A Safe Technique for Excising the Perpendicular Plate of the Ethmoid Bone in Patients with Crooked Nose: A Finite Element Analysis

Background Correction of the crooked nose, especially the perpendicular plate of the ethmoid bone, has the potential to cause skull base injury. At present, the safe and effective method for perpendicular plate resection has not been clearly defined through biomechanics. Method CT scan data of 48 pa...

Full description

Saved in:
Bibliographic Details
Published in:Aesthetic plastic surgery 2024-03, Vol.48 (6), p.1084-1093
Main Authors: Sun, Yi-Dan, Wu, Si-Qiao, Wang, Zheng, Zhao, Zhen-Min, An, Yang
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c326t-9afd36dca5afd88972dc036376caf14b4769df034b059bd9f91bf13ee42d2e7d3
container_end_page 1093
container_issue 6
container_start_page 1084
container_title Aesthetic plastic surgery
container_volume 48
creator Sun, Yi-Dan
Wu, Si-Qiao
Wang, Zheng
Zhao, Zhen-Min
An, Yang
description Background Correction of the crooked nose, especially the perpendicular plate of the ethmoid bone, has the potential to cause skull base injury. At present, the safe and effective method for perpendicular plate resection has not been clearly defined through biomechanics. Method CT scan data of 48 patients with crooked nose and deviated nasal septum were divided into C-type, angular deformity-type, and S-type based on the morphology of the 3D model. Different types of finite element models of the nasal bony septum and skull base were established. The osteotomy depth, angle, and force mode of the PPE resection were simulated by assembling different working conditions for the models. The von Mises stress of the anterior cranial fossa was observed. Results When the osteotomy line length was 0.5 cm, the angle was at 30° to the Frankfurt plane, and 50 N·mm torque was applied, the von Mises stress of the skull base was minimal in the four models, showing 0.049 MPa (C-type), 0.082 MPa (S-type), 0.128 MPa (angular deformity-type), and 0.021 MPa (control model). The maximum von Mises stress values were found at the skull base when the osteotomy line was 1.5 cm, the angle was 50°, and the force was 10 N along the X-axis, showing 0.349 MPa (C-type), 0.698 MPa (S-type), 0.451 MPa (angular deformity-type), and 0.149 MPa (control model). Conclusion The use of smaller resection angle with the Frankfurt plane, conservative resection depth, and torsion force can better reduce the stress value at the skull base and reduce the risk of basicranial fracture. It is a safe and effective technique for perpendicular plate resection of the ethmoid bone in the correction of crooked nose. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
doi_str_mv 10.1007/s00266-023-03712-5
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2886939973</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2886939973</sourcerecordid><originalsourceid>FETCH-LOGICAL-c326t-9afd36dca5afd88972dc036376caf14b4769df034b059bd9f91bf13ee42d2e7d3</originalsourceid><addsrcrecordid>eNp9kU-LFDEQxYMo7rj6BTxIwIuX1vzrpONtHGZVWHTAFbyFdKeyk7U7mU260b36yY07q4IHT1VQv_eqiofQU0peUkLUq0IIk7IhjDeEK8qa9h5aUcFrwwS9j1aES9EwKr-coEelXBFCmVLiITrhSnPWErVCP9b4k_WAL2DYx3C9APYp4-33IZQQL_G8B7yDfIDowrCMNuPdaGfAyd-OtvN-SsHhNykCDhHv7BwgzgV_C_Meb3JKX8HhD6nAa7zGZyGGqt2OMFUIr6Mdb0ooj9EDb8cCT-7qKfp8tr3YvGvOP759v1mfNwNncm609Y5LN9i2Nl2nFXNDfZArOVhPRS-U1M4TLnrS6t5pr2nvKQcQzDFQjp-iF0ffQ0710TKbKZQBxtFGSEsxrOuk5lorXtHn_6BXacn13mJ43UA6KTpdKXakhpxKyeDNIYfJ5htDifmVkDkmZGpC5jYh01bRszvrpZ_A_ZH8jqQC_AiUOoqXkP_u_o_tTw5Am7o</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3034086489</pqid></control><display><type>article</type><title>A Safe Technique for Excising the Perpendicular Plate of the Ethmoid Bone in Patients with Crooked Nose: A Finite Element Analysis</title><source>Springer Nature</source><creator>Sun, Yi-Dan ; Wu, Si-Qiao ; Wang, Zheng ; Zhao, Zhen-Min ; An, Yang</creator><creatorcontrib>Sun, Yi-Dan ; Wu, Si-Qiao ; Wang, Zheng ; Zhao, Zhen-Min ; An, Yang</creatorcontrib><description>Background Correction of the crooked nose, especially the perpendicular plate of the ethmoid bone, has the potential to cause skull base injury. At present, the safe and effective method for perpendicular plate resection has not been clearly defined through biomechanics. Method CT scan data of 48 patients with crooked nose and deviated nasal septum were divided into C-type, angular deformity-type, and S-type based on the morphology of the 3D model. Different types of finite element models of the nasal bony septum and skull base were established. The osteotomy depth, angle, and force mode of the PPE resection were simulated by assembling different working conditions for the models. The von Mises stress of the anterior cranial fossa was observed. Results When the osteotomy line length was 0.5 cm, the angle was at 30° to the Frankfurt plane, and 50 N·mm torque was applied, the von Mises stress of the skull base was minimal in the four models, showing 0.049 MPa (C-type), 0.082 MPa (S-type), 0.128 MPa (angular deformity-type), and 0.021 MPa (control model). The maximum von Mises stress values were found at the skull base when the osteotomy line was 1.5 cm, the angle was 50°, and the force was 10 N along the X-axis, showing 0.349 MPa (C-type), 0.698 MPa (S-type), 0.451 MPa (angular deformity-type), and 0.149 MPa (control model). Conclusion The use of smaller resection angle with the Frankfurt plane, conservative resection depth, and torsion force can better reduce the stress value at the skull base and reduce the risk of basicranial fracture. It is a safe and effective technique for perpendicular plate resection of the ethmoid bone in the correction of crooked nose. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .</description><identifier>ISSN: 0364-216X</identifier><identifier>EISSN: 1432-5241</identifier><identifier>DOI: 10.1007/s00266-023-03712-5</identifier><identifier>PMID: 37932507</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Medicine ; Medicine &amp; Public Health ; Nose ; Original Articles ; Otorhinolaryngology ; Plastic Surgery</subject><ispartof>Aesthetic plastic surgery, 2024-03, Vol.48 (6), p.1084-1093</ispartof><rights>Springer Science+Business Media, LLC, part of Springer Nature and International Society of Aesthetic Plastic Surgery 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><rights>2023. Springer Science+Business Media, LLC, part of Springer Nature and International Society of Aesthetic Plastic Surgery.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c326t-9afd36dca5afd88972dc036376caf14b4769df034b059bd9f91bf13ee42d2e7d3</cites><orcidid>0000-0003-3389-4832</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37932507$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sun, Yi-Dan</creatorcontrib><creatorcontrib>Wu, Si-Qiao</creatorcontrib><creatorcontrib>Wang, Zheng</creatorcontrib><creatorcontrib>Zhao, Zhen-Min</creatorcontrib><creatorcontrib>An, Yang</creatorcontrib><title>A Safe Technique for Excising the Perpendicular Plate of the Ethmoid Bone in Patients with Crooked Nose: A Finite Element Analysis</title><title>Aesthetic plastic surgery</title><addtitle>Aesth Plast Surg</addtitle><addtitle>Aesthetic Plast Surg</addtitle><description>Background Correction of the crooked nose, especially the perpendicular plate of the ethmoid bone, has the potential to cause skull base injury. At present, the safe and effective method for perpendicular plate resection has not been clearly defined through biomechanics. Method CT scan data of 48 patients with crooked nose and deviated nasal septum were divided into C-type, angular deformity-type, and S-type based on the morphology of the 3D model. Different types of finite element models of the nasal bony septum and skull base were established. The osteotomy depth, angle, and force mode of the PPE resection were simulated by assembling different working conditions for the models. The von Mises stress of the anterior cranial fossa was observed. Results When the osteotomy line length was 0.5 cm, the angle was at 30° to the Frankfurt plane, and 50 N·mm torque was applied, the von Mises stress of the skull base was minimal in the four models, showing 0.049 MPa (C-type), 0.082 MPa (S-type), 0.128 MPa (angular deformity-type), and 0.021 MPa (control model). The maximum von Mises stress values were found at the skull base when the osteotomy line was 1.5 cm, the angle was 50°, and the force was 10 N along the X-axis, showing 0.349 MPa (C-type), 0.698 MPa (S-type), 0.451 MPa (angular deformity-type), and 0.149 MPa (control model). Conclusion The use of smaller resection angle with the Frankfurt plane, conservative resection depth, and torsion force can better reduce the stress value at the skull base and reduce the risk of basicranial fracture. It is a safe and effective technique for perpendicular plate resection of the ethmoid bone in the correction of crooked nose. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .</description><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Nose</subject><subject>Original Articles</subject><subject>Otorhinolaryngology</subject><subject>Plastic Surgery</subject><issn>0364-216X</issn><issn>1432-5241</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kU-LFDEQxYMo7rj6BTxIwIuX1vzrpONtHGZVWHTAFbyFdKeyk7U7mU260b36yY07q4IHT1VQv_eqiofQU0peUkLUq0IIk7IhjDeEK8qa9h5aUcFrwwS9j1aES9EwKr-coEelXBFCmVLiITrhSnPWErVCP9b4k_WAL2DYx3C9APYp4-33IZQQL_G8B7yDfIDowrCMNuPdaGfAyd-OtvN-SsHhNykCDhHv7BwgzgV_C_Meb3JKX8HhD6nAa7zGZyGGqt2OMFUIr6Mdb0ooj9EDb8cCT-7qKfp8tr3YvGvOP759v1mfNwNncm609Y5LN9i2Nl2nFXNDfZArOVhPRS-U1M4TLnrS6t5pr2nvKQcQzDFQjp-iF0ffQ0710TKbKZQBxtFGSEsxrOuk5lorXtHn_6BXacn13mJ43UA6KTpdKXakhpxKyeDNIYfJ5htDifmVkDkmZGpC5jYh01bRszvrpZ_A_ZH8jqQC_AiUOoqXkP_u_o_tTw5Am7o</recordid><startdate>20240301</startdate><enddate>20240301</enddate><creator>Sun, Yi-Dan</creator><creator>Wu, Si-Qiao</creator><creator>Wang, Zheng</creator><creator>Zhao, Zhen-Min</creator><creator>An, Yang</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-3389-4832</orcidid></search><sort><creationdate>20240301</creationdate><title>A Safe Technique for Excising the Perpendicular Plate of the Ethmoid Bone in Patients with Crooked Nose: A Finite Element Analysis</title><author>Sun, Yi-Dan ; Wu, Si-Qiao ; Wang, Zheng ; Zhao, Zhen-Min ; An, Yang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c326t-9afd36dca5afd88972dc036376caf14b4769df034b059bd9f91bf13ee42d2e7d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Nose</topic><topic>Original Articles</topic><topic>Otorhinolaryngology</topic><topic>Plastic Surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sun, Yi-Dan</creatorcontrib><creatorcontrib>Wu, Si-Qiao</creatorcontrib><creatorcontrib>Wang, Zheng</creatorcontrib><creatorcontrib>Zhao, Zhen-Min</creatorcontrib><creatorcontrib>An, Yang</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>Aesthetic plastic surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sun, Yi-Dan</au><au>Wu, Si-Qiao</au><au>Wang, Zheng</au><au>Zhao, Zhen-Min</au><au>An, Yang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Safe Technique for Excising the Perpendicular Plate of the Ethmoid Bone in Patients with Crooked Nose: A Finite Element Analysis</atitle><jtitle>Aesthetic plastic surgery</jtitle><stitle>Aesth Plast Surg</stitle><addtitle>Aesthetic Plast Surg</addtitle><date>2024-03-01</date><risdate>2024</risdate><volume>48</volume><issue>6</issue><spage>1084</spage><epage>1093</epage><pages>1084-1093</pages><issn>0364-216X</issn><eissn>1432-5241</eissn><abstract>Background Correction of the crooked nose, especially the perpendicular plate of the ethmoid bone, has the potential to cause skull base injury. At present, the safe and effective method for perpendicular plate resection has not been clearly defined through biomechanics. Method CT scan data of 48 patients with crooked nose and deviated nasal septum were divided into C-type, angular deformity-type, and S-type based on the morphology of the 3D model. Different types of finite element models of the nasal bony septum and skull base were established. The osteotomy depth, angle, and force mode of the PPE resection were simulated by assembling different working conditions for the models. The von Mises stress of the anterior cranial fossa was observed. Results When the osteotomy line length was 0.5 cm, the angle was at 30° to the Frankfurt plane, and 50 N·mm torque was applied, the von Mises stress of the skull base was minimal in the four models, showing 0.049 MPa (C-type), 0.082 MPa (S-type), 0.128 MPa (angular deformity-type), and 0.021 MPa (control model). The maximum von Mises stress values were found at the skull base when the osteotomy line was 1.5 cm, the angle was 50°, and the force was 10 N along the X-axis, showing 0.349 MPa (C-type), 0.698 MPa (S-type), 0.451 MPa (angular deformity-type), and 0.149 MPa (control model). Conclusion The use of smaller resection angle with the Frankfurt plane, conservative resection depth, and torsion force can better reduce the stress value at the skull base and reduce the risk of basicranial fracture. It is a safe and effective technique for perpendicular plate resection of the ethmoid bone in the correction of crooked nose. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .</abstract><cop>New York</cop><pub>Springer US</pub><pmid>37932507</pmid><doi>10.1007/s00266-023-03712-5</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0003-3389-4832</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0364-216X
ispartof Aesthetic plastic surgery, 2024-03, Vol.48 (6), p.1084-1093
issn 0364-216X
1432-5241
language eng
recordid cdi_proquest_miscellaneous_2886939973
source Springer Nature
subjects Medicine
Medicine & Public Health
Nose
Original Articles
Otorhinolaryngology
Plastic Surgery
title A Safe Technique for Excising the Perpendicular Plate of the Ethmoid Bone in Patients with Crooked Nose: A Finite Element Analysis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T14%3A33%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Safe%20Technique%20for%20Excising%20the%20Perpendicular%20Plate%20of%20the%20Ethmoid%20Bone%20in%20Patients%20with%20Crooked%20Nose:%20A%20Finite%20Element%20Analysis&rft.jtitle=Aesthetic%20plastic%20surgery&rft.au=Sun,%20Yi-Dan&rft.date=2024-03-01&rft.volume=48&rft.issue=6&rft.spage=1084&rft.epage=1093&rft.pages=1084-1093&rft.issn=0364-216X&rft.eissn=1432-5241&rft_id=info:doi/10.1007/s00266-023-03712-5&rft_dat=%3Cproquest_cross%3E2886939973%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c326t-9afd36dca5afd88972dc036376caf14b4769df034b059bd9f91bf13ee42d2e7d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3034086489&rft_id=info:pmid/37932507&rfr_iscdi=true