Loading…

Determination of phosphorescence lifetimes in the presence of high background signals using phase-shift measurements

Phosphorescence-based optical sensors are typically based on intensity or triplet-lifetime measurements. Lifetime determinations may be performed in the frequency-domain by exciting the luminophor with a sinusoidal modulated light source and measuring the phase shift between the excitation light and...

Full description

Saved in:
Bibliographic Details
Published in:Sensors and actuators. B, Chemical Chemical, 2006-01, Vol.113 (1), p.249-258
Main Authors: Valledor, Marta, Campo, Juan Carlos, Sánchez-Barragán, Israel, Costa-Fernández, José M., Alvarez, Juan Carlos, Sanz-Medel, Alfredo
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c361t-ededf50734d473bd96b89b8bd79fcf63b52d28c34f0bf7b9442224d6441be5d93
cites cdi_FETCH-LOGICAL-c361t-ededf50734d473bd96b89b8bd79fcf63b52d28c34f0bf7b9442224d6441be5d93
container_end_page 258
container_issue 1
container_start_page 249
container_title Sensors and actuators. B, Chemical
container_volume 113
creator Valledor, Marta
Campo, Juan Carlos
Sánchez-Barragán, Israel
Costa-Fernández, José M.
Alvarez, Juan Carlos
Sanz-Medel, Alfredo
description Phosphorescence-based optical sensors are typically based on intensity or triplet-lifetime measurements. Lifetime determinations may be performed in the frequency-domain by exciting the luminophor with a sinusoidal modulated light source and measuring the phase shift between the excitation light and the phosphorescence emission. Modulated scattered light at the same frequency of the modulating signal must be removed in order to perform accurate measurements. A new and simple method based on phase-modulation measurements is presented to measure the triplet-lifetime of a long-lifetime phosphorescent luminophor, even if high levels of background short-lived fluorescence or scattered light are present. The method is based on the measurement of the phase shift between excitation and emission light at two different frequencies and it turned to provide reliable lifetime measurements if the background light lifetime is significantly shorter than that of the phosphorescent emission to be measured. Theoretical aspects of the proposed methodology, the design and construction of a fiber-optical measuring system and the selection of the optimal frequencies to perform the accurate lifetime measurements are discussed. Finally, the performance of the proposed measurement method has been assessed in the determination of the triplet-lifetime values of the metal chelate Al-ferron immobilized in an inorganic sol–gel support (an oxygen indicator which displays a strong fluorescence emission overlapping significantly with the measured phosphorescence emission).
doi_str_mv 10.1016/j.snb.2005.02.054
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_28644431</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S092540050500239X</els_id><sourcerecordid>28644431</sourcerecordid><originalsourceid>FETCH-LOGICAL-c361t-ededf50734d473bd96b89b8bd79fcf63b52d28c34f0bf7b9442224d6441be5d93</originalsourceid><addsrcrecordid>eNp9kTtv3DAQhInABnJ-_IB0rAw3kvnSC64Mx0kMHJAmrgmRXJ54OVEXLhUg_z68XGoXiy3mmwF2h5BPnNWc8fZhX2M0tWCsqZmoWaM-kA3vO1lJ1nUXZMMG0VSqyB_JFeKeMaZkyzYkf4YMaQ5xzGGJdPH0OC1YJgFaiBboIXjIYQakIdI8AT0W6Z9S4CnsJmpG-3OXljU6imEXxwPSFUPclagRocIp-ExnGHFNMEPMeEMufaHg9v--Jm9fXn48f6u237--Pj9tKytbnitw4HzDOqmc6qRxQ2v6wfTGdYO3vpWmEU70VirPjO_MoJQQQrlWKW6gcYO8Jnfn3GNafq2AWc-hXHU4jBGWFbXoC6skL-D9uyBnveCD6AZRUH5GbVoQE3h9TGEe058C6VMVeq9LFfpUhWZClyqK5_HsgXLs7wBJow2nF7qQwGbtlvCO-y8R2ZQz</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1082192792</pqid></control><display><type>article</type><title>Determination of phosphorescence lifetimes in the presence of high background signals using phase-shift measurements</title><source>ScienceDirect Freedom Collection</source><creator>Valledor, Marta ; Campo, Juan Carlos ; Sánchez-Barragán, Israel ; Costa-Fernández, José M. ; Alvarez, Juan Carlos ; Sanz-Medel, Alfredo</creator><creatorcontrib>Valledor, Marta ; Campo, Juan Carlos ; Sánchez-Barragán, Israel ; Costa-Fernández, José M. ; Alvarez, Juan Carlos ; Sanz-Medel, Alfredo</creatorcontrib><description>Phosphorescence-based optical sensors are typically based on intensity or triplet-lifetime measurements. Lifetime determinations may be performed in the frequency-domain by exciting the luminophor with a sinusoidal modulated light source and measuring the phase shift between the excitation light and the phosphorescence emission. Modulated scattered light at the same frequency of the modulating signal must be removed in order to perform accurate measurements. A new and simple method based on phase-modulation measurements is presented to measure the triplet-lifetime of a long-lifetime phosphorescent luminophor, even if high levels of background short-lived fluorescence or scattered light are present. The method is based on the measurement of the phase shift between excitation and emission light at two different frequencies and it turned to provide reliable lifetime measurements if the background light lifetime is significantly shorter than that of the phosphorescent emission to be measured. Theoretical aspects of the proposed methodology, the design and construction of a fiber-optical measuring system and the selection of the optimal frequencies to perform the accurate lifetime measurements are discussed. Finally, the performance of the proposed measurement method has been assessed in the determination of the triplet-lifetime values of the metal chelate Al-ferron immobilized in an inorganic sol–gel support (an oxygen indicator which displays a strong fluorescence emission overlapping significantly with the measured phosphorescence emission).</description><identifier>ISSN: 0925-4005</identifier><identifier>EISSN: 1873-3077</identifier><identifier>DOI: 10.1016/j.snb.2005.02.054</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Emission ; Emission analysis ; Excitation ; Fiber optics ; Fluorescence ; Frequency-domain ; Optical fibers ; Phase shift ; Phosphorescence ; Quenching</subject><ispartof>Sensors and actuators. B, Chemical, 2006-01, Vol.113 (1), p.249-258</ispartof><rights>2005 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c361t-ededf50734d473bd96b89b8bd79fcf63b52d28c34f0bf7b9442224d6441be5d93</citedby><cites>FETCH-LOGICAL-c361t-ededf50734d473bd96b89b8bd79fcf63b52d28c34f0bf7b9442224d6441be5d93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Valledor, Marta</creatorcontrib><creatorcontrib>Campo, Juan Carlos</creatorcontrib><creatorcontrib>Sánchez-Barragán, Israel</creatorcontrib><creatorcontrib>Costa-Fernández, José M.</creatorcontrib><creatorcontrib>Alvarez, Juan Carlos</creatorcontrib><creatorcontrib>Sanz-Medel, Alfredo</creatorcontrib><title>Determination of phosphorescence lifetimes in the presence of high background signals using phase-shift measurements</title><title>Sensors and actuators. B, Chemical</title><description>Phosphorescence-based optical sensors are typically based on intensity or triplet-lifetime measurements. Lifetime determinations may be performed in the frequency-domain by exciting the luminophor with a sinusoidal modulated light source and measuring the phase shift between the excitation light and the phosphorescence emission. Modulated scattered light at the same frequency of the modulating signal must be removed in order to perform accurate measurements. A new and simple method based on phase-modulation measurements is presented to measure the triplet-lifetime of a long-lifetime phosphorescent luminophor, even if high levels of background short-lived fluorescence or scattered light are present. The method is based on the measurement of the phase shift between excitation and emission light at two different frequencies and it turned to provide reliable lifetime measurements if the background light lifetime is significantly shorter than that of the phosphorescent emission to be measured. Theoretical aspects of the proposed methodology, the design and construction of a fiber-optical measuring system and the selection of the optimal frequencies to perform the accurate lifetime measurements are discussed. Finally, the performance of the proposed measurement method has been assessed in the determination of the triplet-lifetime values of the metal chelate Al-ferron immobilized in an inorganic sol–gel support (an oxygen indicator which displays a strong fluorescence emission overlapping significantly with the measured phosphorescence emission).</description><subject>Emission</subject><subject>Emission analysis</subject><subject>Excitation</subject><subject>Fiber optics</subject><subject>Fluorescence</subject><subject>Frequency-domain</subject><subject>Optical fibers</subject><subject>Phase shift</subject><subject>Phosphorescence</subject><subject>Quenching</subject><issn>0925-4005</issn><issn>1873-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp9kTtv3DAQhInABnJ-_IB0rAw3kvnSC64Mx0kMHJAmrgmRXJ54OVEXLhUg_z68XGoXiy3mmwF2h5BPnNWc8fZhX2M0tWCsqZmoWaM-kA3vO1lJ1nUXZMMG0VSqyB_JFeKeMaZkyzYkf4YMaQ5xzGGJdPH0OC1YJgFaiBboIXjIYQakIdI8AT0W6Z9S4CnsJmpG-3OXljU6imEXxwPSFUPclagRocIp-ExnGHFNMEPMeEMufaHg9v--Jm9fXn48f6u237--Pj9tKytbnitw4HzDOqmc6qRxQ2v6wfTGdYO3vpWmEU70VirPjO_MoJQQQrlWKW6gcYO8Jnfn3GNafq2AWc-hXHU4jBGWFbXoC6skL-D9uyBnveCD6AZRUH5GbVoQE3h9TGEe058C6VMVeq9LFfpUhWZClyqK5_HsgXLs7wBJow2nF7qQwGbtlvCO-y8R2ZQz</recordid><startdate>20060117</startdate><enddate>20060117</enddate><creator>Valledor, Marta</creator><creator>Campo, Juan Carlos</creator><creator>Sánchez-Barragán, Israel</creator><creator>Costa-Fernández, José M.</creator><creator>Alvarez, Juan Carlos</creator><creator>Sanz-Medel, Alfredo</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><scope>7SP</scope><scope>F28</scope></search><sort><creationdate>20060117</creationdate><title>Determination of phosphorescence lifetimes in the presence of high background signals using phase-shift measurements</title><author>Valledor, Marta ; Campo, Juan Carlos ; Sánchez-Barragán, Israel ; Costa-Fernández, José M. ; Alvarez, Juan Carlos ; Sanz-Medel, Alfredo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c361t-ededf50734d473bd96b89b8bd79fcf63b52d28c34f0bf7b9442224d6441be5d93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Emission</topic><topic>Emission analysis</topic><topic>Excitation</topic><topic>Fiber optics</topic><topic>Fluorescence</topic><topic>Frequency-domain</topic><topic>Optical fibers</topic><topic>Phase shift</topic><topic>Phosphorescence</topic><topic>Quenching</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Valledor, Marta</creatorcontrib><creatorcontrib>Campo, Juan Carlos</creatorcontrib><creatorcontrib>Sánchez-Barragán, Israel</creatorcontrib><creatorcontrib>Costa-Fernández, José M.</creatorcontrib><creatorcontrib>Alvarez, Juan Carlos</creatorcontrib><creatorcontrib>Sanz-Medel, Alfredo</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Valledor, Marta</au><au>Campo, Juan Carlos</au><au>Sánchez-Barragán, Israel</au><au>Costa-Fernández, José M.</au><au>Alvarez, Juan Carlos</au><au>Sanz-Medel, Alfredo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of phosphorescence lifetimes in the presence of high background signals using phase-shift measurements</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2006-01-17</date><risdate>2006</risdate><volume>113</volume><issue>1</issue><spage>249</spage><epage>258</epage><pages>249-258</pages><issn>0925-4005</issn><eissn>1873-3077</eissn><abstract>Phosphorescence-based optical sensors are typically based on intensity or triplet-lifetime measurements. Lifetime determinations may be performed in the frequency-domain by exciting the luminophor with a sinusoidal modulated light source and measuring the phase shift between the excitation light and the phosphorescence emission. Modulated scattered light at the same frequency of the modulating signal must be removed in order to perform accurate measurements. A new and simple method based on phase-modulation measurements is presented to measure the triplet-lifetime of a long-lifetime phosphorescent luminophor, even if high levels of background short-lived fluorescence or scattered light are present. The method is based on the measurement of the phase shift between excitation and emission light at two different frequencies and it turned to provide reliable lifetime measurements if the background light lifetime is significantly shorter than that of the phosphorescent emission to be measured. Theoretical aspects of the proposed methodology, the design and construction of a fiber-optical measuring system and the selection of the optimal frequencies to perform the accurate lifetime measurements are discussed. Finally, the performance of the proposed measurement method has been assessed in the determination of the triplet-lifetime values of the metal chelate Al-ferron immobilized in an inorganic sol–gel support (an oxygen indicator which displays a strong fluorescence emission overlapping significantly with the measured phosphorescence emission).</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.snb.2005.02.054</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0925-4005
ispartof Sensors and actuators. B, Chemical, 2006-01, Vol.113 (1), p.249-258
issn 0925-4005
1873-3077
language eng
recordid cdi_proquest_miscellaneous_28644431
source ScienceDirect Freedom Collection
subjects Emission
Emission analysis
Excitation
Fiber optics
Fluorescence
Frequency-domain
Optical fibers
Phase shift
Phosphorescence
Quenching
title Determination of phosphorescence lifetimes in the presence of high background signals using phase-shift measurements
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T18%3A17%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20phosphorescence%20lifetimes%20in%20the%20presence%20of%20high%20background%20signals%20using%20phase-shift%20measurements&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Valledor,%20Marta&rft.date=2006-01-17&rft.volume=113&rft.issue=1&rft.spage=249&rft.epage=258&rft.pages=249-258&rft.issn=0925-4005&rft.eissn=1873-3077&rft_id=info:doi/10.1016/j.snb.2005.02.054&rft_dat=%3Cproquest_cross%3E28644431%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c361t-ededf50734d473bd96b89b8bd79fcf63b52d28c34f0bf7b9442224d6441be5d93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1082192792&rft_id=info:pmid/&rfr_iscdi=true