Maximum smoke temperature under the ceiling in a tunnel fire was studied experimentally and numerically. Full-scale burning tests in two vehicular tunnels of length 3.27 and 1.032 km with and without operating the longitudinal ventilation system were carried out. Smoke temperatures at selected posit...

Full description

Saved in:
Bibliographic Details
Published in:Tunnelling and underground space technology 2006-11, Vol.21 (6), p.650-655
Main Authors: Hu, L.H., Huo, R., Peng, W., Chow, W.K., Yang, R.X.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Maximum smoke temperature under the ceiling in a tunnel fire was studied experimentally and numerically. Full-scale burning tests in two vehicular tunnels of length 3.27 and 1.032 km with and without operating the longitudinal ventilation system were carried out. Smoke temperatures at selected positions under the ceiling were measured under different longitudinal ventilation velocities. Two different pool fires of 1.6 and 3 MW were set up. Computational Fluid Dynamics (CFD) simulations with Fire Dynamics Simulator (FDS) version 3.10 were carried out on those scenarios. CFD predicted smoke temperatures were firstly verified by comparing with the measured values at those selected positions, and then compared with the calculated values using the empirical equation due to Kurioka et al. Fairly good agreement was achieved, though the slope of the tunnel was not considered in this empirical equation.
ISSN:0886-7798
1878-4364
DOI:10.1016/j.tust.2005.10.003