RF-DC differences of coaxial thermal standards
The RF-DC differences ( delta ) of thermal converters are calculated from complex transmission line theory. The Boella effect and the skin effect are considered. The formula delta =Af/sup 1/2/+Bf/sup 2/ can be obtained by experiments and proved by comparison of converters. The uncertainty of delta i...
Saved in:
Published in: | IEEE transactions on instrumentation and measurement 1990-04, Vol.39 (2), p.313-317 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The RF-DC differences ( delta ) of thermal converters are calculated from complex transmission line theory. The Boella effect and the skin effect are considered. The formula delta =Af/sup 1/2/+Bf/sup 2/ can be obtained by experiments and proved by comparison of converters. The uncertainty of delta is 0.01% at 1 MHz and 0.1% at 30 MHz.< > |
---|---|