Loading…
Generic operational characteristics of piezoelectric transformers
The universal attributes of piezoelectric transformers (PT) were derived by an approximate analysis that yielded closed form equations relating the normalized load resistance to the voltage gain, output power per unit and efficiency. Based on the results of the study, a calculation procedure is deve...
Saved in:
Published in: | IEEE transactions on power electronics 2002-11, Vol.17 (6), p.1049-1057 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c417t-c88b1f6f8e3855ddae55e16dd097086d4e77498d5b24e6830206d86eb42ff673 |
---|---|
cites | cdi_FETCH-LOGICAL-c417t-c88b1f6f8e3855ddae55e16dd097086d4e77498d5b24e6830206d86eb42ff673 |
container_end_page | 1057 |
container_issue | 6 |
container_start_page | 1049 |
container_title | IEEE transactions on power electronics |
container_volume | 17 |
creator | Ivensky, G. Zafrany, I. Ben-Yaakov, S. |
description | The universal attributes of piezoelectric transformers (PT) were derived by an approximate analysis that yielded closed form equations relating the normalized load resistance to the voltage gain, output power per unit and efficiency. Based on the results of the study, a calculation procedure is developed for specifying a PT for any given application and is demonstrated by considering the design of a fluorescent lamp driver. It is suggested that the closed form formulae, developed in this study, could be invaluable when studying, specifying and designing practical PTs applications. |
doi_str_mv | 10.1109/TPEL.2002.805602 |
format | article |
fullrecord | <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_proquest_miscellaneous_28324221</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1158996</ieee_id><sourcerecordid>28324221</sourcerecordid><originalsourceid>FETCH-LOGICAL-c417t-c88b1f6f8e3855ddae55e16dd097086d4e77498d5b24e6830206d86eb42ff673</originalsourceid><addsrcrecordid>eNp90M9LwzAUwPEgCs7pXfBSPOip8yVN0uQ4xvwBAz3sHrL0FTu6pibdQf96UyoIHjw9eHzeO3wJuaawoBT0w_ZtvVkwALZQICSwEzKjmtMcKJSnZAZKiVxpXZyTixj3AJQLoDOyfMIOQ-My32OwQ-M722bu3QbrhrSPQ-Ni5uusb_DLY4tuGPEQbBdrHw4Y4iU5q20b8epnzsn2cb1dPeeb16eX1XKTO07LIXdK7Wgta4WFEqKqLAqBVFYV6BKUrDiWJdeqEjvGUaoCGMhKSdxxVteyLObkfnrbB_9xxDiYQxMdtq3t0B-j0VBqoZjkSd79K5kqGGeMJnj7B-79MaQAyYCUmjOhEoIJueBjDFibPjQHGz4NBTOWN2N5M5Y3U_l0cjOdNIj4y6lI_WXxDYiYfvc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>206694258</pqid></control><display><type>article</type><title>Generic operational characteristics of piezoelectric transformers</title><source>IEEE Xplore (Online service)</source><creator>Ivensky, G. ; Zafrany, I. ; Ben-Yaakov, S.</creator><creatorcontrib>Ivensky, G. ; Zafrany, I. ; Ben-Yaakov, S.</creatorcontrib><description>The universal attributes of piezoelectric transformers (PT) were derived by an approximate analysis that yielded closed form equations relating the normalized load resistance to the voltage gain, output power per unit and efficiency. Based on the results of the study, a calculation procedure is developed for specifying a PT for any given application and is demonstrated by considering the design of a fluorescent lamp driver. It is suggested that the closed form formulae, developed in this study, could be invaluable when studying, specifying and designing practical PTs applications.</description><identifier>ISSN: 0885-8993</identifier><identifier>EISSN: 1941-0107</identifier><identifier>DOI: 10.1109/TPEL.2002.805602</identifier><identifier>CODEN: ITPEE8</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Application software ; Approximation ; Capacitance ; Computational efficiency ; Drivers ; Electronics ; Equations ; Equivalent circuits ; Exact solutions ; Fluorescent lamps ; Mathematical analysis ; Piezoelectricity ; Power ; Power electronics ; Power generation ; Resonant frequency ; Transformers ; Voltage ; Voltage gain</subject><ispartof>IEEE transactions on power electronics, 2002-11, Vol.17 (6), p.1049-1057</ispartof><rights>Copyright Institute of Electrical and Electronics Engineers, Inc. (IEEE) Nov 2002</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c417t-c88b1f6f8e3855ddae55e16dd097086d4e77498d5b24e6830206d86eb42ff673</citedby><cites>FETCH-LOGICAL-c417t-c88b1f6f8e3855ddae55e16dd097086d4e77498d5b24e6830206d86eb42ff673</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1158996$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,777,781,27905,27906,54777</link.rule.ids></links><search><creatorcontrib>Ivensky, G.</creatorcontrib><creatorcontrib>Zafrany, I.</creatorcontrib><creatorcontrib>Ben-Yaakov, S.</creatorcontrib><title>Generic operational characteristics of piezoelectric transformers</title><title>IEEE transactions on power electronics</title><addtitle>TPEL</addtitle><description>The universal attributes of piezoelectric transformers (PT) were derived by an approximate analysis that yielded closed form equations relating the normalized load resistance to the voltage gain, output power per unit and efficiency. Based on the results of the study, a calculation procedure is developed for specifying a PT for any given application and is demonstrated by considering the design of a fluorescent lamp driver. It is suggested that the closed form formulae, developed in this study, could be invaluable when studying, specifying and designing practical PTs applications.</description><subject>Application software</subject><subject>Approximation</subject><subject>Capacitance</subject><subject>Computational efficiency</subject><subject>Drivers</subject><subject>Electronics</subject><subject>Equations</subject><subject>Equivalent circuits</subject><subject>Exact solutions</subject><subject>Fluorescent lamps</subject><subject>Mathematical analysis</subject><subject>Piezoelectricity</subject><subject>Power</subject><subject>Power electronics</subject><subject>Power generation</subject><subject>Resonant frequency</subject><subject>Transformers</subject><subject>Voltage</subject><subject>Voltage gain</subject><issn>0885-8993</issn><issn>1941-0107</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNp90M9LwzAUwPEgCs7pXfBSPOip8yVN0uQ4xvwBAz3sHrL0FTu6pibdQf96UyoIHjw9eHzeO3wJuaawoBT0w_ZtvVkwALZQICSwEzKjmtMcKJSnZAZKiVxpXZyTixj3AJQLoDOyfMIOQ-My32OwQ-M722bu3QbrhrSPQ-Ni5uusb_DLY4tuGPEQbBdrHw4Y4iU5q20b8epnzsn2cb1dPeeb16eX1XKTO07LIXdK7Wgta4WFEqKqLAqBVFYV6BKUrDiWJdeqEjvGUaoCGMhKSdxxVteyLObkfnrbB_9xxDiYQxMdtq3t0B-j0VBqoZjkSd79K5kqGGeMJnj7B-79MaQAyYCUmjOhEoIJueBjDFibPjQHGz4NBTOWN2N5M5Y3U_l0cjOdNIj4y6lI_WXxDYiYfvc</recordid><startdate>20021101</startdate><enddate>20021101</enddate><creator>Ivensky, G.</creator><creator>Zafrany, I.</creator><creator>Ben-Yaakov, S.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>F28</scope></search><sort><creationdate>20021101</creationdate><title>Generic operational characteristics of piezoelectric transformers</title><author>Ivensky, G. ; Zafrany, I. ; Ben-Yaakov, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c417t-c88b1f6f8e3855ddae55e16dd097086d4e77498d5b24e6830206d86eb42ff673</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Application software</topic><topic>Approximation</topic><topic>Capacitance</topic><topic>Computational efficiency</topic><topic>Drivers</topic><topic>Electronics</topic><topic>Equations</topic><topic>Equivalent circuits</topic><topic>Exact solutions</topic><topic>Fluorescent lamps</topic><topic>Mathematical analysis</topic><topic>Piezoelectricity</topic><topic>Power</topic><topic>Power electronics</topic><topic>Power generation</topic><topic>Resonant frequency</topic><topic>Transformers</topic><topic>Voltage</topic><topic>Voltage gain</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ivensky, G.</creatorcontrib><creatorcontrib>Zafrany, I.</creatorcontrib><creatorcontrib>Ben-Yaakov, S.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 1998–Present</collection><collection>IEEE Xplore</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><jtitle>IEEE transactions on power electronics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ivensky, G.</au><au>Zafrany, I.</au><au>Ben-Yaakov, S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Generic operational characteristics of piezoelectric transformers</atitle><jtitle>IEEE transactions on power electronics</jtitle><stitle>TPEL</stitle><date>2002-11-01</date><risdate>2002</risdate><volume>17</volume><issue>6</issue><spage>1049</spage><epage>1057</epage><pages>1049-1057</pages><issn>0885-8993</issn><eissn>1941-0107</eissn><coden>ITPEE8</coden><abstract>The universal attributes of piezoelectric transformers (PT) were derived by an approximate analysis that yielded closed form equations relating the normalized load resistance to the voltage gain, output power per unit and efficiency. Based on the results of the study, a calculation procedure is developed for specifying a PT for any given application and is demonstrated by considering the design of a fluorescent lamp driver. It is suggested that the closed form formulae, developed in this study, could be invaluable when studying, specifying and designing practical PTs applications.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TPEL.2002.805602</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0885-8993 |
ispartof | IEEE transactions on power electronics, 2002-11, Vol.17 (6), p.1049-1057 |
issn | 0885-8993 1941-0107 |
language | eng |
recordid | cdi_proquest_miscellaneous_28324221 |
source | IEEE Xplore (Online service) |
subjects | Application software Approximation Capacitance Computational efficiency Drivers Electronics Equations Equivalent circuits Exact solutions Fluorescent lamps Mathematical analysis Piezoelectricity Power Power electronics Power generation Resonant frequency Transformers Voltage Voltage gain |
title | Generic operational characteristics of piezoelectric transformers |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T12%3A00%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Generic%20operational%20characteristics%20of%20piezoelectric%20transformers&rft.jtitle=IEEE%20transactions%20on%20power%20electronics&rft.au=Ivensky,%20G.&rft.date=2002-11-01&rft.volume=17&rft.issue=6&rft.spage=1049&rft.epage=1057&rft.pages=1049-1057&rft.issn=0885-8993&rft.eissn=1941-0107&rft.coden=ITPEE8&rft_id=info:doi/10.1109/TPEL.2002.805602&rft_dat=%3Cproquest_ieee_%3E28324221%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c417t-c88b1f6f8e3855ddae55e16dd097086d4e77498d5b24e6830206d86eb42ff673%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=206694258&rft_id=info:pmid/&rft_ieee_id=1158996&rfr_iscdi=true |