Loading…
A new approach to the arcing faults detection for fast autoreclosure in transmission systems
To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior i...
Saved in:
Published in: | IEEE transactions on power delivery 1995-10, Vol.10 (4), p.1793-1798 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153 |
---|---|
cites | cdi_FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153 |
container_end_page | 1798 |
container_issue | 4 |
container_start_page | 1793 |
container_title | IEEE transactions on power delivery |
container_volume | 10 |
creator | Djuric, M.B. Terzija, V.V. |
description | To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior influences other voltages and currents distorting them, offered an opportunity to detect the arc by measuring and processing the transmission line terminal voltage and current. A series of simulation studies have shown that the algorithm can be used as an effective tool for arcing faults detection.< > |
doi_str_mv | 10.1109/61.473378 |
format | article |
fullrecord | <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_proquest_miscellaneous_28496908</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>473378</ieee_id><sourcerecordid>28496908</sourcerecordid><originalsourceid>FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153</originalsourceid><addsrcrecordid>eNo9kM1LxDAQxYMouK4evHrKQQQPXZOmbZLjIn7Bghe9CSWdTtxKt10zKbL_vV267Glg5vce8x5j11IspBT2oZCLTCulzQmbSat0kqXCnLKZMCZPjNX6nF0Q_QghMmHFjH0teYd_3G23oXew5rHncY3cBWi6b-7d0EbiNUaE2PQd930YlxS5G2IfENqehoC86XgMrqNNQ7THaEcRN3TJzrxrCa8Oc84-n58-Hl-T1fvL2-NylYBSaUxQaOEVACrv6iot6jzPTFZYWYGUJqtMakylCwtVUXuPCFbnVtaZsjkAyFzN2d3kO4b4HZBiOT4C2Lauw36gMjWZLawwI3g_gRB6ooC-3IZm48KulKLc91cWspz6G9nbg6kjcK0f80FDR0FqrBgVI3YzYQ0iHq8Hj397fHjx</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28496908</pqid></control><display><type>article</type><title>A new approach to the arcing faults detection for fast autoreclosure in transmission systems</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Djuric, M.B. ; Terzija, V.V.</creator><creatorcontrib>Djuric, M.B. ; Terzija, V.V.</creatorcontrib><description>To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior influences other voltages and currents distorting them, offered an opportunity to detect the arc by measuring and processing the transmission line terminal voltage and current. A series of simulation studies have shown that the algorithm can be used as an effective tool for arcing faults detection.< ></description><identifier>ISSN: 0885-8977</identifier><identifier>EISSN: 1937-4208</identifier><identifier>DOI: 10.1109/61.473378</identifier><identifier>CODEN: ITPDE5</identifier><language>eng</language><publisher>New York, NY: IEEE</publisher><subject>Algorithm design and analysis ; Applied sciences ; Current measurement ; Distortion measurement ; Disturbances. Regulation. Protection ; Electrical engineering. Electrical power engineering ; Electrical fault detection ; Electrical power engineering ; Exact sciences and technology ; Fault detection ; Nonlinear distortion ; Power networks and lines ; Power transmission ; Power transmission lines ; Transmission line measurements ; Voltage</subject><ispartof>IEEE transactions on power delivery, 1995-10, Vol.10 (4), p.1793-1798</ispartof><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153</citedby><cites>FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/473378$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925,54796</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=2890110$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Djuric, M.B.</creatorcontrib><creatorcontrib>Terzija, V.V.</creatorcontrib><title>A new approach to the arcing faults detection for fast autoreclosure in transmission systems</title><title>IEEE transactions on power delivery</title><addtitle>TPWRD</addtitle><description>To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior influences other voltages and currents distorting them, offered an opportunity to detect the arc by measuring and processing the transmission line terminal voltage and current. A series of simulation studies have shown that the algorithm can be used as an effective tool for arcing faults detection.< ></description><subject>Algorithm design and analysis</subject><subject>Applied sciences</subject><subject>Current measurement</subject><subject>Distortion measurement</subject><subject>Disturbances. Regulation. Protection</subject><subject>Electrical engineering. Electrical power engineering</subject><subject>Electrical fault detection</subject><subject>Electrical power engineering</subject><subject>Exact sciences and technology</subject><subject>Fault detection</subject><subject>Nonlinear distortion</subject><subject>Power networks and lines</subject><subject>Power transmission</subject><subject>Power transmission lines</subject><subject>Transmission line measurements</subject><subject>Voltage</subject><issn>0885-8977</issn><issn>1937-4208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNo9kM1LxDAQxYMouK4evHrKQQQPXZOmbZLjIn7Bghe9CSWdTtxKt10zKbL_vV267Glg5vce8x5j11IspBT2oZCLTCulzQmbSat0kqXCnLKZMCZPjNX6nF0Q_QghMmHFjH0teYd_3G23oXew5rHncY3cBWi6b-7d0EbiNUaE2PQd930YlxS5G2IfENqehoC86XgMrqNNQ7THaEcRN3TJzrxrCa8Oc84-n58-Hl-T1fvL2-NylYBSaUxQaOEVACrv6iot6jzPTFZYWYGUJqtMakylCwtVUXuPCFbnVtaZsjkAyFzN2d3kO4b4HZBiOT4C2Lauw36gMjWZLawwI3g_gRB6ooC-3IZm48KulKLc91cWspz6G9nbg6kjcK0f80FDR0FqrBgVI3YzYQ0iHq8Hj397fHjx</recordid><startdate>19951001</startdate><enddate>19951001</enddate><creator>Djuric, M.B.</creator><creator>Terzija, V.V.</creator><general>IEEE</general><general>Institute of Electrical and Electronics Engineers</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>19951001</creationdate><title>A new approach to the arcing faults detection for fast autoreclosure in transmission systems</title><author>Djuric, M.B. ; Terzija, V.V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Algorithm design and analysis</topic><topic>Applied sciences</topic><topic>Current measurement</topic><topic>Distortion measurement</topic><topic>Disturbances. Regulation. Protection</topic><topic>Electrical engineering. Electrical power engineering</topic><topic>Electrical fault detection</topic><topic>Electrical power engineering</topic><topic>Exact sciences and technology</topic><topic>Fault detection</topic><topic>Nonlinear distortion</topic><topic>Power networks and lines</topic><topic>Power transmission</topic><topic>Power transmission lines</topic><topic>Transmission line measurements</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Djuric, M.B.</creatorcontrib><creatorcontrib>Terzija, V.V.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on power delivery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Djuric, M.B.</au><au>Terzija, V.V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A new approach to the arcing faults detection for fast autoreclosure in transmission systems</atitle><jtitle>IEEE transactions on power delivery</jtitle><stitle>TPWRD</stitle><date>1995-10-01</date><risdate>1995</risdate><volume>10</volume><issue>4</issue><spage>1793</spage><epage>1798</epage><pages>1793-1798</pages><issn>0885-8977</issn><eissn>1937-4208</eissn><coden>ITPDE5</coden><abstract>To avoid automatic reclosing on permanent faults, a new numerical algorithm for power transmission network arcing faults detection has been developed. Some important features of a long arc in air are investigated and used as a basis in the algorithm design. The fact that the nonlinear arc behavior influences other voltages and currents distorting them, offered an opportunity to detect the arc by measuring and processing the transmission line terminal voltage and current. A series of simulation studies have shown that the algorithm can be used as an effective tool for arcing faults detection.< ></abstract><cop>New York, NY</cop><pub>IEEE</pub><doi>10.1109/61.473378</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0885-8977 |
ispartof | IEEE transactions on power delivery, 1995-10, Vol.10 (4), p.1793-1798 |
issn | 0885-8977 1937-4208 |
language | eng |
recordid | cdi_proquest_miscellaneous_28496908 |
source | IEEE Electronic Library (IEL) Journals |
subjects | Algorithm design and analysis Applied sciences Current measurement Distortion measurement Disturbances. Regulation. Protection Electrical engineering. Electrical power engineering Electrical fault detection Electrical power engineering Exact sciences and technology Fault detection Nonlinear distortion Power networks and lines Power transmission Power transmission lines Transmission line measurements Voltage |
title | A new approach to the arcing faults detection for fast autoreclosure in transmission systems |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T13%3A42%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20new%20approach%20to%20the%20arcing%20faults%20detection%20for%20fast%20autoreclosure%20in%20transmission%20systems&rft.jtitle=IEEE%20transactions%20on%20power%20delivery&rft.au=Djuric,%20M.B.&rft.date=1995-10-01&rft.volume=10&rft.issue=4&rft.spage=1793&rft.epage=1798&rft.pages=1793-1798&rft.issn=0885-8977&rft.eissn=1937-4208&rft.coden=ITPDE5&rft_id=info:doi/10.1109/61.473378&rft_dat=%3Cproquest_ieee_%3E28496908%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c332t-e070f3cce3fadb26d55484691bc1184b8288b769cb6dffeec97591d4395ccc153%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=28496908&rft_id=info:pmid/&rft_ieee_id=473378&rfr_iscdi=true |