pinpoint chamber was used to measure and quantify the impact of inhomogeneity in wax phantom for the Ir-192 source. The Gafchromic films and Monte Carlo methods were used to find the phantom and heterogeneities, which were found to underestimate the dose for the lungs and overestimated for the bones in TPS. The exact tool to quantify the variation in planned and delivered doses should be cost-effective and easy to use possibly with tissue equivalent phantoms and Gafchromic films in lung malignancies treatment.</description><subject>Brachytherapy - methods</subject><subject>Carcinoma</subject><subject>Computer Simulation</subject><subject>Dosimetry</subject><subject>Humans</subject><subject>Lung</subject><subject>Lung cancer</subject><subject>Lung Neoplasms - radiotherapy</subject><subject>Monte Carlo Method</subject><subject>Phantoms, Imaging</subject><subject>Radiation therapy</subject><subject>Radiometry</subject><subject>Radiotherapy Dosage</subject><subject>Radiotherapy Planning, Computer-Assisted - methods</subject><issn>0973-1482</issn><issn>1998-4138</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNp10c9rFDEUB_Agit1W754k4MXL1PycZI5L1VYoCGIPnkIm88bONjNZX2Zc9r83625FBCEkl897kO-XkFecXSrO5LtNwPnycDmtuBPiCVnxprGV4tI-JSvWGFlxZcUZOc95w5g2Qtjn5Ewarkxj2YrcrSnCzwF21OM8hAg0TXS-B9qlPIww454OUzkz-riMw-QjvXn_hbbow_2-OPTbPU09jcv0nQaPYZjS6F-QZ72PGV6e3gty9_HD16ub6vbz9aer9W0VFFNYea6N7qC2um2NqAEMDxysFp0U3rO-Z7XSdc06LcDIttjOGKULsI33vZEX5O1x7xbTjwXy7MYhB4jRT5CW7ITlrOFG1qzQN__QTVqw_OegWCOFKq4odlQBU84IvdviMHrcO87cIXL3O-2_Ii8jr0-Ll3aE7s_AY8YFfDuCXYozYH6Iyw7QFfswpd1_FztZu7U7luNO5bg0uRK6eyxH_gLmyJ-S</recordid><startdate>20230401</startdate><enddate>20230401</enddate><creator>Kant, Ravi</creator><creator>Gupta, Meenu</creator><creator>Bisht, Jyoti</creator><creator>Nautiyal, Vipul</creator><creator>Kumar, Viney</creator><creator>Dobhal, Rishabh</creator><creator>Ahmed, Mushtaq</creator><creator>Saini, Sunil</creator><general>Wolters Kluwer India Pvt. Ltd</general><general>Medknow Publications & Media Pvt. Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>M2O</scope><scope>MBDVC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope></search><sort><creationdate>20230401</creationdate><title>A review article on the dosimetry in intraluminal HDR brachytherapy of lung carcinoma</title><author>Kant, Ravi ; Gupta, Meenu ; Bisht, Jyoti ; Nautiyal, Vipul ; Kumar, Viney ; Dobhal, Rishabh ; Ahmed, Mushtaq ; Saini, Sunil</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c404r-a1575de685bb726ee71c1e852d32aa0ff0645660d52e73b75dd774585289aaf73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Brachytherapy - methods</topic><topic>Carcinoma</topic><topic>Computer Simulation</topic><topic>Dosimetry</topic><topic>Humans</topic><topic>Lung</topic><topic>Lung cancer</topic><topic>Lung Neoplasms - radiotherapy</topic><topic>Monte Carlo Method</topic><topic>Phantoms, Imaging</topic><topic>Radiation therapy</topic><topic>Radiometry</topic><topic>Radiotherapy Dosage</topic><topic>Radiotherapy Planning, Computer-Assisted - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kant, Ravi</creatorcontrib><creatorcontrib>Gupta, Meenu</creatorcontrib><creatorcontrib>Bisht, Jyoti</creatorcontrib><creatorcontrib>Nautiyal, Vipul</creatorcontrib><creatorcontrib>Kumar, Viney</creatorcontrib><creatorcontrib>Dobhal, Rishabh</creatorcontrib><creatorcontrib>Ahmed, Mushtaq</creatorcontrib><creatorcontrib>Saini, Sunil</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest_Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Proquest Research Library</collection><collection>Research Library (Corporate)</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of cancer research and therapeutics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kant, Ravi</au><au>Gupta, Meenu</au><au>Bisht, Jyoti</au><au>Nautiyal, Vipul</au><au>Kumar, Viney</au><au>Dobhal, Rishabh</au><au>Ahmed, Mushtaq</au><au>Saini, Sunil</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A review article on the dosimetry in intraluminal HDR brachytherapy of lung carcinoma</atitle><jtitle>Journal of cancer research and therapeutics</jtitle><addtitle>J Cancer Res Ther</addtitle><date>2023-04-01</date><risdate>2023</risdate><volume>19</volume><issue>8</issue><spage>36</spage><epage>40</epage><pages>36-40</pages><issn>0973-1482</issn><eissn>1998-4138</eissn><abstract>Lung cancer is one of the most common cancers in the world. Intraluminal brachytherapy (BT) is one of the most adopted treatment modalities for lung malignancies with Ir-192 source in radiotherapy. In intraluminal BT, treatment delivery is required to be very accurate and precise with respect to the plan created in the treatment planning system (TPS). The BT dosimetry is necessary for better treatment outcomes. Therefore in this review article, some relevant studies were identified and analyzed for dosimetric outcomes in intraluminal BT in lung malignancies. The dosimetry in BT for plan verification is not presently in practice, which needs to be performed to check the variation between the planned and measured doses. The necessary dosimetric work done by the various researchers in intraluminal BT such as the Monte Carlo CYLTRAN code was used to calculate and measure the dose rate in any medium. Anthropomorphic phantom was used to measure doses at some distance from the source with Thermo luminescence dosimeters (TLDs). The dosimetric influence of air passage in the bronchus was evaluated with the GEANT4 Monte Carlo method. A pinpoint chamber was used to measure and quantify the impact of inhomogeneity in wax phantom for the Ir-192 source. The Gafchromic films and Monte Carlo methods were used to find the phantom and heterogeneities, which were found to underestimate the dose for the lungs and overestimated for the bones in TPS. The exact tool to quantify the variation in planned and delivered doses should be cost-effective and easy to use possibly with tissue equivalent phantoms and Gafchromic films in lung malignancies treatment.</abstract><cop>India</cop><pub>Wolters Kluwer India Pvt. Ltd</pub><pmid>37147980</pmid><doi>10.4103/jcrt.jcrt_541_22</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0973-1482 |
ispartof | Journal of cancer research and therapeutics, 2023-04, Vol.19 (8), p.36-40 |
issn | 0973-1482 1998-4138 |
language | eng |
recordid | cdi_proquest_miscellaneous_2810917360 |
source | Publicly Available Content (ProQuest) |
subjects | Brachytherapy - methods Carcinoma Computer Simulation Dosimetry Humans Lung Lung cancer Lung Neoplasms - radiotherapy Monte Carlo Method Phantoms, Imaging Radiation therapy Radiometry Radiotherapy Dosage Radiotherapy Planning, Computer-Assisted - methods |
title | A review article on the dosimetry in intraluminal HDR brachytherapy of lung carcinoma |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T00%3A01%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20review%20article%20on%20the%20dosimetry%20in%20intraluminal%20HDR%20brachytherapy%20of%20lung%20carcinoma&rft.jtitle=Journal%20of%20cancer%20research%20and%20therapeutics&rft.au=Kant,%20Ravi&rft.date=2023-04-01&rft.volume=19&rft.issue=8&rft.spage=36&rft.epage=40&rft.pages=36-40&rft.issn=0973-1482&rft.eissn=1998-4138&rft_id=info:doi/10.4103/jcrt.jcrt_541_22&rft_dat=%3Cproquest_cross%3E2809324173%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c404r-a1575de685bb726ee71c1e852d32aa0ff0645660d52e73b75dd774585289aaf73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2809324173&rft_id=info:pmid/37147980&rfr_iscdi=true |