A functional brace for treating Colles fractures; volunteer trial of a new design

Presently used Colles' fracture treatments have similar outcomes with significant complications. Previous studies of a dynamic functional fracture brace, achieving similar or better results had no significant complications. A novel brace design is described to achieve optimal patient outcomes....

Full description

Saved in:
Bibliographic Details
Published in:Clinical biomechanics (Bristol) 2024-02, Vol.112, p.106181-106181, Article 106181
Main Authors: Wardlaw, Douglas, Murdoch, Ann H.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c321t-7f2dab1c18c2be0744b88069bead1a58f7f093a86f863fff0cff6e38eecc85403
container_end_page 106181
container_issue
container_start_page 106181
container_title Clinical biomechanics (Bristol)
container_volume 112
creator Wardlaw, Douglas
Murdoch, Ann H.
description Presently used Colles' fracture treatments have similar outcomes with significant complications. Previous studies of a dynamic functional fracture brace, achieving similar or better results had no significant complications. A novel brace design is described to achieve optimal patient outcomes. Patient forearm measurements combined with data from a previously tested brace provided parameters for a brace formed using computer assisted design. Fracture swelling was simulated using a 40 ml (ml) plastic water filled bag placed over the dorsum of the lower radius. The interface pressure between the brace, skin and bag were measured on twelve human volunteers, four with forearm measurements to fit each of small, medium and large brace sizes. Measurements were taken at intervals reducing volume of fluid in the bag by 10 ml until empty, first wearing a brace, and then with a Colles plaster of Paris cast. The brace produced interface pressures over the lower radius in the range of 62.5–90 (mm Hg) and when the bag was completely empty the pressure range was 43–83 mmHg. The initial interface pressures in the Colles casts were in the range of 15–18 mm of Mercury (mm Hg) and when 10 mls were removed from the plastic bag the interface pressure dropped immediately to almost zero. The brace measurements show pressures higher than a Colles cast which compensate for reduction of simulated swelling. It is safe and is potentially the optimal design to achieve significantly improved patient outcomes. •Plaster of Paris interface pressures in pad one were consistent and all others inconsistent.•Plaster of Paris interface pressures are low and allow the facture to displace in some cases.•The brace interface pressures are consistent.•The brace interface pressures are at a level likely to prevent fracture displacement.•The brace is comfortable and had no complications in eighteen patients.
doi_str_mv 10.1016/j.clinbiomech.2024.106181
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2928243962</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0268003324000135</els_id><sourcerecordid>2928243962</sourcerecordid><originalsourceid>FETCH-LOGICAL-c321t-7f2dab1c18c2be0744b88069bead1a58f7f093a86f863fff0cff6e38eecc85403</originalsourceid><addsrcrecordid>eNqNkE1LxDAQhoMo7rr6FyTevHTNR7dN8bQUv2BBBD2HNJ2sWdpkTdoV_71duopHTwMzzzvDPAhdUTKnhGY3m7lurKusb0G_zxlh6dDPqKBHaEpFXiSU5fQYTQnLREII5xN0FuOGEJKyRX6KJlywXBCRTtHLEpve6c56pxpcBaUBGx9wF0B11q1x6ZsGIjbDpOsDxFu8803vOoA9ZIeQN1hhB5-4hmjX7hydGNVEuDjUGXq7v3stH5PV88NTuVwlmjPaJblhtaqopkKzCkieppUQJCsqUDVVC2FyQwquRGZExo0xRBuTARcAWotFSvgMXY97t8F_9BA72dqooWmUA99HyQomWMqLjA1oMaI6-BgDGLkNtlXhS1Ii90blRv4xKvdG5Wh0yF4ezvRVC_Vv8kfhAJQjAMOzOwtBRm3BaahtAN3J2tt_nPkGlAeN-g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2928243962</pqid></control><display><type>article</type><title>A functional brace for treating Colles fractures; volunteer trial of a new design</title><source>Elsevier</source><creator>Wardlaw, Douglas ; Murdoch, Ann H.</creator><creatorcontrib>Wardlaw, Douglas ; Murdoch, Ann H.</creatorcontrib><description>Presently used Colles' fracture treatments have similar outcomes with significant complications. Previous studies of a dynamic functional fracture brace, achieving similar or better results had no significant complications. A novel brace design is described to achieve optimal patient outcomes. Patient forearm measurements combined with data from a previously tested brace provided parameters for a brace formed using computer assisted design. Fracture swelling was simulated using a 40 ml (ml) plastic water filled bag placed over the dorsum of the lower radius. The interface pressure between the brace, skin and bag were measured on twelve human volunteers, four with forearm measurements to fit each of small, medium and large brace sizes. Measurements were taken at intervals reducing volume of fluid in the bag by 10 ml until empty, first wearing a brace, and then with a Colles plaster of Paris cast. The brace produced interface pressures over the lower radius in the range of 62.5–90 (mm Hg) and when the bag was completely empty the pressure range was 43–83 mmHg. The initial interface pressures in the Colles casts were in the range of 15–18 mm of Mercury (mm Hg) and when 10 mls were removed from the plastic bag the interface pressure dropped immediately to almost zero. The brace measurements show pressures higher than a Colles cast which compensate for reduction of simulated swelling. It is safe and is potentially the optimal design to achieve significantly improved patient outcomes. •Plaster of Paris interface pressures in pad one were consistent and all others inconsistent.•Plaster of Paris interface pressures are low and allow the facture to displace in some cases.•The brace interface pressures are consistent.•The brace interface pressures are at a level likely to prevent fracture displacement.•The brace is comfortable and had no complications in eighteen patients.</description><identifier>ISSN: 0268-0033</identifier><identifier>EISSN: 1879-1271</identifier><identifier>DOI: 10.1016/j.clinbiomech.2024.106181</identifier><identifier>PMID: 38278084</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Aberdeen fracture brace ; Casts, Surgical ; Closed reduction ; Colles' fracture ; Colles' Fracture - therapy ; Functional bracing ; Humans ; Immediate application ; Immediate mobilisation ; Radius ; Radius Fractures - therapy ; Three-point loading ; Volunteers</subject><ispartof>Clinical biomechanics (Bristol), 2024-02, Vol.112, p.106181-106181, Article 106181</ispartof><rights>2024 Elsevier Ltd</rights><rights>Copyright © 2024 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c321t-7f2dab1c18c2be0744b88069bead1a58f7f093a86f863fff0cff6e38eecc85403</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38278084$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wardlaw, Douglas</creatorcontrib><creatorcontrib>Murdoch, Ann H.</creatorcontrib><title>A functional brace for treating Colles fractures; volunteer trial of a new design</title><title>Clinical biomechanics (Bristol)</title><addtitle>Clin Biomech (Bristol, Avon)</addtitle><description>Presently used Colles' fracture treatments have similar outcomes with significant complications. Previous studies of a dynamic functional fracture brace, achieving similar or better results had no significant complications. A novel brace design is described to achieve optimal patient outcomes. Patient forearm measurements combined with data from a previously tested brace provided parameters for a brace formed using computer assisted design. Fracture swelling was simulated using a 40 ml (ml) plastic water filled bag placed over the dorsum of the lower radius. The interface pressure between the brace, skin and bag were measured on twelve human volunteers, four with forearm measurements to fit each of small, medium and large brace sizes. Measurements were taken at intervals reducing volume of fluid in the bag by 10 ml until empty, first wearing a brace, and then with a Colles plaster of Paris cast. The brace produced interface pressures over the lower radius in the range of 62.5–90 (mm Hg) and when the bag was completely empty the pressure range was 43–83 mmHg. The initial interface pressures in the Colles casts were in the range of 15–18 mm of Mercury (mm Hg) and when 10 mls were removed from the plastic bag the interface pressure dropped immediately to almost zero. The brace measurements show pressures higher than a Colles cast which compensate for reduction of simulated swelling. It is safe and is potentially the optimal design to achieve significantly improved patient outcomes. •Plaster of Paris interface pressures in pad one were consistent and all others inconsistent.•Plaster of Paris interface pressures are low and allow the facture to displace in some cases.•The brace interface pressures are consistent.•The brace interface pressures are at a level likely to prevent fracture displacement.•The brace is comfortable and had no complications in eighteen patients.</description><subject>Aberdeen fracture brace</subject><subject>Casts, Surgical</subject><subject>Closed reduction</subject><subject>Colles' fracture</subject><subject>Colles' Fracture - therapy</subject><subject>Functional bracing</subject><subject>Humans</subject><subject>Immediate application</subject><subject>Immediate mobilisation</subject><subject>Radius</subject><subject>Radius Fractures - therapy</subject><subject>Three-point loading</subject><subject>Volunteers</subject><issn>0268-0033</issn><issn>1879-1271</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqNkE1LxDAQhoMo7rr6FyTevHTNR7dN8bQUv2BBBD2HNJ2sWdpkTdoV_71duopHTwMzzzvDPAhdUTKnhGY3m7lurKusb0G_zxlh6dDPqKBHaEpFXiSU5fQYTQnLREII5xN0FuOGEJKyRX6KJlywXBCRTtHLEpve6c56pxpcBaUBGx9wF0B11q1x6ZsGIjbDpOsDxFu8803vOoA9ZIeQN1hhB5-4hmjX7hydGNVEuDjUGXq7v3stH5PV88NTuVwlmjPaJblhtaqopkKzCkieppUQJCsqUDVVC2FyQwquRGZExo0xRBuTARcAWotFSvgMXY97t8F_9BA72dqooWmUA99HyQomWMqLjA1oMaI6-BgDGLkNtlXhS1Ii90blRv4xKvdG5Wh0yF4ezvRVC_Vv8kfhAJQjAMOzOwtBRm3BaahtAN3J2tt_nPkGlAeN-g</recordid><startdate>202402</startdate><enddate>202402</enddate><creator>Wardlaw, Douglas</creator><creator>Murdoch, Ann H.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202402</creationdate><title>A functional brace for treating Colles fractures; volunteer trial of a new design</title><author>Wardlaw, Douglas ; Murdoch, Ann H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c321t-7f2dab1c18c2be0744b88069bead1a58f7f093a86f863fff0cff6e38eecc85403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Aberdeen fracture brace</topic><topic>Casts, Surgical</topic><topic>Closed reduction</topic><topic>Colles' fracture</topic><topic>Colles' Fracture - therapy</topic><topic>Functional bracing</topic><topic>Humans</topic><topic>Immediate application</topic><topic>Immediate mobilisation</topic><topic>Radius</topic><topic>Radius Fractures - therapy</topic><topic>Three-point loading</topic><topic>Volunteers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wardlaw, Douglas</creatorcontrib><creatorcontrib>Murdoch, Ann H.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical biomechanics (Bristol)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wardlaw, Douglas</au><au>Murdoch, Ann H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A functional brace for treating Colles fractures; volunteer trial of a new design</atitle><jtitle>Clinical biomechanics (Bristol)</jtitle><addtitle>Clin Biomech (Bristol, Avon)</addtitle><date>2024-02</date><risdate>2024</risdate><volume>112</volume><spage>106181</spage><epage>106181</epage><pages>106181-106181</pages><artnum>106181</artnum><issn>0268-0033</issn><eissn>1879-1271</eissn><abstract>Presently used Colles' fracture treatments have similar outcomes with significant complications. Previous studies of a dynamic functional fracture brace, achieving similar or better results had no significant complications. A novel brace design is described to achieve optimal patient outcomes. Patient forearm measurements combined with data from a previously tested brace provided parameters for a brace formed using computer assisted design. Fracture swelling was simulated using a 40 ml (ml) plastic water filled bag placed over the dorsum of the lower radius. The interface pressure between the brace, skin and bag were measured on twelve human volunteers, four with forearm measurements to fit each of small, medium and large brace sizes. Measurements were taken at intervals reducing volume of fluid in the bag by 10 ml until empty, first wearing a brace, and then with a Colles plaster of Paris cast. The brace produced interface pressures over the lower radius in the range of 62.5–90 (mm Hg) and when the bag was completely empty the pressure range was 43–83 mmHg. The initial interface pressures in the Colles casts were in the range of 15–18 mm of Mercury (mm Hg) and when 10 mls were removed from the plastic bag the interface pressure dropped immediately to almost zero. The brace measurements show pressures higher than a Colles cast which compensate for reduction of simulated swelling. It is safe and is potentially the optimal design to achieve significantly improved patient outcomes. •Plaster of Paris interface pressures in pad one were consistent and all others inconsistent.•Plaster of Paris interface pressures are low and allow the facture to displace in some cases.•The brace interface pressures are consistent.•The brace interface pressures are at a level likely to prevent fracture displacement.•The brace is comfortable and had no complications in eighteen patients.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>38278084</pmid><doi>10.1016/j.clinbiomech.2024.106181</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0268-0033
ispartof Clinical biomechanics (Bristol), 2024-02, Vol.112, p.106181-106181, Article 106181
issn 0268-0033
1879-1271
language eng
recordid cdi_proquest_miscellaneous_2928243962
source Elsevier
subjects Aberdeen fracture brace
Casts, Surgical
Closed reduction
Colles' fracture
Colles' Fracture - therapy
Functional bracing
Humans
Immediate application
Immediate mobilisation
Radius
Radius Fractures - therapy
Three-point loading
Volunteers
title A functional brace for treating Colles fractures; volunteer trial of a new design
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T12%3A01%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20functional%20brace%20for%20treating%20Colles%20fractures;%20volunteer%20trial%20of%20a%20new%20design&rft.jtitle=Clinical%20biomechanics%20(Bristol)&rft.au=Wardlaw,%20Douglas&rft.date=2024-02&rft.volume=112&rft.spage=106181&rft.epage=106181&rft.pages=106181-106181&rft.artnum=106181&rft.issn=0268-0033&rft.eissn=1879-1271&rft_id=info:doi/10.1016/j.clinbiomech.2024.106181&rft_dat=%3Cproquest_cross%3E2928243962%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c321t-7f2dab1c18c2be0744b88069bead1a58f7f093a86f863fff0cff6e38eecc85403%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2928243962&rft_id=info:pmid/38278084&rfr_iscdi=true