Loading…

Simulation studies for cylindrical positron tomography

A VMEbus-based microcomputer system has been used to implement a model for simulation of the flux of gamma rays to cylindrical PET (positron-emission-tomography) detector systems. The model is capable of tracing over one million photons per hour, and has been used to explore some of the effects of &...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on nuclear science 1988-02, Vol.35 (1), p.708-711
Main Authors: Stearns, C.W., Burnham, C.A., Chesler, D.A., Brownell, G.L.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c342t-da9a8580e9f9316b50ef28434904c0e0244f705df3a7e82f2f07d22ee48e66b83
cites cdi_FETCH-LOGICAL-c342t-da9a8580e9f9316b50ef28434904c0e0244f705df3a7e82f2f07d22ee48e66b83
container_end_page 711
container_issue 1
container_start_page 708
container_title IEEE transactions on nuclear science
container_volume 35
creator Stearns, C.W.
Burnham, C.A.
Chesler, D.A.
Brownell, G.L.
description A VMEbus-based microcomputer system has been used to implement a model for simulation of the flux of gamma rays to cylindrical PET (positron-emission-tomography) detector systems. The model is capable of tracing over one million photons per hour, and has been used to explore some of the effects of 'opening up' planar detector geometries into volumetric imagers. Gross single-channel and coincidence rates can be estimated using the model, as well as the distribution patterns of both true and scattered coincidence events in the radial and axial directions. The model demonstrates the increases in scattered coincidences that are encountered in true (i.e. no collimation) three-dimensional PET imaging and underscores the importance of detector energy resolution in managing scattered events. The projection plane view of scattered coincidence events suggests that scatter compensation can be attempted by filtering the projection data by two-dimensional techniques. Combining this model with models of detector properties and reconstruction processes will permit a full simulation of the entire PET imaging session.< >
doi_str_mv 10.1109/23.12816
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_28582414</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>12816</ieee_id><sourcerecordid>28582414</sourcerecordid><originalsourceid>FETCH-LOGICAL-c342t-da9a8580e9f9316b50ef28434904c0e0244f705df3a7e82f2f07d22ee48e66b83</originalsourceid><addsrcrecordid>eNpF0EtLxDAUBeAgCtZRcOuuK3HT8ebVJksZfMGAC3UdMu2NRtqmJu1i_r11Kri6HO7HWRxCLimsKQV9y_iaMkXLI5JRKVVBZaWOSQZAVaGF1qfkLKWvOQoJMiPlq--m1o4-9Hkap8Zjyl2Ieb1vfd9EX9s2H0LyY5zBGLrwEe3wuT8nJ862CS_-7oq8P9y_bZ6K7cvj8-ZuW9RcsLForLZKKkDtNKflTgI6pgQXGkQNCEwIV4FsHLcVKuaYg6phDFEoLMud4ityvfQOMXxPmEbT-VRj29oew5QMm9uZoGKGNwusY0gpojND9J2Ne0PB_A5jGDeHYWZ6tVCPiP_s8PsBLIxdIw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28582414</pqid></control><display><type>article</type><title>Simulation studies for cylindrical positron tomography</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Stearns, C.W. ; Burnham, C.A. ; Chesler, D.A. ; Brownell, G.L.</creator><creatorcontrib>Stearns, C.W. ; Burnham, C.A. ; Chesler, D.A. ; Brownell, G.L.</creatorcontrib><description>A VMEbus-based microcomputer system has been used to implement a model for simulation of the flux of gamma rays to cylindrical PET (positron-emission-tomography) detector systems. The model is capable of tracing over one million photons per hour, and has been used to explore some of the effects of 'opening up' planar detector geometries into volumetric imagers. Gross single-channel and coincidence rates can be estimated using the model, as well as the distribution patterns of both true and scattered coincidence events in the radial and axial directions. The model demonstrates the increases in scattered coincidences that are encountered in true (i.e. no collimation) three-dimensional PET imaging and underscores the importance of detector energy resolution in managing scattered events. The projection plane view of scattered coincidence events suggests that scatter compensation can be attempted by filtering the projection data by two-dimensional techniques. Combining this model with models of detector properties and reconstruction processes will permit a full simulation of the entire PET imaging session.&lt; &gt;</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/23.12816</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>IEEE</publisher><subject>Collimators ; Electromagnetic scattering ; Gamma ray detection ; Gamma ray detectors ; Gamma rays ; Geometry ; Microcomputers ; Particle scattering ; Positron emission tomography ; Solid modeling</subject><ispartof>IEEE transactions on nuclear science, 1988-02, Vol.35 (1), p.708-711</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c342t-da9a8580e9f9316b50ef28434904c0e0244f705df3a7e82f2f07d22ee48e66b83</citedby><cites>FETCH-LOGICAL-c342t-da9a8580e9f9316b50ef28434904c0e0244f705df3a7e82f2f07d22ee48e66b83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/12816$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27922,27923,54794</link.rule.ids></links><search><creatorcontrib>Stearns, C.W.</creatorcontrib><creatorcontrib>Burnham, C.A.</creatorcontrib><creatorcontrib>Chesler, D.A.</creatorcontrib><creatorcontrib>Brownell, G.L.</creatorcontrib><title>Simulation studies for cylindrical positron tomography</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>A VMEbus-based microcomputer system has been used to implement a model for simulation of the flux of gamma rays to cylindrical PET (positron-emission-tomography) detector systems. The model is capable of tracing over one million photons per hour, and has been used to explore some of the effects of 'opening up' planar detector geometries into volumetric imagers. Gross single-channel and coincidence rates can be estimated using the model, as well as the distribution patterns of both true and scattered coincidence events in the radial and axial directions. The model demonstrates the increases in scattered coincidences that are encountered in true (i.e. no collimation) three-dimensional PET imaging and underscores the importance of detector energy resolution in managing scattered events. The projection plane view of scattered coincidence events suggests that scatter compensation can be attempted by filtering the projection data by two-dimensional techniques. Combining this model with models of detector properties and reconstruction processes will permit a full simulation of the entire PET imaging session.&lt; &gt;</description><subject>Collimators</subject><subject>Electromagnetic scattering</subject><subject>Gamma ray detection</subject><subject>Gamma ray detectors</subject><subject>Gamma rays</subject><subject>Geometry</subject><subject>Microcomputers</subject><subject>Particle scattering</subject><subject>Positron emission tomography</subject><subject>Solid modeling</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1988</creationdate><recordtype>article</recordtype><recordid>eNpF0EtLxDAUBeAgCtZRcOuuK3HT8ebVJksZfMGAC3UdMu2NRtqmJu1i_r11Kri6HO7HWRxCLimsKQV9y_iaMkXLI5JRKVVBZaWOSQZAVaGF1qfkLKWvOQoJMiPlq--m1o4-9Hkap8Zjyl2Ieb1vfd9EX9s2H0LyY5zBGLrwEe3wuT8nJ862CS_-7oq8P9y_bZ6K7cvj8-ZuW9RcsLForLZKKkDtNKflTgI6pgQXGkQNCEwIV4FsHLcVKuaYg6phDFEoLMud4ityvfQOMXxPmEbT-VRj29oew5QMm9uZoGKGNwusY0gpojND9J2Ne0PB_A5jGDeHYWZ6tVCPiP_s8PsBLIxdIw</recordid><startdate>19880201</startdate><enddate>19880201</enddate><creator>Stearns, C.W.</creator><creator>Burnham, C.A.</creator><creator>Chesler, D.A.</creator><creator>Brownell, G.L.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>19880201</creationdate><title>Simulation studies for cylindrical positron tomography</title><author>Stearns, C.W. ; Burnham, C.A. ; Chesler, D.A. ; Brownell, G.L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c342t-da9a8580e9f9316b50ef28434904c0e0244f705df3a7e82f2f07d22ee48e66b83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1988</creationdate><topic>Collimators</topic><topic>Electromagnetic scattering</topic><topic>Gamma ray detection</topic><topic>Gamma ray detectors</topic><topic>Gamma rays</topic><topic>Geometry</topic><topic>Microcomputers</topic><topic>Particle scattering</topic><topic>Positron emission tomography</topic><topic>Solid modeling</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stearns, C.W.</creatorcontrib><creatorcontrib>Burnham, C.A.</creatorcontrib><creatorcontrib>Chesler, D.A.</creatorcontrib><creatorcontrib>Brownell, G.L.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stearns, C.W.</au><au>Burnham, C.A.</au><au>Chesler, D.A.</au><au>Brownell, G.L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simulation studies for cylindrical positron tomography</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>1988-02-01</date><risdate>1988</risdate><volume>35</volume><issue>1</issue><spage>708</spage><epage>711</epage><pages>708-711</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>A VMEbus-based microcomputer system has been used to implement a model for simulation of the flux of gamma rays to cylindrical PET (positron-emission-tomography) detector systems. The model is capable of tracing over one million photons per hour, and has been used to explore some of the effects of 'opening up' planar detector geometries into volumetric imagers. Gross single-channel and coincidence rates can be estimated using the model, as well as the distribution patterns of both true and scattered coincidence events in the radial and axial directions. The model demonstrates the increases in scattered coincidences that are encountered in true (i.e. no collimation) three-dimensional PET imaging and underscores the importance of detector energy resolution in managing scattered events. The projection plane view of scattered coincidence events suggests that scatter compensation can be attempted by filtering the projection data by two-dimensional techniques. Combining this model with models of detector properties and reconstruction processes will permit a full simulation of the entire PET imaging session.&lt; &gt;</abstract><pub>IEEE</pub><doi>10.1109/23.12816</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0018-9499
ispartof IEEE transactions on nuclear science, 1988-02, Vol.35 (1), p.708-711
issn 0018-9499
1558-1578
language eng
recordid cdi_proquest_miscellaneous_28582414
source IEEE Electronic Library (IEL) Journals
subjects Collimators
Electromagnetic scattering
Gamma ray detection
Gamma ray detectors
Gamma rays
Geometry
Microcomputers
Particle scattering
Positron emission tomography
Solid modeling
title Simulation studies for cylindrical positron tomography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T12%3A44%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simulation%20studies%20for%20cylindrical%20positron%20tomography&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Stearns,%20C.W.&rft.date=1988-02-01&rft.volume=35&rft.issue=1&rft.spage=708&rft.epage=711&rft.pages=708-711&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/23.12816&rft_dat=%3Cproquest_cross%3E28582414%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c342t-da9a8580e9f9316b50ef28434904c0e0244f705df3a7e82f2f07d22ee48e66b83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=28582414&rft_id=info:pmid/&rft_ieee_id=12816&rfr_iscdi=true