Loading…
Comparison among three lung ultrasound scores used to predict the need for surfactant replacement therapy: a retrospective diagnostic accuracy study in a cohort of preterm infants
Lung ultrasound (LU) has emerged as the imaging technique of choice for the assessment of neonates with respiratory distress syndrome (RDS) at the bedside. Scoring systems were developed to quantify RDS severity and to predict the need for surfactant administration. There is no data on the compariso...
Saved in:
Published in: | European journal of pediatrics 2023-12, Vol.182 (12), p.5375-5383 |
---|---|
Main Authors: | , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Lung ultrasound (LU) has emerged as the imaging technique of choice for the assessment of neonates with respiratory distress syndrome (RDS) at the bedside. Scoring systems were developed to quantify RDS severity and to predict the need for surfactant administration. There is no data on the comparison of the three main LU scores (LUS) proposed by Brat, Raimondi and Rodriguez-Fanjul. Moreover, there is not enough evidence to recommend which score and which cut-off has the best ability to predict surfactant need. The three LUS were compared in terms of ability to predict the need for surfactant and reproducibility in a cohort of very preterm infants. This was an observational, retrospective, multicenter study. Neonates below 32 weeks of gestational age with RDS, on non-invasive ventilation with a LU performed prior to surfactant administration (1–3 h of life) were included. Brat, Raimondi, and Rodriguez-Fanjul’s scores were calculated for each patient. Receiver-operating characteristic (ROC) curve analysis was used to assess the ability to predict surfactant administration. K-Cohen test, Bland–Altman, and intraclass correlation coefficients were used to assess the intra and interobserver variability. Fifty-four preterm infants were enrolled. Brat, Raimondi, and Rodriguez-Fanjul scores showed a strong ability to predict the need for surfactant: the AUCs were 0.85 (95% CI 0.74–0.96), 0.85 (95% CI 0.75–0.96), and 0.79 (95% CI 0.67–0.92), respectively. No significant differences have been found between the AUCs using the DeLong test. Brat and Raimondi’s scores had an optimal cut-off value > 8, while the Rodriguez-Fanjul’s score > 10. The k-Cohen values of intraobserver agreement for Brat, Raimondi, and Rodriguez-Fanjul’s scores were 0.896 (0.698–1.000), 1.000 (1.000–1.000), and 0.922 (0.767–1.000), respectively. The k-Cohen values of interobserver agreement were 0.896 (0.698–1.000), 0.911 (0.741–1.000), and 0.833 (0.612–1.000), respectively.
Conclusions
: The three LUS had an excellent ability to predict the need for surfactant and an optimal intra and interobserver agreement. The differences found between the three scores are minimal with negligible clinical implications. Since the optimal cut-off value differed, the same score should be used consistently within the same center.
What is Known:
• Lung ultrasound is a useful bedside imaging tool that should be used in the assessment of neonates with RDS
• Scoring systems or lung ultrasound scores allow to quantify |
---|---|
ISSN: | 1432-1076 0340-6199 1432-1076 |