Luminescent ratiometric method in the frequency domain with dual phase-shift measurements: Application to oxygen sensing

A novel ratiometric method for luminescence measurements in the frequency domain is presented. The method is based on the large difference between the lifetimes of the phosphorescence and fluorescence emissions of a dual luminescent indicator. The intensity ratios long-lived/short-lived emission is...

Full description

Saved in:
Bibliographic Details
Published in:Sensors and actuators. B, Chemical Chemical, 2006-09, Vol.117 (1), p.266-273
Main Authors: Valledor, Marta, Campo, Juan Carlos, Sánchez-Barragán, Israel, Viera, Juan Carlos, Costa-Fernández, José M., Sanz-Medel, Alfredo
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A novel ratiometric method for luminescence measurements in the frequency domain is presented. The method is based on the large difference between the lifetimes of the phosphorescence and fluorescence emissions of a dual luminescent indicator. The intensity ratios long-lived/short-lived emission is calculated by measuring the phase shift between the excitation and emission signals at two different but close frequencies. Ratiometric measurements are preferred to alternative luminescent measurements due to their proved insensitivity to ambient or scattered light, instrumental fluctuations, etc. Thus, they can be applied to the development of robust luminescence optical sensors. Theoretical aspects of the new methodology proposed here, the design and construction of a fiber-optic measuring prototype system using low-cost optoelectronics, including a light emitting diode (LED) to excite the chemical sensor and a conventional photodiode to measure the luminescent emission, is presented. The drive of the LED to obtain a good ratiometric measurement is also discussed. The performance of the proposed measurement method and simple instrument has been assessed using an oxygen sensing phase prepared by immobilizing Al-Ferron in an inorganic sol–gel support. This oxygen sensitive indicator shows a strong oxygen-insensitive fluorescence emission overlapping significantly with a long-lifetime oxygen-dependent phosphorescence emission. As compared to other ratiometric approaches, the method here proposed requires only one optical path to measure the luminescent response and luminophors showing only emission intensity changes in response to a certain analyte can be used, since changes in lifetime are not required. Interestingly, the ratiometric method can even be used without losing accuracy even if a spectral overlap between the two measured emissions occurs.
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2005.11.043