Loading…
Observer-based direct field orientation: analysis and comparison of alternative methods
This paper focuses on methods of achieving direct field orientation (DFO) of induction machines based on closed-loop, stator, and rotor flux observers which are well suited to both zero and very high-speed operation. Both observer topologies are dominated by a current model at zero and low speeds, a...
Saved in:
Published in: | IEEE transactions on industry applications 1994-07, Vol.30 (4), p.945-953 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c343t-c12869a09ffc9d2ec7c942cfa702d88fe9069ec622153027e3c05d3852ac97803 |
---|---|
cites | cdi_FETCH-LOGICAL-c343t-c12869a09ffc9d2ec7c942cfa702d88fe9069ec622153027e3c05d3852ac97803 |
container_end_page | 953 |
container_issue | 4 |
container_start_page | 945 |
container_title | IEEE transactions on industry applications |
container_volume | 30 |
creator | Jansen, P.L. Lorenz, R.D. Novotny, D.W. |
description | This paper focuses on methods of achieving direct field orientation (DFO) of induction machines based on closed-loop, stator, and rotor flux observers which are well suited to both zero and very high-speed operation. Both observer topologies are dominated by a current model at zero and low speeds, and a voltage model at high speeds. Application of such rotor and stator flux observers to both stator and rotor direct field orientation is presented, including experimental results for three different methods. The influence which flux regulation has on parameter sensitivity of the complete DFO system is analyzed. A rotor-flux-regulated and -oriented system is shown to be sensitive to leakage inductance under high slip (i.e., field weakened) operation. Both a stator-flux-regulated and -oriented system and a stator-flux-regulated, rotor-flux-oriented system are shown to have reduced parameter sensitivity at high speeds. Unlike stator flux orientation using simple voltage integration stator flux models, excellent zero and low-speed operation of an observer-based stator-flux-oriented system is demonstrated.< > |
doi_str_mv | 10.1109/28.297911 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_28190527</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>297911</ieee_id><sourcerecordid>28190527</sourcerecordid><originalsourceid>FETCH-LOGICAL-c343t-c12869a09ffc9d2ec7c942cfa702d88fe9069ec622153027e3c05d3852ac97803</originalsourceid><addsrcrecordid>eNqF0DtLBDEQwPEgCp6nha1VKsFiNY99ZOzk8AUH1yiWSy6ZYGR3cya5g_v2ruxhazUD82OKPyGXnN1yzuBOqFsBDXB-RGYcJBQg6-aYzBgDWQBAeUrOUvpijJcVL2fkY7VOGHcYi7VOaKn1EU2mzmNnaYgeh6yzD8M91YPu9smncbHUhH6jo09hoMFR3WWMw-h2SHvMn8Gmc3LidJfw4jDn5P3p8W3xUixXz6-Lh2VhZClzYbhQNWgGzhmwAk1joBTG6YYJq5RDYDWgqYXglWSiQWlYZaWqhDbQKCbn5Hr6u4nhe4spt71PBrtODxi2qRVjCmAK_odqdJVoRngzQRNDShFdu4m-13Hfctb-Nh5pOzUe7dVkPSL-ucPxB603dzU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28190527</pqid></control><display><type>article</type><title>Observer-based direct field orientation: analysis and comparison of alternative methods</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Jansen, P.L. ; Lorenz, R.D. ; Novotny, D.W.</creator><creatorcontrib>Jansen, P.L. ; Lorenz, R.D. ; Novotny, D.W.</creatorcontrib><description>This paper focuses on methods of achieving direct field orientation (DFO) of induction machines based on closed-loop, stator, and rotor flux observers which are well suited to both zero and very high-speed operation. Both observer topologies are dominated by a current model at zero and low speeds, and a voltage model at high speeds. Application of such rotor and stator flux observers to both stator and rotor direct field orientation is presented, including experimental results for three different methods. The influence which flux regulation has on parameter sensitivity of the complete DFO system is analyzed. A rotor-flux-regulated and -oriented system is shown to be sensitive to leakage inductance under high slip (i.e., field weakened) operation. Both a stator-flux-regulated and -oriented system and a stator-flux-regulated, rotor-flux-oriented system are shown to have reduced parameter sensitivity at high speeds. Unlike stator flux orientation using simple voltage integration stator flux models, excellent zero and low-speed operation of an observer-based stator-flux-oriented system is demonstrated.< ></description><identifier>ISSN: 0093-9994</identifier><identifier>EISSN: 1939-9367</identifier><identifier>DOI: 10.1109/28.297911</identifier><identifier>CODEN: ITIACR</identifier><language>eng</language><publisher>IEEE</publisher><subject>Electric machines ; Inductance ; Induction machines ; Industry Applications Society ; Network servers ; Rotors ; Shafts ; Stators ; Torque control ; Voltage</subject><ispartof>IEEE transactions on industry applications, 1994-07, Vol.30 (4), p.945-953</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c343t-c12869a09ffc9d2ec7c942cfa702d88fe9069ec622153027e3c05d3852ac97803</citedby><cites>FETCH-LOGICAL-c343t-c12869a09ffc9d2ec7c942cfa702d88fe9069ec622153027e3c05d3852ac97803</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/297911$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27923,27924,54795</link.rule.ids></links><search><creatorcontrib>Jansen, P.L.</creatorcontrib><creatorcontrib>Lorenz, R.D.</creatorcontrib><creatorcontrib>Novotny, D.W.</creatorcontrib><title>Observer-based direct field orientation: analysis and comparison of alternative methods</title><title>IEEE transactions on industry applications</title><addtitle>TIA</addtitle><description>This paper focuses on methods of achieving direct field orientation (DFO) of induction machines based on closed-loop, stator, and rotor flux observers which are well suited to both zero and very high-speed operation. Both observer topologies are dominated by a current model at zero and low speeds, and a voltage model at high speeds. Application of such rotor and stator flux observers to both stator and rotor direct field orientation is presented, including experimental results for three different methods. The influence which flux regulation has on parameter sensitivity of the complete DFO system is analyzed. A rotor-flux-regulated and -oriented system is shown to be sensitive to leakage inductance under high slip (i.e., field weakened) operation. Both a stator-flux-regulated and -oriented system and a stator-flux-regulated, rotor-flux-oriented system are shown to have reduced parameter sensitivity at high speeds. Unlike stator flux orientation using simple voltage integration stator flux models, excellent zero and low-speed operation of an observer-based stator-flux-oriented system is demonstrated.< ></description><subject>Electric machines</subject><subject>Inductance</subject><subject>Induction machines</subject><subject>Industry Applications Society</subject><subject>Network servers</subject><subject>Rotors</subject><subject>Shafts</subject><subject>Stators</subject><subject>Torque control</subject><subject>Voltage</subject><issn>0093-9994</issn><issn>1939-9367</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNqF0DtLBDEQwPEgCp6nha1VKsFiNY99ZOzk8AUH1yiWSy6ZYGR3cya5g_v2ruxhazUD82OKPyGXnN1yzuBOqFsBDXB-RGYcJBQg6-aYzBgDWQBAeUrOUvpijJcVL2fkY7VOGHcYi7VOaKn1EU2mzmNnaYgeh6yzD8M91YPu9smncbHUhH6jo09hoMFR3WWMw-h2SHvMn8Gmc3LidJfw4jDn5P3p8W3xUixXz6-Lh2VhZClzYbhQNWgGzhmwAk1joBTG6YYJq5RDYDWgqYXglWSiQWlYZaWqhDbQKCbn5Hr6u4nhe4spt71PBrtODxi2qRVjCmAK_odqdJVoRngzQRNDShFdu4m-13Hfctb-Nh5pOzUe7dVkPSL-ucPxB603dzU</recordid><startdate>19940701</startdate><enddate>19940701</enddate><creator>Jansen, P.L.</creator><creator>Lorenz, R.D.</creator><creator>Novotny, D.W.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope><scope>7TB</scope><scope>FR3</scope></search><sort><creationdate>19940701</creationdate><title>Observer-based direct field orientation: analysis and comparison of alternative methods</title><author>Jansen, P.L. ; Lorenz, R.D. ; Novotny, D.W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c343t-c12869a09ffc9d2ec7c942cfa702d88fe9069ec622153027e3c05d3852ac97803</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Electric machines</topic><topic>Inductance</topic><topic>Induction machines</topic><topic>Industry Applications Society</topic><topic>Network servers</topic><topic>Rotors</topic><topic>Shafts</topic><topic>Stators</topic><topic>Torque control</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jansen, P.L.</creatorcontrib><creatorcontrib>Lorenz, R.D.</creatorcontrib><creatorcontrib>Novotny, D.W.</creatorcontrib><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Engineering Research Database</collection><jtitle>IEEE transactions on industry applications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jansen, P.L.</au><au>Lorenz, R.D.</au><au>Novotny, D.W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Observer-based direct field orientation: analysis and comparison of alternative methods</atitle><jtitle>IEEE transactions on industry applications</jtitle><stitle>TIA</stitle><date>1994-07-01</date><risdate>1994</risdate><volume>30</volume><issue>4</issue><spage>945</spage><epage>953</epage><pages>945-953</pages><issn>0093-9994</issn><eissn>1939-9367</eissn><coden>ITIACR</coden><abstract>This paper focuses on methods of achieving direct field orientation (DFO) of induction machines based on closed-loop, stator, and rotor flux observers which are well suited to both zero and very high-speed operation. Both observer topologies are dominated by a current model at zero and low speeds, and a voltage model at high speeds. Application of such rotor and stator flux observers to both stator and rotor direct field orientation is presented, including experimental results for three different methods. The influence which flux regulation has on parameter sensitivity of the complete DFO system is analyzed. A rotor-flux-regulated and -oriented system is shown to be sensitive to leakage inductance under high slip (i.e., field weakened) operation. Both a stator-flux-regulated and -oriented system and a stator-flux-regulated, rotor-flux-oriented system are shown to have reduced parameter sensitivity at high speeds. Unlike stator flux orientation using simple voltage integration stator flux models, excellent zero and low-speed operation of an observer-based stator-flux-oriented system is demonstrated.< ></abstract><pub>IEEE</pub><doi>10.1109/28.297911</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0093-9994 |
ispartof | IEEE transactions on industry applications, 1994-07, Vol.30 (4), p.945-953 |
issn | 0093-9994 1939-9367 |
language | eng |
recordid | cdi_proquest_miscellaneous_28190527 |
source | IEEE Electronic Library (IEL) Journals |
subjects | Electric machines Inductance Induction machines Industry Applications Society Network servers Rotors Shafts Stators Torque control Voltage |
title | Observer-based direct field orientation: analysis and comparison of alternative methods |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T05%3A28%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Observer-based%20direct%20field%20orientation:%20analysis%20and%20comparison%20of%20alternative%20methods&rft.jtitle=IEEE%20transactions%20on%20industry%20applications&rft.au=Jansen,%20P.L.&rft.date=1994-07-01&rft.volume=30&rft.issue=4&rft.spage=945&rft.epage=953&rft.pages=945-953&rft.issn=0093-9994&rft.eissn=1939-9367&rft.coden=ITIACR&rft_id=info:doi/10.1109/28.297911&rft_dat=%3Cproquest_cross%3E28190527%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c343t-c12869a09ffc9d2ec7c942cfa702d88fe9069ec622153027e3c05d3852ac97803%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=28190527&rft_id=info:pmid/&rft_ieee_id=297911&rfr_iscdi=true |