Loading…

Can We Accurately Predict Critical Power and W′ from a Single Ramp Incremental Exercise Test?

The purpose of this study was to examine the suitability of a single ramp incremental test to predict critical power (CP) and W' . We hypothesized that CP would correspond to the corrected power output (PO) at the respiratory compensation point (RCP) and W' would be calculable from the wor...

Full description

Saved in:
Bibliographic Details
Published in:Medicine and science in sports and exercise 2023-08, Vol.55 (8), p.1401-1408
Main Authors: CAEN, KEVIN, BOURGOIS, JAN G., STUER, LENA, MERMANS, VINCENT, BOONE, JAN
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The purpose of this study was to examine the suitability of a single ramp incremental test to predict critical power (CP) and W' . We hypothesized that CP would correspond to the corrected power output (PO) at the respiratory compensation point (RCP) and W' would be calculable from the work done above RCP. One hundred fifty-three healthy young people (26 ± 4 yr, 51.4 ± 7.6 mL·min -1 ·kg -1 ) performed a maximal ramp test (20, 25, or 30 W·min -1 ), followed by three to five constant load trials to determine CP and W' . CP and W' were estimated using a "best individual fit" approach, selecting the mathematical model with the smallest total error. The RCP was identified by means of gas exchange analysis and then translated into its appropriate PO by applying a correction strategy in order to account for the gap in the V̇O 2 /PO relationship between ramp and constant load exercise. We evaluated the agreement between CP and the PO at RCP, and between W' and the total work done above CP ( W'RAMP > CP ) and above RCP ( W'RAMP > RCP ) during the ramp test. The CP was significantly higher than the PO at RCP (Δ = 8 ± 16 W, P < 0.001). W'RAMP > CP was significantly lower than W' (Δ = 1.9 ± 3.3 kJ, P < 0.001), whereas W'RAMP > RCP and W' did not differ from each other (Δ = -0.6 ± 5.8 kJ, P = 0.21). Despite the fact that CP and RCP occurred in close proximity, the estimation of W' from ramp exercise may be problematic given the likelihood of underestimation and considering the large variability. Therefore, we do not recommend the interchangeable use of CP and W' values derived from constant load versus ramp exercise, in particular, when the goal is to obtain accurate estimates or to predict performance capacity.
ISSN:0195-9131
1530-0315
DOI:10.1249/MSS.0000000000003171