Loading…

A strain rate dependent model with decreasing Young’s Modulus for cortical human bone

In the existing literature, some studies have observed an increase in the elastic modulus of human cortical bone with strain rate, which has been described as a consequence of the viscoelastic properties of the bone. However, these results contradict the findings of other studies, in which an indepe...

Full description

Saved in:
Bibliographic Details
Published in:Biomedical physics & engineering express 2023-09, Vol.9 (5), p.55007
Main Authors: Sánchez-Molina, D, García-Vilana, S, Martínez-Sáez, L, Llumà, J
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c368t-e6ed6877e13fa6bb6ea28df4d3a4626faa26c93d1417a87d1b7238bc3d173c663
cites cdi_FETCH-LOGICAL-c368t-e6ed6877e13fa6bb6ea28df4d3a4626faa26c93d1417a87d1b7238bc3d173c663
container_end_page
container_issue 5
container_start_page 55007
container_title Biomedical physics & engineering express
container_volume 9
creator Sánchez-Molina, D
García-Vilana, S
Martínez-Sáez, L
Llumà, J
description In the existing literature, some studies have observed an increase in the elastic modulus of human cortical bone with strain rate, which has been described as a consequence of the viscoelastic properties of the bone. However, these results contradict the findings of other studies, in which an independence or decrease of the elastic modulus with strain rate is observed, which could be explained by other non-viscoelastic mechanisms. This research studies the dynamic behavior of human cortical bone specimens and investigates their mechanical properties . A full and objective strain rate dependent model is proposed and used to describe the experimental results obtained from uniaxial tensile tests of twenty-one human rib cortical bone specimens from twelve male post mortem human subjects (average age of 68.5 ± 12.3 years). In addition, a general discussion of some families of viscoelastic models is given and the caution with which they should be used when dealing with complex materials such as bone. The main experimental finding is that in the range of strain rate analyzed (ε̇=0.10-0.60), there is a significant decrease in Young's modulus ( ≈ 18 GPa forε̇=0.10s-1and ≈ 8 GPa forε̇=0.50s-1), which is not of viscoelastic origin. Moreover, the most frequently used viscoelastic models analyzed in this study predict how the elastic modulus should not vary markedly with strain rate for small strains. In fact, the observed behavior seems related to the findings of other researchers who observed that the microcraking damage depends on the strain rate in the same sense found in our work. This allows us to interpret the qualitative results as a consequence of the microcracking that takes place within the cortical bone, and not related to viscoelastic effects.
doi_str_mv 10.1088/2057-1976/acd458
format article
fullrecord <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_proquest_miscellaneous_2813555945</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2813555945</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-e6ed6877e13fa6bb6ea28df4d3a4626faa26c93d1417a87d1b7238bc3d173c663</originalsourceid><addsrcrecordid>eNp1kMtKxDAUhoMoKuPsXUl2unA0aZpLlyLeQHGjiKuQJqdaaZOatKg7X8PX80nsMDq40NUJP9-55ENom5IDSpQ6zAiXM1pIcWisy7laQZvLaPXXewNNU3oihFCRCVHwdbTBJBWy4HwT3R3h1EdTexxND9hBB96B73EbHDT4pe4fx9BGMKn2D_g-DP7h8_0j4avghmZIuAoR2xD72poGPw6t8bgMHrbQWmWaBNPvOkG3pyc3x-ezy-uzi-Ojy5llQvUzEOCEkhIoq4woSwEmU67KHTP5eG1lTCZswRzNqTRKOlrKjKnSjolkVgg2QXuLuV0MzwOkXrd1stA0xkMYks4UZZzzIucjShaojSGlCJXuYt2a-KYp0XOjeq5Mz5XphdGxZed7-lC24JYNP_5GYHcB1KHTT2GIfvysLjt41YXmmnBOiNSdq0Zy_w_y381fwj-OCw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2813555945</pqid></control><display><type>article</type><title>A strain rate dependent model with decreasing Young’s Modulus for cortical human bone</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Sánchez-Molina, D ; García-Vilana, S ; Martínez-Sáez, L ; Llumà, J</creator><creatorcontrib>Sánchez-Molina, D ; García-Vilana, S ; Martínez-Sáez, L ; Llumà, J</creatorcontrib><description>In the existing literature, some studies have observed an increase in the elastic modulus of human cortical bone with strain rate, which has been described as a consequence of the viscoelastic properties of the bone. However, these results contradict the findings of other studies, in which an independence or decrease of the elastic modulus with strain rate is observed, which could be explained by other non-viscoelastic mechanisms. This research studies the dynamic behavior of human cortical bone specimens and investigates their mechanical properties . A full and objective strain rate dependent model is proposed and used to describe the experimental results obtained from uniaxial tensile tests of twenty-one human rib cortical bone specimens from twelve male post mortem human subjects (average age of 68.5 ± 12.3 years). In addition, a general discussion of some families of viscoelastic models is given and the caution with which they should be used when dealing with complex materials such as bone. The main experimental finding is that in the range of strain rate analyzed (ε̇=0.10-0.60), there is a significant decrease in Young's modulus ( ≈ 18 GPa forε̇=0.10s-1and ≈ 8 GPa forε̇=0.50s-1), which is not of viscoelastic origin. Moreover, the most frequently used viscoelastic models analyzed in this study predict how the elastic modulus should not vary markedly with strain rate for small strains. In fact, the observed behavior seems related to the findings of other researchers who observed that the microcraking damage depends on the strain rate in the same sense found in our work. This allows us to interpret the qualitative results as a consequence of the microcracking that takes place within the cortical bone, and not related to viscoelastic effects.</description><identifier>ISSN: 2057-1976</identifier><identifier>EISSN: 2057-1976</identifier><identifier>DOI: 10.1088/2057-1976/acd458</identifier><identifier>PMID: 37167955</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Aged ; Aged, 80 and over ; Bone and Bones ; constitutive model ; Cortical Bone ; Elastic Modulus ; Humans ; Male ; Middle Aged ; strain rate dependent materials ; Stress, Mechanical ; tissue characerization ; viscoelasticity</subject><ispartof>Biomedical physics &amp; engineering express, 2023-09, Vol.9 (5), p.55007</ispartof><rights>2023 IOP Publishing Ltd</rights><rights>2023 IOP Publishing Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-e6ed6877e13fa6bb6ea28df4d3a4626faa26c93d1417a87d1b7238bc3d173c663</citedby><cites>FETCH-LOGICAL-c368t-e6ed6877e13fa6bb6ea28df4d3a4626faa26c93d1417a87d1b7238bc3d173c663</cites><orcidid>0000-0002-0671-4106 ; 0000-0001-6594-4406 ; 0000-0002-4982-206X ; 0000-0002-8659-1985</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37167955$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sánchez-Molina, D</creatorcontrib><creatorcontrib>García-Vilana, S</creatorcontrib><creatorcontrib>Martínez-Sáez, L</creatorcontrib><creatorcontrib>Llumà, J</creatorcontrib><title>A strain rate dependent model with decreasing Young’s Modulus for cortical human bone</title><title>Biomedical physics &amp; engineering express</title><addtitle>BPEX</addtitle><addtitle>Biomed. Phys. Eng. Express</addtitle><description>In the existing literature, some studies have observed an increase in the elastic modulus of human cortical bone with strain rate, which has been described as a consequence of the viscoelastic properties of the bone. However, these results contradict the findings of other studies, in which an independence or decrease of the elastic modulus with strain rate is observed, which could be explained by other non-viscoelastic mechanisms. This research studies the dynamic behavior of human cortical bone specimens and investigates their mechanical properties . A full and objective strain rate dependent model is proposed and used to describe the experimental results obtained from uniaxial tensile tests of twenty-one human rib cortical bone specimens from twelve male post mortem human subjects (average age of 68.5 ± 12.3 years). In addition, a general discussion of some families of viscoelastic models is given and the caution with which they should be used when dealing with complex materials such as bone. The main experimental finding is that in the range of strain rate analyzed (ε̇=0.10-0.60), there is a significant decrease in Young's modulus ( ≈ 18 GPa forε̇=0.10s-1and ≈ 8 GPa forε̇=0.50s-1), which is not of viscoelastic origin. Moreover, the most frequently used viscoelastic models analyzed in this study predict how the elastic modulus should not vary markedly with strain rate for small strains. In fact, the observed behavior seems related to the findings of other researchers who observed that the microcraking damage depends on the strain rate in the same sense found in our work. This allows us to interpret the qualitative results as a consequence of the microcracking that takes place within the cortical bone, and not related to viscoelastic effects.</description><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Bone and Bones</subject><subject>constitutive model</subject><subject>Cortical Bone</subject><subject>Elastic Modulus</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>strain rate dependent materials</subject><subject>Stress, Mechanical</subject><subject>tissue characerization</subject><subject>viscoelasticity</subject><issn>2057-1976</issn><issn>2057-1976</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp1kMtKxDAUhoMoKuPsXUl2unA0aZpLlyLeQHGjiKuQJqdaaZOatKg7X8PX80nsMDq40NUJP9-55ENom5IDSpQ6zAiXM1pIcWisy7laQZvLaPXXewNNU3oihFCRCVHwdbTBJBWy4HwT3R3h1EdTexxND9hBB96B73EbHDT4pe4fx9BGMKn2D_g-DP7h8_0j4avghmZIuAoR2xD72poGPw6t8bgMHrbQWmWaBNPvOkG3pyc3x-ezy-uzi-Ojy5llQvUzEOCEkhIoq4woSwEmU67KHTP5eG1lTCZswRzNqTRKOlrKjKnSjolkVgg2QXuLuV0MzwOkXrd1stA0xkMYks4UZZzzIucjShaojSGlCJXuYt2a-KYp0XOjeq5Mz5XphdGxZed7-lC24JYNP_5GYHcB1KHTT2GIfvysLjt41YXmmnBOiNSdq0Zy_w_y381fwj-OCw</recordid><startdate>20230901</startdate><enddate>20230901</enddate><creator>Sánchez-Molina, D</creator><creator>García-Vilana, S</creator><creator>Martínez-Sáez, L</creator><creator>Llumà, J</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-0671-4106</orcidid><orcidid>https://orcid.org/0000-0001-6594-4406</orcidid><orcidid>https://orcid.org/0000-0002-4982-206X</orcidid><orcidid>https://orcid.org/0000-0002-8659-1985</orcidid></search><sort><creationdate>20230901</creationdate><title>A strain rate dependent model with decreasing Young’s Modulus for cortical human bone</title><author>Sánchez-Molina, D ; García-Vilana, S ; Martínez-Sáez, L ; Llumà, J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-e6ed6877e13fa6bb6ea28df4d3a4626faa26c93d1417a87d1b7238bc3d173c663</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Bone and Bones</topic><topic>constitutive model</topic><topic>Cortical Bone</topic><topic>Elastic Modulus</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>strain rate dependent materials</topic><topic>Stress, Mechanical</topic><topic>tissue characerization</topic><topic>viscoelasticity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sánchez-Molina, D</creatorcontrib><creatorcontrib>García-Vilana, S</creatorcontrib><creatorcontrib>Martínez-Sáez, L</creatorcontrib><creatorcontrib>Llumà, J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Biomedical physics &amp; engineering express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sánchez-Molina, D</au><au>García-Vilana, S</au><au>Martínez-Sáez, L</au><au>Llumà, J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A strain rate dependent model with decreasing Young’s Modulus for cortical human bone</atitle><jtitle>Biomedical physics &amp; engineering express</jtitle><stitle>BPEX</stitle><addtitle>Biomed. Phys. Eng. Express</addtitle><date>2023-09-01</date><risdate>2023</risdate><volume>9</volume><issue>5</issue><spage>55007</spage><pages>55007-</pages><issn>2057-1976</issn><eissn>2057-1976</eissn><abstract>In the existing literature, some studies have observed an increase in the elastic modulus of human cortical bone with strain rate, which has been described as a consequence of the viscoelastic properties of the bone. However, these results contradict the findings of other studies, in which an independence or decrease of the elastic modulus with strain rate is observed, which could be explained by other non-viscoelastic mechanisms. This research studies the dynamic behavior of human cortical bone specimens and investigates their mechanical properties . A full and objective strain rate dependent model is proposed and used to describe the experimental results obtained from uniaxial tensile tests of twenty-one human rib cortical bone specimens from twelve male post mortem human subjects (average age of 68.5 ± 12.3 years). In addition, a general discussion of some families of viscoelastic models is given and the caution with which they should be used when dealing with complex materials such as bone. The main experimental finding is that in the range of strain rate analyzed (ε̇=0.10-0.60), there is a significant decrease in Young's modulus ( ≈ 18 GPa forε̇=0.10s-1and ≈ 8 GPa forε̇=0.50s-1), which is not of viscoelastic origin. Moreover, the most frequently used viscoelastic models analyzed in this study predict how the elastic modulus should not vary markedly with strain rate for small strains. In fact, the observed behavior seems related to the findings of other researchers who observed that the microcraking damage depends on the strain rate in the same sense found in our work. This allows us to interpret the qualitative results as a consequence of the microcracking that takes place within the cortical bone, and not related to viscoelastic effects.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>37167955</pmid><doi>10.1088/2057-1976/acd458</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0002-0671-4106</orcidid><orcidid>https://orcid.org/0000-0001-6594-4406</orcidid><orcidid>https://orcid.org/0000-0002-4982-206X</orcidid><orcidid>https://orcid.org/0000-0002-8659-1985</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2057-1976
ispartof Biomedical physics & engineering express, 2023-09, Vol.9 (5), p.55007
issn 2057-1976
2057-1976
language eng
recordid cdi_proquest_miscellaneous_2813555945
source Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)
subjects Aged
Aged, 80 and over
Bone and Bones
constitutive model
Cortical Bone
Elastic Modulus
Humans
Male
Middle Aged
strain rate dependent materials
Stress, Mechanical
tissue characerization
viscoelasticity
title A strain rate dependent model with decreasing Young’s Modulus for cortical human bone
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T23%3A42%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20strain%20rate%20dependent%20model%20with%20decreasing%20Young%E2%80%99s%20Modulus%20for%20cortical%20human%20bone&rft.jtitle=Biomedical%20physics%20&%20engineering%20express&rft.au=S%C3%A1nchez-Molina,%20D&rft.date=2023-09-01&rft.volume=9&rft.issue=5&rft.spage=55007&rft.pages=55007-&rft.issn=2057-1976&rft.eissn=2057-1976&rft_id=info:doi/10.1088/2057-1976/acd458&rft_dat=%3Cproquest_iop_j%3E2813555945%3C/proquest_iop_j%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c368t-e6ed6877e13fa6bb6ea28df4d3a4626faa26c93d1417a87d1b7238bc3d173c663%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2813555945&rft_id=info:pmid/37167955&rfr_iscdi=true