Communication: Ferrite Number as a Function of the Larson-Miller Parameter for Austenitic Stainless Weld Metals after Creep Testing
Five different stress levels between 70 and 240 MPa were used together with a range of temperature (550 deg C to 700 deg C) for creep testing on E308H and E316H austenitic stainless steel weld deposits. The test results show that the Ferrite Number (FN) exhibits a linear relationship with the Larson...
Saved in:
Published in: | Metallurgical and materials transactions. A, Physical metallurgy and materials science Physical metallurgy and materials science, 2004-11, Vol.35A (11), p.3631-3633A |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Five different stress levels between 70 and 240 MPa were used together with a range of temperature (550 deg C to 700 deg C) for creep testing on E308H and E316H austenitic stainless steel weld deposits. The test results show that the Ferrite Number (FN) exhibits a linear relationship with the Larson-Miller parameter (LMP) after creep testing. More sigma phase formed in commercial E316H weld deposits than in commercial E308H because of the difference in molybdenum content. |
---|---|