p-beam monitoring system for CP LEAR

A monitoring system has been developed for the antiproton beam used in experiments on the CP violating decays of K/sup 0/ and anti-K/sup 0/ by the CP LEAR collaboration at LEAR, CERN. The beam position is measured by means of two small MWPCs. In each MWPC two anode wires, 8 mm apart, provide gas amp...

Full description

Saved in:
Bibliographic Details
Published in:IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) 1990-04, Vol.37 (2), p.53-55
Main Authors: van den Putte, M., van Eijk, C.W.E., Hollander, R.W., Johner, H.U., Santoni, C.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A monitoring system has been developed for the antiproton beam used in experiments on the CP violating decays of K/sup 0/ and anti-K/sup 0/ by the CP LEAR collaboration at LEAR, CERN. The beam position is measured by means of two small MWPCs. In each MWPC two anode wires, 8 mm apart, provide gas amplification. The position of the beam is obtained from induced current signals on cathode strips. A small scintillator (diameter 7 mm, thickness 1 mm) gives a signal to be included in the trigger. The scintillation light is guided to a PM outside the solenoid by means of 5-m-long PMMA (plexiglass) fibers. The system is mounted on the beam pipe, close to the center of the experimental setup. The beam position resolution is better than 0.5 mm, and the time resolution is approximately=100 ps.< >
ISSN:0018-9499
1558-1578
DOI:10.1109/23.106591