Loading…

Stent Strut Dilation in Branch Pulmonary Artery Stenosis Following Stenting of Arterial Duct in Duct-dependent Pulmonary Circulation

To assess the feasibility and outcome of stent strut dilation after arterial duct stenting with associated branch pulmonary artery (BPA) stenosis. Stenting of arterial duct in infants with duct-dependent pulmonary circulation is technically challenging. The presence of BPA stenosis is a relative con...

Full description

Saved in:
Bibliographic Details
Published in:Pediatric cardiology 2023-11
Main Authors: Koneti, Nageswara Rao, Bakhru, Shweta, Dhulipudi, Bhargavi, Rajan, Saileela, Sreeram, Narayanswami
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To assess the feasibility and outcome of stent strut dilation after arterial duct stenting with associated branch pulmonary artery (BPA) stenosis. Stenting of arterial duct in infants with duct-dependent pulmonary circulation is technically challenging. The presence of BPA stenosis is a relative contraindication for stent implantation. Infants with duct-dependent pulmonary circulation and associated BPA stenosis were assessed either by transthoracic echocardiogram alone or additional computerized tomography angiogram when required. Following ductal stenting, the stent struts of the stenosed BPA were crossed with an additional 0.014″ coronary guide wire and dilated using coronary balloons (2.0 or 2.5 mm in diameter). Seventeen (12 male) patients were considered for the procedure. The median age and weight were 27 days (range 2-94) and 2.6 kg (range 2.2-5), respectively. Fourteen patients (82.4%) underwent stent strut dilation after arterial duct stenting. Struts to left pulmonary artery was opened in 9 (64.3%) and right pulmonary artery in 5 (35.7%). The mean systemic oxygen saturation increased from 66.23 ± 8.9% at baseline to 86 ± 2.2% immediately after the stent deployment and final saturations after stent strut dilation were 89.29 ± 4.3%. Angiographic pulmonary flow improved in all cases. Stent strut dilation could not be done in 3 patients due to unfavorable anatomy. One patient had acute stent thrombosis and died in the hospital. Two others died during follow-up, during an acute febrile illness and gastroenteritis. All survivors underwent cardiac surgery and were on regular follow-up. Strut dilation of BPA stenosis is feasible to augment pulmonary blood flow, following arterial duct stenting. This procedure may be useful in selected patients with BPA stenosis to have uniform growth of pulmonary arteries.
ISSN:0172-0643
1432-1971
DOI:10.1007/s00246-023-03319-2