Loading…

Activated sludge monitoring of a wastewater treatment plant using image analysis and partial least squares regression

The biomass present in a wastewater treatment plant was surveyed and their morphological properties related with operating parameters such as the total suspended solids (TSS) and sludge volume index (SVI). For that purpose image analysis was used to provide the morphological data subsequently treate...

Full description

Saved in:
Bibliographic Details
Published in:Analytica chimica acta 2005-07, Vol.544 (1), p.246-253
Main Authors: Amaral, A.L., Ferreira, E.C.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The biomass present in a wastewater treatment plant was surveyed and their morphological properties related with operating parameters such as the total suspended solids (TSS) and sludge volume index (SVI). For that purpose image analysis was used to provide the morphological data subsequently treated by partial least squares regression (PLS) multivariable statistical technique. The results denoted the existence of a severe bulking problem of non-zoogleal nature and the PLS analysis revealed a strong relationship between the TSS and the total aggregates area as well as a close correlation between the filamentous bacteria per suspended solids ratio and the SVI.
ISSN:0003-2670
1873-4324
DOI:10.1016/j.aca.2004.12.061