Loading…

Incidence, causes, and management of failed awake fibreoptic intubation—A retrospective study of 833 procedures

Awake fibreoptic intubation has been considered a gold standard in the management of the difficult airway. However, failure may cause critical situations. The aim of this study was to investigate the incidence and causes of failed awake fibreoptic intubation at a tertiary care hospital. The study wa...

Full description

Saved in:
Bibliographic Details
Published in:Acta anaesthesiologica Scandinavica 2023-11, Vol.67 (10), p.1341-1347
Main Authors: Karlsen, Kjetil Andreas Hognestad, Gisvold, Sven Erik, Nordseth, Trond, Fasting, Sigurd
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Awake fibreoptic intubation has been considered a gold standard in the management of the difficult airway. However, failure may cause critical situations. The aim of this study was to investigate the incidence and causes of failed awake fibreoptic intubation at a tertiary care hospital. The study was conducted at St. Olav University Hospital in Trondheim, Norway. Problems occurring during anaesthesia are routinely recorded in the electronic anaesthesia information system (Picis Clinical Solutions Inc.), including difficult intubations. We applied text search on all anaesthesia records between 2011 and 2021 and identified 833 awake fibreoptic intubations. The anaesthesia records were examined to identify failed awake fibreoptic intubations, the cause of failure and how the airway ultimately was secured. Among 233,938 patients who received anaesthesia, 90,397 received tracheal intubation and 833 received awake fibreoptic intubation. Twenty‐nine of the procedures failed. In nine patients the failure caused loss of airway control with desaturation and hypoventilation. The major causes of failure were dislodged tube after induction of general anaesthesia ( n  = 8), patient distress ( n  = 5), tube not able to pass ( n  = 5), and airway bleeding ( n  = 3). The situations were primarily solved using direct laryngoscopy, with or without bougie, or with video laryngoscopy. Tracheostomy was performed in four patients. Awake fibreoptic intubation failed in 3.5% of patients, most often due to dislocation, problems passing the tracheal tube, or patient discomfort. The failure rate was higher than in previous studies.
ISSN:0001-5172
1399-6576
DOI:10.1111/aas.14313