Loading…
Revision Total Hip Arthroplasty Performed with a Contemporary Alumina-on-Alumina Bearing Surface; Minimum 5-Year Follow-Up Study
Limitation in liner and head options available to the surgeon may be the most practical disadvantage of alumina-on-alumina total hip arthroplasty (THA). This may be more problematic in the revision THA. We evaluated the results of 57 revision THAs (average, 46.2 years old) performed with a contempor...
Saved in:
Published in: | Key engineering materials 2006-01, Vol.309-311, p.1353-1356 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Limitation in liner and head options available to the surgeon may be the most practical
disadvantage of alumina-on-alumina total hip arthroplasty (THA). This may be more problematic in the revision THA. We evaluated the results of 57 revision THAs (average, 46.2 years old) performed with a contemporary alumina-on-alumina bearing surface after a 5-year minimum follow-up (average, 67 months; range, 60-85 months). A third generation alumina-on-alumina bearing (BIOLOX® forte, CeramTec AG) and a cementless PLASMACUP®-BiCONTACT® hip
revision system (AESCULAP AG & Co.) had been used in all patients. Alumina bearing was chosen for a relatively young active patient in whom an acetabular bone defect was not severe and an extremely long neck of artificial head was not required for the restoration of hip joint mechanics. The average Harris hip score improved from 65.0 points to 88.9 points. No implant loosened, no stem or cup was re-revised, and no additional reoperations were required. Ceramic wear was
undetectable in 14 hips where differentiation of the femoral head from the cup was possible on radiographs and no osteolysis was observed. During the follow-up period, no hip demonstrated signs of infection or ceramic failure. Short-term results of revision THAs performed with analumina-on-alumina bearing are encouraging. We believe that physiological age and activity level of a patient, severity of acetabular bone loss, and availability of alumina head and liner options
required for the restoration of proper limb length and joint stability should be considered to choose this alumina bearing surface during the revision THA. |
---|---|
ISSN: | 1013-9826 1662-9795 1662-9795 |
DOI: | 10.4028/www.scientific.net/KEM.309-311.1353 |