Robust mixed electron‐photon radiation therapy planning for soft tissue sarcoma

BACKGROUNDMixed electron-photon beam radiation therapy (MBRT) is an emerging technique in which external electron and photon beams are simultaneously optimized into a single treatment plan. MBRT exploits the steep dose falloff and high surface dose of electrons while maintaining target conformity by...

Full description

Saved in:
Bibliographic Details
Published in:Medical physics (Lancaster) 2023-10, Vol.50 (10), p.6502-6513
Main Authors: Heng, Veng Jean, Serban, Monica, Renaud, Marc‐André, Freeman, Carolyn, Seuntjens, Jan
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:BACKGROUNDMixed electron-photon beam radiation therapy (MBRT) is an emerging technique in which external electron and photon beams are simultaneously optimized into a single treatment plan. MBRT exploits the steep dose falloff and high surface dose of electrons while maintaining target conformity by leveraging the sharp penumbra of photons. PURPOSEThis study investigates the dosimetric benefits of MBRT for soft tissue sarcoma (STS) patients. MATERIAL AND METHODSA retrospective cohort of 22 STS of the lower extremity treated with conventional photon-based Volumetric Modulated Arc Therapy (VMAT) were replanned with MBRT. Both VMAT and MBRT treatments were planned on the Varian TrueBeam linac using the Millenium multi-leaf collimator. No electron applicator, cutout or additional collimating devices were used for electron beams of MBRT plans. MBRT plans were optimized to use a combination of 6 MV photons and five electron energies (6, 9, 12, 16, 20 MeV) by a robust column generation algorithm. Electron beams in this study were planned at standard 100 cm source-axis distance (SAD). The dose to the clinical target volume (CTV), bone, normal tissue strip and other organs-at-risk (OARs) were compared using a Wilcoxon signed-rank test. RESULTSAs part of the original VMAT treatment, tissue-equivalent bolus was required in 10 of the 22 patients. MBRT plans did not require bolus by virtue of the higher electron entrance dose. CTV coverage by the prescription dose was found to be clinically equivalent between plans of either modality: V 50Gy $V_{\text{50Gy}}$ (MBRT) = 97.9 ± 0.2% versus V 50Gy $V_{\text{50Gy}}$ (VMAT) = 98.1 ± 0.6% (p=0.34). Evaluating the absolute paired difference between doses to OARs in MBRT and VMAT plans, we observed lower V 20Gy $V_{\text{20Gy}}$ to normal tissue in MBRT plans by 14.9 ± 3.2% ( p < 10 - 6 $p
ISSN:0094-2405
2473-4209
DOI:10.1002/mp.16709