Loading…
An optical IR-source and CO(2)-chamber system for CO(2 ) measurements
A new silicon IR source and CO(2)-chamber system for measurement of CO(2) concentration is presented. The micromachined IR-source, which consists of four groups of polysilicon filaments coated with silicon nitride suspended across a KOH-etched cavity, is used to generate two switched "sample&qu...
Saved in:
Published in: | Journal of microelectromechanical systems 2000-12, Vol.9 (4), p.509-516 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 516 |
container_issue | 4 |
container_start_page | 509 |
container_title | Journal of microelectromechanical systems |
container_volume | 9 |
creator | Corman, T Kalvesten, E Huiku, M Weckstrom, K Merilainen, P T Stemme, G |
description | A new silicon IR source and CO(2)-chamber system for measurement of CO(2) concentration is presented. The micromachined IR-source, which consists of four groups of polysilicon filaments coated with silicon nitride suspended across a KOH-etched cavity, is used to generate two switched "sample" and "reference" beams. The electrically modulated sources present a modulation time of 10 ms and a power consumption of 1 W. The CO(2) chambers, placed beneath the reference sources, are used to produce a reference beam for long term stability and compensation against cuvette window contamination. They consist of 1-mm-deep micromachined cavities in which CO(2) is encapsulated during an overpressure anodic bonding procedure. Silicon dioxide is used as an antireflective coating to optimize the filter's optical characteristics. Numerical simulations of the filters are presented and show good agreement with the measurements. The IR sources and the CO(2) filters are both fabricated at wafer level. Using the presented IR-sensor system, measurements with a 9-mm-wide test channel show high CO(2)-sensitivity for CO(2) concentrations between 0 and 10% confirming that the stringent requirements for this respirator application can be fulfilled |
doi_str_mv | 10.1109/84.896773 |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_28739689</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>28739689</sourcerecordid><originalsourceid>FETCH-LOGICAL-p629-de69dff684b0f90e44f79e9f2078cb233521ff12dcb57d6eb6568a8ad002d1693</originalsourceid><addsrcrecordid>eNqNjL1OwzAYAD2ARCkMvIEnRAcX_-WzPVZRKZUqVULdK8f-LIriJMTJwNsjAQ_AdMOdjpAHwddCcPds9do6MEZdkYXglWFGVOaG3JbywbnQ2sKCbDcd7YfpEnxL92-s9PMYkPou0vr4JFcsvPvc4EjLV5kw09SPP4KuaEZf5hEzdlO5I9fJtwXv_7gkp5ftqX5lh-NuX28ObADpWERwMSWwuuHJcdQ6GYcuSW5saKRSlRQpCRlDU5kI2EAF1lsfOZdRgFNL8vi7Hcb-c8YynfOlBGxb32E_l7O0Rjmw_wk1gJZGfQPvOlYx</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28466427</pqid></control><display><type>article</type><title>An optical IR-source and CO(2)-chamber system for CO(2 ) measurements</title><source>IEEE Xplore (Online service)</source><creator>Corman, T ; Kalvesten, E ; Huiku, M ; Weckstrom, K ; Merilainen, P T ; Stemme, G</creator><creatorcontrib>Corman, T ; Kalvesten, E ; Huiku, M ; Weckstrom, K ; Merilainen, P T ; Stemme, G</creatorcontrib><description>A new silicon IR source and CO(2)-chamber system for measurement of CO(2) concentration is presented. The micromachined IR-source, which consists of four groups of polysilicon filaments coated with silicon nitride suspended across a KOH-etched cavity, is used to generate two switched "sample" and "reference" beams. The electrically modulated sources present a modulation time of 10 ms and a power consumption of 1 W. The CO(2) chambers, placed beneath the reference sources, are used to produce a reference beam for long term stability and compensation against cuvette window contamination. They consist of 1-mm-deep micromachined cavities in which CO(2) is encapsulated during an overpressure anodic bonding procedure. Silicon dioxide is used as an antireflective coating to optimize the filter's optical characteristics. Numerical simulations of the filters are presented and show good agreement with the measurements. The IR sources and the CO(2) filters are both fabricated at wafer level. Using the presented IR-sensor system, measurements with a 9-mm-wide test channel show high CO(2)-sensitivity for CO(2) concentrations between 0 and 10% confirming that the stringent requirements for this respirator application can be fulfilled</description><identifier>ISSN: 1057-7157</identifier><identifier>DOI: 10.1109/84.896773</identifier><language>eng</language><ispartof>Journal of microelectromechanical systems, 2000-12, Vol.9 (4), p.509-516</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Corman, T</creatorcontrib><creatorcontrib>Kalvesten, E</creatorcontrib><creatorcontrib>Huiku, M</creatorcontrib><creatorcontrib>Weckstrom, K</creatorcontrib><creatorcontrib>Merilainen, P T</creatorcontrib><creatorcontrib>Stemme, G</creatorcontrib><title>An optical IR-source and CO(2)-chamber system for CO(2 ) measurements</title><title>Journal of microelectromechanical systems</title><description>A new silicon IR source and CO(2)-chamber system for measurement of CO(2) concentration is presented. The micromachined IR-source, which consists of four groups of polysilicon filaments coated with silicon nitride suspended across a KOH-etched cavity, is used to generate two switched "sample" and "reference" beams. The electrically modulated sources present a modulation time of 10 ms and a power consumption of 1 W. The CO(2) chambers, placed beneath the reference sources, are used to produce a reference beam for long term stability and compensation against cuvette window contamination. They consist of 1-mm-deep micromachined cavities in which CO(2) is encapsulated during an overpressure anodic bonding procedure. Silicon dioxide is used as an antireflective coating to optimize the filter's optical characteristics. Numerical simulations of the filters are presented and show good agreement with the measurements. The IR sources and the CO(2) filters are both fabricated at wafer level. Using the presented IR-sensor system, measurements with a 9-mm-wide test channel show high CO(2)-sensitivity for CO(2) concentrations between 0 and 10% confirming that the stringent requirements for this respirator application can be fulfilled</description><issn>1057-7157</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNqNjL1OwzAYAD2ARCkMvIEnRAcX_-WzPVZRKZUqVULdK8f-LIriJMTJwNsjAQ_AdMOdjpAHwddCcPds9do6MEZdkYXglWFGVOaG3JbywbnQ2sKCbDcd7YfpEnxL92-s9PMYkPou0vr4JFcsvPvc4EjLV5kw09SPP4KuaEZf5hEzdlO5I9fJtwXv_7gkp5ftqX5lh-NuX28ObADpWERwMSWwuuHJcdQ6GYcuSW5saKRSlRQpCRlDU5kI2EAF1lsfOZdRgFNL8vi7Hcb-c8YynfOlBGxb32E_l7O0Rjmw_wk1gJZGfQPvOlYx</recordid><startdate>20001201</startdate><enddate>20001201</enddate><creator>Corman, T</creator><creator>Kalvesten, E</creator><creator>Huiku, M</creator><creator>Weckstrom, K</creator><creator>Merilainen, P T</creator><creator>Stemme, G</creator><scope>7SP</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><scope>7QQ</scope><scope>JG9</scope></search><sort><creationdate>20001201</creationdate><title>An optical IR-source and CO(2)-chamber system for CO(2 ) measurements</title><author>Corman, T ; Kalvesten, E ; Huiku, M ; Weckstrom, K ; Merilainen, P T ; Stemme, G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p629-de69dff684b0f90e44f79e9f2078cb233521ff12dcb57d6eb6568a8ad002d1693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Corman, T</creatorcontrib><creatorcontrib>Kalvesten, E</creatorcontrib><creatorcontrib>Huiku, M</creatorcontrib><creatorcontrib>Weckstrom, K</creatorcontrib><creatorcontrib>Merilainen, P T</creatorcontrib><creatorcontrib>Stemme, G</creatorcontrib><collection>Electronics & Communications Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Ceramic Abstracts</collection><collection>Materials Research Database</collection><jtitle>Journal of microelectromechanical systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Corman, T</au><au>Kalvesten, E</au><au>Huiku, M</au><au>Weckstrom, K</au><au>Merilainen, P T</au><au>Stemme, G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An optical IR-source and CO(2)-chamber system for CO(2 ) measurements</atitle><jtitle>Journal of microelectromechanical systems</jtitle><date>2000-12-01</date><risdate>2000</risdate><volume>9</volume><issue>4</issue><spage>509</spage><epage>516</epage><pages>509-516</pages><issn>1057-7157</issn><abstract>A new silicon IR source and CO(2)-chamber system for measurement of CO(2) concentration is presented. The micromachined IR-source, which consists of four groups of polysilicon filaments coated with silicon nitride suspended across a KOH-etched cavity, is used to generate two switched "sample" and "reference" beams. The electrically modulated sources present a modulation time of 10 ms and a power consumption of 1 W. The CO(2) chambers, placed beneath the reference sources, are used to produce a reference beam for long term stability and compensation against cuvette window contamination. They consist of 1-mm-deep micromachined cavities in which CO(2) is encapsulated during an overpressure anodic bonding procedure. Silicon dioxide is used as an antireflective coating to optimize the filter's optical characteristics. Numerical simulations of the filters are presented and show good agreement with the measurements. The IR sources and the CO(2) filters are both fabricated at wafer level. Using the presented IR-sensor system, measurements with a 9-mm-wide test channel show high CO(2)-sensitivity for CO(2) concentrations between 0 and 10% confirming that the stringent requirements for this respirator application can be fulfilled</abstract><doi>10.1109/84.896773</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1057-7157 |
ispartof | Journal of microelectromechanical systems, 2000-12, Vol.9 (4), p.509-516 |
issn | 1057-7157 |
language | eng |
recordid | cdi_proquest_miscellaneous_28739689 |
source | IEEE Xplore (Online service) |
title | An optical IR-source and CO(2)-chamber system for CO(2 ) measurements |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T00%3A37%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20optical%20IR-source%20and%20CO(2)-chamber%20system%20for%20CO(2%20)%20measurements&rft.jtitle=Journal%20of%20microelectromechanical%20systems&rft.au=Corman,%20T&rft.date=2000-12-01&rft.volume=9&rft.issue=4&rft.spage=509&rft.epage=516&rft.pages=509-516&rft.issn=1057-7157&rft_id=info:doi/10.1109/84.896773&rft_dat=%3Cproquest%3E28739689%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p629-de69dff684b0f90e44f79e9f2078cb233521ff12dcb57d6eb6568a8ad002d1693%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=28466427&rft_id=info:pmid/&rfr_iscdi=true |