Study of 1-3 composite transducer for ultrasonic wirebonding application
Lead zirconate titanate (PZT)/epoxy 1-3 composites consisted of PZT rods embedded in an epoxy matrix were used as the driving elements in an ultrasonic wirebonding transducer for microelectronic packaging. The performance of the 1-3 composite PZT transducer with 0.91 volume fraction of PZT has been...
Saved in:
Published in: | Ceramics international 2004, Vol.30 (7), p.1141-1146 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Lead zirconate titanate (PZT)/epoxy 1-3 composites consisted of PZT rods embedded in an epoxy matrix were used as the driving elements in an ultrasonic wirebonding transducer for microelectronic packaging. The performance of the 1-3 composite PZT transducer with 0.91 volume fraction of PZT has been studied. The composite transducer has fewer lateral vibrations and higher damping. It has the potential to be used in new generation high-speed and fine-pitch ultrasonic wirebonding machines. |
---|---|
ISSN: | 0272-8842 1873-3956 |
DOI: | 10.1016/j.ceramint.2003.12.013 |