Biomechanical Comparison of Distal Femoral Fracture Fixation: Polyaxial vs. Uniaxial Locking Screws with Different Blocking Screw Configurations in Retrograde Femoral Nailing
Introduction: Clinical studies have indicated reduced reliance on blocking screws with the introduction of polyaxial locking nails, yet the biomechanical superiority of polyaxial locking over blocking screws remains unverified, specifically for distal dia-metaphyseal femur fractures. Hypothesis: We...
Saved in:
Published in: | Orthopaedics & traumatology, surgery & research surgery & research, 2024-02, Vol.110 (1), p.103695-103695, Article 103695 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c307t-97aa64ed5ffb12971712cf325c6038bc1d8940221ef7e1fdb7b9fd861baa2a143 |
container_end_page | 103695 |
container_issue | 1 |
container_start_page | 103695 |
container_title | Orthopaedics & traumatology, surgery & research |
container_volume | 110 |
creator | Batar, Suat Söylemez, Mehmet Salih Bozdağ, S Ergün Yaman, Enis Kemah, Bahattin Poyanlı, Oğuz S |
description | Introduction: Clinical studies have indicated reduced reliance on blocking screws with the introduction of polyaxial locking nails, yet the biomechanical superiority of polyaxial locking over blocking screws remains unverified, specifically for distal dia-metaphyseal femur fractures.
Hypothesis: We hypothesized that the combination of multiaxial locking using three screws and parallel locking reinforced by two blocking screws would result in superior outcomes compared to utilizing only parallel locking with two screws and one blocking screw.
Materials and Methods: Third-generation custom-made femur models representing AO/OTA 32 A1.2 dia-metaphyseal comminuted oblique fractures were divided into four groups (n=10/group). Group A employed distal fixation with three 4.5-mm polyaxial screws. Group B used two parallel locking screws and two blocking screws, Group C used two parallel locking screws and one blocking screw, and Group D used only two parallel screws. Specimens underwent axial and torsional load testing to assess fatigue strength, ultimate strength, axial stiffness (N/mm), torsional stiffness (N·mm/deg), axial load to failure (N), torsional load to failure (N·mm), coronal and sagittal angulations, and fracture site collapse.
Results: Group C exhibited statistically superior torsional stiffness compared to Groups B and D (P=0.039 and P=0.034, respectively). Axial load to failure was highest in Group B and lowest in Group D (P=0.032). Group C demonstrated the highest torsional strength, while Group B exhibited the lowest (P=0.006). Coronal displacement was greatest in Group B, while Group A showed the highest resistance (P=0.009). Group A demonstrated the greatest resistance to fracture site collapse, with the weakest specimens observed in Groups B and C (P=0.01).
Discussion: The performance of a single laterally positioned blocking screw is comparable to using two blocking screws. Medial positioning of a second blocking screw is unnecessary for stability enhancement. Multiaxial locking prevents fracture site collapse and coronal plane angulation more effectively than other methods. Multiaxial locking and/or parallel screws with a single laterally positioned blocking screw provide superior stiffness and stability for treating unstable dia-metaphyseal distal femoral fractures.
Level of evidence: N/A. |
doi_str_mv | 10.1016/j.otsr.2023.103695 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2872181087</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1877056823002050</els_id><sourcerecordid>2872181087</sourcerecordid><originalsourceid>FETCH-LOGICAL-c307t-97aa64ed5ffb12971712cf325c6038bc1d8940221ef7e1fdb7b9fd861baa2a143</originalsourceid><addsrcrecordid>eNp9kU1vEzEQhi0EoqXwBzggH7kk9Uey3kVcaCAFKQIE9Gx5veN0wq4dbG8__hS_EYctVU-cxp5532c0egl5ydmcM16d7uYhpzgXTMjSkFWzfESOea3UjC2r-vGD9xF5ltKOsariUjwlR1KpWi5EdUx-n2EYwF4aj9b0dBWGvYmYgqfB0feYcmmuYQjxUKOxeYxA13hjMgb_hn4N_a25wTK8SnN64XH6bIL9iX5Lv9sI14leY74sMOcggs_0rH84Lju9w-0Y_yITRU-_QY5hG00H97s_G-yL5Tl54kyf4MVdPSEX6w8_Vh9nmy_nn1bvNjMrmcqzRhlTLaBbOtdy0SiuuLBOiqWtmKxby7u6WTAhODgF3HWtahvX1RVvjRGGL-QJeT1x9zH8GiFlPWCy0PfGQxiTFrUSvOasVkUqJqmNIaUITu8jDibeas70ISe904ec9CEnPeVUTK_u-GM7QHdv-RdMEbydBFCuvEKIOlkEb6HDCDbrLuD_-H8AfFeoEw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2872181087</pqid></control><display><type>article</type><title>Biomechanical Comparison of Distal Femoral Fracture Fixation: Polyaxial vs. Uniaxial Locking Screws with Different Blocking Screw Configurations in Retrograde Femoral Nailing</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Batar, Suat ; Söylemez, Mehmet Salih ; Bozdağ, S Ergün ; Yaman, Enis ; Kemah, Bahattin ; Poyanlı, Oğuz S</creator><creatorcontrib>Batar, Suat ; Söylemez, Mehmet Salih ; Bozdağ, S Ergün ; Yaman, Enis ; Kemah, Bahattin ; Poyanlı, Oğuz S</creatorcontrib><description>Introduction: Clinical studies have indicated reduced reliance on blocking screws with the introduction of polyaxial locking nails, yet the biomechanical superiority of polyaxial locking over blocking screws remains unverified, specifically for distal dia-metaphyseal femur fractures.
Hypothesis: We hypothesized that the combination of multiaxial locking using three screws and parallel locking reinforced by two blocking screws would result in superior outcomes compared to utilizing only parallel locking with two screws and one blocking screw.
Materials and Methods: Third-generation custom-made femur models representing AO/OTA 32 A1.2 dia-metaphyseal comminuted oblique fractures were divided into four groups (n=10/group). Group A employed distal fixation with three 4.5-mm polyaxial screws. Group B used two parallel locking screws and two blocking screws, Group C used two parallel locking screws and one blocking screw, and Group D used only two parallel screws. Specimens underwent axial and torsional load testing to assess fatigue strength, ultimate strength, axial stiffness (N/mm), torsional stiffness (N·mm/deg), axial load to failure (N), torsional load to failure (N·mm), coronal and sagittal angulations, and fracture site collapse.
Results: Group C exhibited statistically superior torsional stiffness compared to Groups B and D (P=0.039 and P=0.034, respectively). Axial load to failure was highest in Group B and lowest in Group D (P=0.032). Group C demonstrated the highest torsional strength, while Group B exhibited the lowest (P=0.006). Coronal displacement was greatest in Group B, while Group A showed the highest resistance (P=0.009). Group A demonstrated the greatest resistance to fracture site collapse, with the weakest specimens observed in Groups B and C (P=0.01).
Discussion: The performance of a single laterally positioned blocking screw is comparable to using two blocking screws. Medial positioning of a second blocking screw is unnecessary for stability enhancement. Multiaxial locking prevents fracture site collapse and coronal plane angulation more effectively than other methods. Multiaxial locking and/or parallel screws with a single laterally positioned blocking screw provide superior stiffness and stability for treating unstable dia-metaphyseal distal femoral fractures.
Level of evidence: N/A.</description><identifier>ISSN: 1877-0568</identifier><identifier>EISSN: 1877-0568</identifier><identifier>DOI: 10.1016/j.otsr.2023.103695</identifier><identifier>PMID: 37783426</identifier><language>eng</language><publisher>France: Elsevier Masson SAS</publisher><subject>Biomechanical Phenomena ; biomechanics ; blocking screw ; Bone Plates ; Bone Screws ; Distal femoral fracture ; Femoral Fractures - diagnostic imaging ; Femoral Fractures - surgery ; Femoral Fractures, Distal ; Femur ; Fracture Fixation, Internal - methods ; Fracture Fixation, Intramedullary - methods ; Fractures, Comminuted - diagnostic imaging ; Fractures, Comminuted - surgery ; Humans ; polyaxial locking screw ; retrograde intramedullary nail</subject><ispartof>Orthopaedics & traumatology, surgery & research, 2024-02, Vol.110 (1), p.103695-103695, Article 103695</ispartof><rights>2023 Elsevier Masson SAS</rights><rights>Copyright © 2023 Elsevier Masson SAS. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c307t-97aa64ed5ffb12971712cf325c6038bc1d8940221ef7e1fdb7b9fd861baa2a143</cites><orcidid>0000-0002-0828-0145 ; 0009-0006-1975-4904 ; 0000-0002-4795-4309 ; 0000-0002-6952-9493</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37783426$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Batar, Suat</creatorcontrib><creatorcontrib>Söylemez, Mehmet Salih</creatorcontrib><creatorcontrib>Bozdağ, S Ergün</creatorcontrib><creatorcontrib>Yaman, Enis</creatorcontrib><creatorcontrib>Kemah, Bahattin</creatorcontrib><creatorcontrib>Poyanlı, Oğuz S</creatorcontrib><title>Biomechanical Comparison of Distal Femoral Fracture Fixation: Polyaxial vs. Uniaxial Locking Screws with Different Blocking Screw Configurations in Retrograde Femoral Nailing</title><title>Orthopaedics & traumatology, surgery & research</title><addtitle>Orthop Traumatol Surg Res</addtitle><description>Introduction: Clinical studies have indicated reduced reliance on blocking screws with the introduction of polyaxial locking nails, yet the biomechanical superiority of polyaxial locking over blocking screws remains unverified, specifically for distal dia-metaphyseal femur fractures.
Hypothesis: We hypothesized that the combination of multiaxial locking using three screws and parallel locking reinforced by two blocking screws would result in superior outcomes compared to utilizing only parallel locking with two screws and one blocking screw.
Materials and Methods: Third-generation custom-made femur models representing AO/OTA 32 A1.2 dia-metaphyseal comminuted oblique fractures were divided into four groups (n=10/group). Group A employed distal fixation with three 4.5-mm polyaxial screws. Group B used two parallel locking screws and two blocking screws, Group C used two parallel locking screws and one blocking screw, and Group D used only two parallel screws. Specimens underwent axial and torsional load testing to assess fatigue strength, ultimate strength, axial stiffness (N/mm), torsional stiffness (N·mm/deg), axial load to failure (N), torsional load to failure (N·mm), coronal and sagittal angulations, and fracture site collapse.
Results: Group C exhibited statistically superior torsional stiffness compared to Groups B and D (P=0.039 and P=0.034, respectively). Axial load to failure was highest in Group B and lowest in Group D (P=0.032). Group C demonstrated the highest torsional strength, while Group B exhibited the lowest (P=0.006). Coronal displacement was greatest in Group B, while Group A showed the highest resistance (P=0.009). Group A demonstrated the greatest resistance to fracture site collapse, with the weakest specimens observed in Groups B and C (P=0.01).
Discussion: The performance of a single laterally positioned blocking screw is comparable to using two blocking screws. Medial positioning of a second blocking screw is unnecessary for stability enhancement. Multiaxial locking prevents fracture site collapse and coronal plane angulation more effectively than other methods. Multiaxial locking and/or parallel screws with a single laterally positioned blocking screw provide superior stiffness and stability for treating unstable dia-metaphyseal distal femoral fractures.
Level of evidence: N/A.</description><subject>Biomechanical Phenomena</subject><subject>biomechanics</subject><subject>blocking screw</subject><subject>Bone Plates</subject><subject>Bone Screws</subject><subject>Distal femoral fracture</subject><subject>Femoral Fractures - diagnostic imaging</subject><subject>Femoral Fractures - surgery</subject><subject>Femoral Fractures, Distal</subject><subject>Femur</subject><subject>Fracture Fixation, Internal - methods</subject><subject>Fracture Fixation, Intramedullary - methods</subject><subject>Fractures, Comminuted - diagnostic imaging</subject><subject>Fractures, Comminuted - surgery</subject><subject>Humans</subject><subject>polyaxial locking screw</subject><subject>retrograde intramedullary nail</subject><issn>1877-0568</issn><issn>1877-0568</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kU1vEzEQhi0EoqXwBzggH7kk9Uey3kVcaCAFKQIE9Gx5veN0wq4dbG8__hS_EYctVU-cxp5532c0egl5ydmcM16d7uYhpzgXTMjSkFWzfESOea3UjC2r-vGD9xF5ltKOsariUjwlR1KpWi5EdUx-n2EYwF4aj9b0dBWGvYmYgqfB0feYcmmuYQjxUKOxeYxA13hjMgb_hn4N_a25wTK8SnN64XH6bIL9iX5Lv9sI14leY74sMOcggs_0rH84Lju9w-0Y_yITRU-_QY5hG00H97s_G-yL5Tl54kyf4MVdPSEX6w8_Vh9nmy_nn1bvNjMrmcqzRhlTLaBbOtdy0SiuuLBOiqWtmKxby7u6WTAhODgF3HWtahvX1RVvjRGGL-QJeT1x9zH8GiFlPWCy0PfGQxiTFrUSvOasVkUqJqmNIaUITu8jDibeas70ISe904ec9CEnPeVUTK_u-GM7QHdv-RdMEbydBFCuvEKIOlkEb6HDCDbrLuD_-H8AfFeoEw</recordid><startdate>202402</startdate><enddate>202402</enddate><creator>Batar, Suat</creator><creator>Söylemez, Mehmet Salih</creator><creator>Bozdağ, S Ergün</creator><creator>Yaman, Enis</creator><creator>Kemah, Bahattin</creator><creator>Poyanlı, Oğuz S</creator><general>Elsevier Masson SAS</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-0828-0145</orcidid><orcidid>https://orcid.org/0009-0006-1975-4904</orcidid><orcidid>https://orcid.org/0000-0002-4795-4309</orcidid><orcidid>https://orcid.org/0000-0002-6952-9493</orcidid></search><sort><creationdate>202402</creationdate><title>Biomechanical Comparison of Distal Femoral Fracture Fixation: Polyaxial vs. Uniaxial Locking Screws with Different Blocking Screw Configurations in Retrograde Femoral Nailing</title><author>Batar, Suat ; Söylemez, Mehmet Salih ; Bozdağ, S Ergün ; Yaman, Enis ; Kemah, Bahattin ; Poyanlı, Oğuz S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c307t-97aa64ed5ffb12971712cf325c6038bc1d8940221ef7e1fdb7b9fd861baa2a143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Biomechanical Phenomena</topic><topic>biomechanics</topic><topic>blocking screw</topic><topic>Bone Plates</topic><topic>Bone Screws</topic><topic>Distal femoral fracture</topic><topic>Femoral Fractures - diagnostic imaging</topic><topic>Femoral Fractures - surgery</topic><topic>Femoral Fractures, Distal</topic><topic>Femur</topic><topic>Fracture Fixation, Internal - methods</topic><topic>Fracture Fixation, Intramedullary - methods</topic><topic>Fractures, Comminuted - diagnostic imaging</topic><topic>Fractures, Comminuted - surgery</topic><topic>Humans</topic><topic>polyaxial locking screw</topic><topic>retrograde intramedullary nail</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Batar, Suat</creatorcontrib><creatorcontrib>Söylemez, Mehmet Salih</creatorcontrib><creatorcontrib>Bozdağ, S Ergün</creatorcontrib><creatorcontrib>Yaman, Enis</creatorcontrib><creatorcontrib>Kemah, Bahattin</creatorcontrib><creatorcontrib>Poyanlı, Oğuz S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Orthopaedics & traumatology, surgery & research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Batar, Suat</au><au>Söylemez, Mehmet Salih</au><au>Bozdağ, S Ergün</au><au>Yaman, Enis</au><au>Kemah, Bahattin</au><au>Poyanlı, Oğuz S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biomechanical Comparison of Distal Femoral Fracture Fixation: Polyaxial vs. Uniaxial Locking Screws with Different Blocking Screw Configurations in Retrograde Femoral Nailing</atitle><jtitle>Orthopaedics & traumatology, surgery & research</jtitle><addtitle>Orthop Traumatol Surg Res</addtitle><date>2024-02</date><risdate>2024</risdate><volume>110</volume><issue>1</issue><spage>103695</spage><epage>103695</epage><pages>103695-103695</pages><artnum>103695</artnum><issn>1877-0568</issn><eissn>1877-0568</eissn><abstract>Introduction: Clinical studies have indicated reduced reliance on blocking screws with the introduction of polyaxial locking nails, yet the biomechanical superiority of polyaxial locking over blocking screws remains unverified, specifically for distal dia-metaphyseal femur fractures.
Hypothesis: We hypothesized that the combination of multiaxial locking using three screws and parallel locking reinforced by two blocking screws would result in superior outcomes compared to utilizing only parallel locking with two screws and one blocking screw.
Materials and Methods: Third-generation custom-made femur models representing AO/OTA 32 A1.2 dia-metaphyseal comminuted oblique fractures were divided into four groups (n=10/group). Group A employed distal fixation with three 4.5-mm polyaxial screws. Group B used two parallel locking screws and two blocking screws, Group C used two parallel locking screws and one blocking screw, and Group D used only two parallel screws. Specimens underwent axial and torsional load testing to assess fatigue strength, ultimate strength, axial stiffness (N/mm), torsional stiffness (N·mm/deg), axial load to failure (N), torsional load to failure (N·mm), coronal and sagittal angulations, and fracture site collapse.
Results: Group C exhibited statistically superior torsional stiffness compared to Groups B and D (P=0.039 and P=0.034, respectively). Axial load to failure was highest in Group B and lowest in Group D (P=0.032). Group C demonstrated the highest torsional strength, while Group B exhibited the lowest (P=0.006). Coronal displacement was greatest in Group B, while Group A showed the highest resistance (P=0.009). Group A demonstrated the greatest resistance to fracture site collapse, with the weakest specimens observed in Groups B and C (P=0.01).
Discussion: The performance of a single laterally positioned blocking screw is comparable to using two blocking screws. Medial positioning of a second blocking screw is unnecessary for stability enhancement. Multiaxial locking prevents fracture site collapse and coronal plane angulation more effectively than other methods. Multiaxial locking and/or parallel screws with a single laterally positioned blocking screw provide superior stiffness and stability for treating unstable dia-metaphyseal distal femoral fractures.
Level of evidence: N/A.</abstract><cop>France</cop><pub>Elsevier Masson SAS</pub><pmid>37783426</pmid><doi>10.1016/j.otsr.2023.103695</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-0828-0145</orcidid><orcidid>https://orcid.org/0009-0006-1975-4904</orcidid><orcidid>https://orcid.org/0000-0002-4795-4309</orcidid><orcidid>https://orcid.org/0000-0002-6952-9493</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1877-0568 |
ispartof | Orthopaedics & traumatology, surgery & research, 2024-02, Vol.110 (1), p.103695-103695, Article 103695 |
issn | 1877-0568 1877-0568 |
language | eng |
recordid | cdi_proquest_miscellaneous_2872181087 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Biomechanical Phenomena biomechanics blocking screw Bone Plates Bone Screws Distal femoral fracture Femoral Fractures - diagnostic imaging Femoral Fractures - surgery Femoral Fractures, Distal Femur Fracture Fixation, Internal - methods Fracture Fixation, Intramedullary - methods Fractures, Comminuted - diagnostic imaging Fractures, Comminuted - surgery Humans polyaxial locking screw retrograde intramedullary nail |
title | Biomechanical Comparison of Distal Femoral Fracture Fixation: Polyaxial vs. Uniaxial Locking Screws with Different Blocking Screw Configurations in Retrograde Femoral Nailing |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T22%3A16%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biomechanical%20Comparison%20of%20Distal%20Femoral%20Fracture%20Fixation:%20Polyaxial%20vs.%20Uniaxial%20Locking%20Screws%20with%20Different%20Blocking%20Screw%20Configurations%20in%20Retrograde%20Femoral%20Nailing&rft.jtitle=Orthopaedics%20&%20traumatology,%20surgery%20&%20research&rft.au=Batar,%20Suat&rft.date=2024-02&rft.volume=110&rft.issue=1&rft.spage=103695&rft.epage=103695&rft.pages=103695-103695&rft.artnum=103695&rft.issn=1877-0568&rft.eissn=1877-0568&rft_id=info:doi/10.1016/j.otsr.2023.103695&rft_dat=%3Cproquest_cross%3E2872181087%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c307t-97aa64ed5ffb12971712cf325c6038bc1d8940221ef7e1fdb7b9fd861baa2a143%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2872181087&rft_id=info:pmid/37783426&rfr_iscdi=true |