Loading…
Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine arthroplasty model. Part II: in vivo investigation
The polyurethane (PU) elastomer Corethane 80A (Corvita) is being considered as the acetabular bearing material in a novel total replacement hip joint. Its biostability was investigated in vitro (Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine a...
Saved in:
Published in: | Biomaterials 2005-02, Vol.26 (6), p.633-643 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The polyurethane (PU) elastomer Corethane 80A (Corvita) is being considered as the acetabular bearing material in a novel total replacement hip joint. Its biostability was investigated in vitro (Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine arthroplasty model. Part I: material selection and evaluation, Biomaterials, in press) together with three other commercially available biomedical PUs: Pellethane 2363-80A (DOW Chemical), a polyhexamethylene oxide based PU, PHMO-PU (CSIRO, not supplied as a commercial product) and ChronoFlex AL-80A (CardioTech). From the in vitro studies, Corethane 80A displayed the best overall resistance to hydrolysis, ESC, MIO and calcification, followed by ChronoFlex 80A and PHMO-PU, with Pellethane 80A being the least stable. Building on the in vitro investigation, the follow-up in vivo study (reported here) assessed Corethane 80A as the bearing layer in a prototype compliant layer acetabular cup, in a fully functioning ovine total hip arthoplasty (THA) model. PU degradation in the retrieved cups was analysed using a range of analytical and physical-testing methods including mechanical testing, differential scanning calorimetry, Fourier transform infrared spectroscopy and environmental scanning electron microscopy. The Corethane 80A functioned well in the THA model, with the bearing surfaces of the retrieved hip cups showing no significant evidence of biodegradation or wear damage after 3 years in vivo. The findings in this study provide compelling evidence for the biostability and effectiveness of acetabular cups incorporating a Corethane 80A compliant bearing layer. |
---|---|
ISSN: | 0142-9612 1878-5905 |
DOI: | 10.1016/j.biomaterials.2004.02.064 |