"Fontan Conduit Stent-Angioplasty and Progression of Fontan-Associated Liver Disease"

Patients with Fontan circulation insidiously develop congestive hepatopathy related to chronically reduced cardiac output and central venous hypertension, also known as Fontan-associated liver disease (FALD). Fontan pathway obstruction is increasingly detected and may accelerate FALD. The impact of...

Full description

Saved in:
Bibliographic Details
Published in:Pediatric cardiology 2024-03
Main Authors: Kavin, Umakanthan, Shahrier, Aniqa, Bandisode, Varsha M, Chowdhury, Shahryar M, Rhodes, John F, Gaydos, Stephanie S
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Patients with Fontan circulation insidiously develop congestive hepatopathy related to chronically reduced cardiac output and central venous hypertension, also known as Fontan-associated liver disease (FALD). Fontan pathway obstruction is increasingly detected and may accelerate FALD. The impact of conduit stent angioplasty on FALD is unknown. Retrospective, single-center review of patients with Fontan circulation who underwent conduit stent angioplasty at cardiac catheterization over 5-year period. Demographics and cardiac histories were reviewed. Labs, liver ultrasound elastography, echocardiogram, hemodynamic and angiographic data at catheterization were recorded pre- and post-stent angioplasty. Primary outcome was change in hepatic function via MELD-XI scores and liver stiffness (kPa), with secondary outcomes of ventricular function, BNP, and repeat catheterization hemodynamics. 33 patients underwent Fontan conduit stent angioplasty, 19.3 ± 7.0 years from Fontan operation. Original conduit diameter was 19.1 ± 1.9 mm. Prior to angioplasty, conduit size was reduced to a cross-sectional area 132 (91, 173) mm and increased to 314 (255, 363) mm post-stent. Subjects' baseline median MELD-XI of 11 (9, 12) increased to 12 (9, 13) at 19 ± 15.5 months post-angioplasty (n = 22, p = 0.053). There was no significant change in liver stiffness at 12.1 ± 8.9 months post-angioplasty (n = 15, p = 0.13). Median total bilirubin significantly increased (1.4 [0.9, 1.8]), from baseline 1.1 [0.7, 1.5], p = 0.04), as did median BNP (41 [0, 148] from baseline 34 [15, 79]; p = 0.02). There were no significant changes in ventricular function or repeat invasive hemodynamics (n = 8 subjects). Mid-term follow-up of Fontan subjects post-conduit stent angioplasty did not show improvements in non-invasive markers of FALD.
ISSN:0172-0643
1432-1971
DOI:10.1007/s00246-024-03426-8