Stresses, strains and cracks in a helium-implanted SiC/C composite
Helium was implanted at room temperature and at 1000 °C into 3 × 3 mm 2 bars of a SiC/C particulate composite, uniformly to depths of 117 and 254 μm, respectively. Profilometry showed strong bending of the bars due to volume expansion in the implanted layer, which is ascribed to concurrently produce...
Saved in:
Published in: | Journal of nuclear materials 2005-02, Vol.336 (2), p.194-200 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Helium was implanted at room temperature and at 1000
°C into 3
×
3
mm
2 bars of a SiC/C particulate composite, uniformly to depths of 117 and 254
μm, respectively. Profilometry showed strong bending of the bars due to volume expansion in the implanted layer, which is ascribed to concurrently produced displacement defects. For uniform helium concentrations above ≈350
appm in layers of 254
μm thickness, scanning electron microscopy revealed spontaneous cracking just below the implanted region where tensile stress was maximum, while this critical concentration was above ≈700
appm for the 117
μm implanted layer. Below these critical concentrations the influence of helium on strength of the material was studied by 3-point bending tests. In a detailed analysis of the dependence of cracking on specimen geometry and applied stress, internal stresses from volume expansion were included. This analysis indicated hardening by implantation, in contrast to the apparent reduction of strength. The dose and temperature dependence of volume expansion was fitted by a defect recovery model. |
---|---|
ISSN: | 0022-3115 1873-4820 |
DOI: | 10.1016/j.jnucmat.2004.09.014 |