Loading…

A new approach to the arcing faults detection for fast autoreclosure in transmission systems

To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior i...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on power delivery 1995-10, Vol.10 (4), p.1793-1798
Main Authors: Djuric, M.B., Terzija, V.V.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153
cites cdi_FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153
container_end_page 1798
container_issue 4
container_start_page 1793
container_title IEEE transactions on power delivery
container_volume 10
creator Djuric, M.B.
Terzija, V.V.
description To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior influences other voltages and currents distorting them, offered an opportunity to detect the arc by measuring and processing the transmission line terminal voltage and current. A series of simulation studies have shown that the algorithm can be used as an effective tool for arcing faults detection.< >
doi_str_mv 10.1109/61.473378
format article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_proquest_miscellaneous_28496908</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>473378</ieee_id><sourcerecordid>28496908</sourcerecordid><originalsourceid>FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153</originalsourceid><addsrcrecordid>eNo9kM1LxDAQxYMouK4evHrKQQQPXZOmbZLjIn7Bghe9CSWdTtxKt10zKbL_vV267Glg5vce8x5j11IspBT2oZCLTCulzQmbSat0kqXCnLKZMCZPjNX6nF0Q_QghMmHFjH0teYd_3G23oXew5rHncY3cBWi6b-7d0EbiNUaE2PQd930YlxS5G2IfENqehoC86XgMrqNNQ7THaEcRN3TJzrxrCa8Oc84-n58-Hl-T1fvL2-NylYBSaUxQaOEVACrv6iot6jzPTFZYWYGUJqtMakylCwtVUXuPCFbnVtaZsjkAyFzN2d3kO4b4HZBiOT4C2Lauw36gMjWZLawwI3g_gRB6ooC-3IZm48KulKLc91cWspz6G9nbg6kjcK0f80FDR0FqrBgVI3YzYQ0iHq8Hj397fHjx</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28496908</pqid></control><display><type>article</type><title>A new approach to the arcing faults detection for fast autoreclosure in transmission systems</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Djuric, M.B. ; Terzija, V.V.</creator><creatorcontrib>Djuric, M.B. ; Terzija, V.V.</creatorcontrib><description>To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior influences other voltages and currents distorting them, offered an opportunity to detect the arc by measuring and processing the transmission line terminal voltage and current. A series of simulation studies have shown that the algorithm can be used as an effective tool for arcing faults detection.&lt; &gt;</description><identifier>ISSN: 0885-8977</identifier><identifier>EISSN: 1937-4208</identifier><identifier>DOI: 10.1109/61.473378</identifier><identifier>CODEN: ITPDE5</identifier><language>eng</language><publisher>New York, NY: IEEE</publisher><subject>Algorithm design and analysis ; Applied sciences ; Current measurement ; Distortion measurement ; Disturbances. Regulation. Protection ; Electrical engineering. Electrical power engineering ; Electrical fault detection ; Electrical power engineering ; Exact sciences and technology ; Fault detection ; Nonlinear distortion ; Power networks and lines ; Power transmission ; Power transmission lines ; Transmission line measurements ; Voltage</subject><ispartof>IEEE transactions on power delivery, 1995-10, Vol.10 (4), p.1793-1798</ispartof><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153</citedby><cites>FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/473378$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925,54796</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2890110$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Djuric, M.B.</creatorcontrib><creatorcontrib>Terzija, V.V.</creatorcontrib><title>A new approach to the arcing faults detection for fast autoreclosure in transmission systems</title><title>IEEE transactions on power delivery</title><addtitle>TPWRD</addtitle><description>To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior influences other voltages and currents distorting them, offered an opportunity to detect the arc by measuring and processing the transmission line terminal voltage and current. A series of simulation studies have shown that the algorithm can be used as an effective tool for arcing faults detection.&lt; &gt;</description><subject>Algorithm design and analysis</subject><subject>Applied sciences</subject><subject>Current measurement</subject><subject>Distortion measurement</subject><subject>Disturbances. Regulation. Protection</subject><subject>Electrical engineering. Electrical power engineering</subject><subject>Electrical fault detection</subject><subject>Electrical power engineering</subject><subject>Exact sciences and technology</subject><subject>Fault detection</subject><subject>Nonlinear distortion</subject><subject>Power networks and lines</subject><subject>Power transmission</subject><subject>Power transmission lines</subject><subject>Transmission line measurements</subject><subject>Voltage</subject><issn>0885-8977</issn><issn>1937-4208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNo9kM1LxDAQxYMouK4evHrKQQQPXZOmbZLjIn7Bghe9CSWdTtxKt10zKbL_vV267Glg5vce8x5j11IspBT2oZCLTCulzQmbSat0kqXCnLKZMCZPjNX6nF0Q_QghMmHFjH0teYd_3G23oXew5rHncY3cBWi6b-7d0EbiNUaE2PQd930YlxS5G2IfENqehoC86XgMrqNNQ7THaEcRN3TJzrxrCa8Oc84-n58-Hl-T1fvL2-NylYBSaUxQaOEVACrv6iot6jzPTFZYWYGUJqtMakylCwtVUXuPCFbnVtaZsjkAyFzN2d3kO4b4HZBiOT4C2Lauw36gMjWZLawwI3g_gRB6ooC-3IZm48KulKLc91cWspz6G9nbg6kjcK0f80FDR0FqrBgVI3YzYQ0iHq8Hj397fHjx</recordid><startdate>19951001</startdate><enddate>19951001</enddate><creator>Djuric, M.B.</creator><creator>Terzija, V.V.</creator><general>IEEE</general><general>Institute of Electrical and Electronics Engineers</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>19951001</creationdate><title>A new approach to the arcing faults detection for fast autoreclosure in transmission systems</title><author>Djuric, M.B. ; Terzija, V.V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Algorithm design and analysis</topic><topic>Applied sciences</topic><topic>Current measurement</topic><topic>Distortion measurement</topic><topic>Disturbances. Regulation. Protection</topic><topic>Electrical engineering. Electrical power engineering</topic><topic>Electrical fault detection</topic><topic>Electrical power engineering</topic><topic>Exact sciences and technology</topic><topic>Fault detection</topic><topic>Nonlinear distortion</topic><topic>Power networks and lines</topic><topic>Power transmission</topic><topic>Power transmission lines</topic><topic>Transmission line measurements</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Djuric, M.B.</creatorcontrib><creatorcontrib>Terzija, V.V.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on power delivery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Djuric, M.B.</au><au>Terzija, V.V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A new approach to the arcing faults detection for fast autoreclosure in transmission systems</atitle><jtitle>IEEE transactions on power delivery</jtitle><stitle>TPWRD</stitle><date>1995-10-01</date><risdate>1995</risdate><volume>10</volume><issue>4</issue><spage>1793</spage><epage>1798</epage><pages>1793-1798</pages><issn>0885-8977</issn><eissn>1937-4208</eissn><coden>ITPDE5</coden><abstract>To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior influences other voltages and currents distorting them, offered an opportunity to detect the arc by measuring and processing the transmission line terminal voltage and current. A series of simulation studies have shown that the algorithm can be used as an effective tool for arcing faults detection.&lt; &gt;</abstract><cop>New York, NY</cop><pub>IEEE</pub><doi>10.1109/61.473378</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0885-8977
ispartof IEEE transactions on power delivery, 1995-10, Vol.10 (4), p.1793-1798
issn 0885-8977
1937-4208
language eng
recordid cdi_proquest_miscellaneous_28496908
source IEEE Electronic Library (IEL) Journals
subjects Algorithm design and analysis
Applied sciences
Current measurement
Distortion measurement
Disturbances. Regulation. Protection
Electrical engineering. Electrical power engineering
Electrical fault detection
Electrical power engineering
Exact sciences and technology
Fault detection
Nonlinear distortion
Power networks and lines
Power transmission
Power transmission lines
Transmission line measurements
Voltage
title A new approach to the arcing faults detection for fast autoreclosure in transmission systems
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T13%3A42%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20new%20approach%20to%20the%20arcing%20faults%20detection%20for%20fast%20autoreclosure%20in%20transmission%20systems&rft.jtitle=IEEE%20transactions%20on%20power%20delivery&rft.au=Djuric,%20M.B.&rft.date=1995-10-01&rft.volume=10&rft.issue=4&rft.spage=1793&rft.epage=1798&rft.pages=1793-1798&rft.issn=0885-8977&rft.eissn=1937-4208&rft.coden=ITPDE5&rft_id=info:doi/10.1109/61.473378&rft_dat=%3Cproquest_ieee_%3E28496908%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=28496908&rft_id=info:pmid/&rft_ieee_id=473378&rfr_iscdi=true