Loading…

Analysis of EIS characteristics of CO2 corrosion of well tube steels with corrosion scales

The electrochemical impedance spectroscopy (EIS) was used to study the characteristics of CO2 corrosion of N80 and 4Cr steels with corrosion scales. The results indicated that CO2 corrosion scale on tube steel could prevent the rate of mass transfer remarkably, corrosion rate was controlled by ions...

Full description

Saved in:
Bibliographic Details
Published in:Applied surface science 2006-08, Vol.252 (20), p.7578-7584
Main Authors: BAI, Z. Q, CHEN, C. F, LU, M. X, LI, J. B
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c242t-76a7595e14f958fbbe86e73afdfcd6039d99113f9555a82e62eaa4832ede35173
cites cdi_FETCH-LOGICAL-c242t-76a7595e14f958fbbe86e73afdfcd6039d99113f9555a82e62eaa4832ede35173
container_end_page 7584
container_issue 20
container_start_page 7578
container_title Applied surface science
container_volume 252
creator BAI, Z. Q
CHEN, C. F
LU, M. X
LI, J. B
description The electrochemical impedance spectroscopy (EIS) was used to study the characteristics of CO2 corrosion of N80 and 4Cr steels with corrosion scales. The results indicated that CO2 corrosion scale on tube steel could prevent the rate of mass transfer remarkably, corrosion rate was controlled by ions diffusion in corrosion scale, which led to finite length diffusion impedance occurred in electrochemical impedance spectra. Additionally, pitting of N80 steel could lead to additional capacitive reactance in impedance spectrum. The ion diffusion coefficient in corrosion scale and porosity of corrosion scale could be calculated by Warburg impedance coefficient, the results shown that the value of H+ diffusion coefficient in N80 and 4Cr corrosion scale is (3.46 and 1.76)X10-10m2s-1, respectively. The protective ability of 4Cr corrosion scale was better than that of N80 corrosion scale.
doi_str_mv 10.1016/j.apsusc.2005.09.011
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_29531774</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29531774</sourcerecordid><originalsourceid>FETCH-LOGICAL-c242t-76a7595e14f958fbbe86e73afdfcd6039d99113f9555a82e62eaa4832ede35173</originalsourceid><addsrcrecordid>eNpNUMtKw0AUHUTBWv0DF9noLnEemUxmWUrVgtCFunEzTCd36JQ0qXMTSv_exBZ0deG8OPcQcs9oxigrnraZ3WOPLuOUyozqjDJ2QSasVCKVsswvyWSQ6TQXgl-TG8QtpYwP7IR8zRpbHzFg0vpksXxP3MZG6zqIAbvgfuH5iieujbHF0DYjcIC6Trp-DQl2ADUmh9Bt_knQ2Rrwllx5WyPcne-UfD4vPuav6dvqZTmfvaWO57xLVWGV1BJY7rUs_XoNZQFKWF95VxVU6EprxsRASmlLDgUHa_NScKhASKbElDyecvex_e4BO7ML6IaKtoG2R8O1FEypfBDmJ6EbemIEb_Yx7Gw8GkbNOKTZmtOQZhzSUG2GIQfbwznfjo_5aBsX8M9b0kIxVoof_at2UA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29531774</pqid></control><display><type>article</type><title>Analysis of EIS characteristics of CO2 corrosion of well tube steels with corrosion scales</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>BAI, Z. Q ; CHEN, C. F ; LU, M. X ; LI, J. B</creator><creatorcontrib>BAI, Z. Q ; CHEN, C. F ; LU, M. X ; LI, J. B</creatorcontrib><description>The electrochemical impedance spectroscopy (EIS) was used to study the characteristics of CO2 corrosion of N80 and 4Cr steels with corrosion scales. The results indicated that CO2 corrosion scale on tube steel could prevent the rate of mass transfer remarkably, corrosion rate was controlled by ions diffusion in corrosion scale, which led to finite length diffusion impedance occurred in electrochemical impedance spectra. Additionally, pitting of N80 steel could lead to additional capacitive reactance in impedance spectrum. The ion diffusion coefficient in corrosion scale and porosity of corrosion scale could be calculated by Warburg impedance coefficient, the results shown that the value of H+ diffusion coefficient in N80 and 4Cr corrosion scale is (3.46 and 1.76)X10-10m2s-1, respectively. The protective ability of 4Cr corrosion scale was better than that of N80 corrosion scale.</description><identifier>ISSN: 0169-4332</identifier><identifier>EISSN: 1873-5584</identifier><identifier>DOI: 10.1016/j.apsusc.2005.09.011</identifier><language>eng</language><publisher>Amsterdam: Elsevier Science</publisher><subject>Applied sciences ; Corrosion ; Corrosion mechanisms ; Exact sciences and technology ; Metals. Metallurgy</subject><ispartof>Applied surface science, 2006-08, Vol.252 (20), p.7578-7584</ispartof><rights>2007 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c242t-76a7595e14f958fbbe86e73afdfcd6039d99113f9555a82e62eaa4832ede35173</citedby><cites>FETCH-LOGICAL-c242t-76a7595e14f958fbbe86e73afdfcd6039d99113f9555a82e62eaa4832ede35173</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=18067118$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>BAI, Z. Q</creatorcontrib><creatorcontrib>CHEN, C. F</creatorcontrib><creatorcontrib>LU, M. X</creatorcontrib><creatorcontrib>LI, J. B</creatorcontrib><title>Analysis of EIS characteristics of CO2 corrosion of well tube steels with corrosion scales</title><title>Applied surface science</title><description>The electrochemical impedance spectroscopy (EIS) was used to study the characteristics of CO2 corrosion of N80 and 4Cr steels with corrosion scales. The results indicated that CO2 corrosion scale on tube steel could prevent the rate of mass transfer remarkably, corrosion rate was controlled by ions diffusion in corrosion scale, which led to finite length diffusion impedance occurred in electrochemical impedance spectra. Additionally, pitting of N80 steel could lead to additional capacitive reactance in impedance spectrum. The ion diffusion coefficient in corrosion scale and porosity of corrosion scale could be calculated by Warburg impedance coefficient, the results shown that the value of H+ diffusion coefficient in N80 and 4Cr corrosion scale is (3.46 and 1.76)X10-10m2s-1, respectively. The protective ability of 4Cr corrosion scale was better than that of N80 corrosion scale.</description><subject>Applied sciences</subject><subject>Corrosion</subject><subject>Corrosion mechanisms</subject><subject>Exact sciences and technology</subject><subject>Metals. Metallurgy</subject><issn>0169-4332</issn><issn>1873-5584</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNpNUMtKw0AUHUTBWv0DF9noLnEemUxmWUrVgtCFunEzTCd36JQ0qXMTSv_exBZ0deG8OPcQcs9oxigrnraZ3WOPLuOUyozqjDJ2QSasVCKVsswvyWSQ6TQXgl-TG8QtpYwP7IR8zRpbHzFg0vpksXxP3MZG6zqIAbvgfuH5iieujbHF0DYjcIC6Trp-DQl2ADUmh9Bt_knQ2Rrwllx5WyPcne-UfD4vPuav6dvqZTmfvaWO57xLVWGV1BJY7rUs_XoNZQFKWF95VxVU6EprxsRASmlLDgUHa_NScKhASKbElDyecvex_e4BO7ML6IaKtoG2R8O1FEypfBDmJ6EbemIEb_Yx7Gw8GkbNOKTZmtOQZhzSUG2GIQfbwznfjo_5aBsX8M9b0kIxVoof_at2UA</recordid><startdate>20060815</startdate><enddate>20060815</enddate><creator>BAI, Z. Q</creator><creator>CHEN, C. F</creator><creator>LU, M. X</creator><creator>LI, J. B</creator><general>Elsevier Science</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SE</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20060815</creationdate><title>Analysis of EIS characteristics of CO2 corrosion of well tube steels with corrosion scales</title><author>BAI, Z. Q ; CHEN, C. F ; LU, M. X ; LI, J. B</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c242t-76a7595e14f958fbbe86e73afdfcd6039d99113f9555a82e62eaa4832ede35173</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Applied sciences</topic><topic>Corrosion</topic><topic>Corrosion mechanisms</topic><topic>Exact sciences and technology</topic><topic>Metals. Metallurgy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>BAI, Z. Q</creatorcontrib><creatorcontrib>CHEN, C. F</creatorcontrib><creatorcontrib>LU, M. X</creatorcontrib><creatorcontrib>LI, J. B</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Corrosion Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Applied surface science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>BAI, Z. Q</au><au>CHEN, C. F</au><au>LU, M. X</au><au>LI, J. B</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of EIS characteristics of CO2 corrosion of well tube steels with corrosion scales</atitle><jtitle>Applied surface science</jtitle><date>2006-08-15</date><risdate>2006</risdate><volume>252</volume><issue>20</issue><spage>7578</spage><epage>7584</epage><pages>7578-7584</pages><issn>0169-4332</issn><eissn>1873-5584</eissn><abstract>The electrochemical impedance spectroscopy (EIS) was used to study the characteristics of CO2 corrosion of N80 and 4Cr steels with corrosion scales. The results indicated that CO2 corrosion scale on tube steel could prevent the rate of mass transfer remarkably, corrosion rate was controlled by ions diffusion in corrosion scale, which led to finite length diffusion impedance occurred in electrochemical impedance spectra. Additionally, pitting of N80 steel could lead to additional capacitive reactance in impedance spectrum. The ion diffusion coefficient in corrosion scale and porosity of corrosion scale could be calculated by Warburg impedance coefficient, the results shown that the value of H+ diffusion coefficient in N80 and 4Cr corrosion scale is (3.46 and 1.76)X10-10m2s-1, respectively. The protective ability of 4Cr corrosion scale was better than that of N80 corrosion scale.</abstract><cop>Amsterdam</cop><pub>Elsevier Science</pub><doi>10.1016/j.apsusc.2005.09.011</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0169-4332
ispartof Applied surface science, 2006-08, Vol.252 (20), p.7578-7584
issn 0169-4332
1873-5584
language eng
recordid cdi_proquest_miscellaneous_29531774
source ScienceDirect Freedom Collection 2022-2024
subjects Applied sciences
Corrosion
Corrosion mechanisms
Exact sciences and technology
Metals. Metallurgy
title Analysis of EIS characteristics of CO2 corrosion of well tube steels with corrosion scales
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T11%3A37%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20EIS%20characteristics%20of%20CO2%20corrosion%20of%20well%20tube%20steels%20with%20corrosion%20scales&rft.jtitle=Applied%20surface%20science&rft.au=BAI,%20Z.%20Q&rft.date=2006-08-15&rft.volume=252&rft.issue=20&rft.spage=7578&rft.epage=7584&rft.pages=7578-7584&rft.issn=0169-4332&rft.eissn=1873-5584&rft_id=info:doi/10.1016/j.apsusc.2005.09.011&rft_dat=%3Cproquest_cross%3E29531774%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c242t-76a7595e14f958fbbe86e73afdfcd6039d99113f9555a82e62eaa4832ede35173%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=29531774&rft_id=info:pmid/&rfr_iscdi=true