Loading…
The OdonAssist inflatable device for assisted vaginal birth—the ASSIST II study (United Kingdom)
Decreasing rates of assisted vaginal birth have been paralleled with increasing rates of cesarean deliveries over the last 40 years. The OdonAssist is a novel device for assisted vaginal birth. Iterative changes to clinical parameters, device design, and technique have been made to improve device ef...
Saved in:
Published in: | American journal of obstetrics and gynecology 2024-03, Vol.230 (3), p.S932-S946.e3 |
---|---|
Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Decreasing rates of assisted vaginal birth have been paralleled with increasing rates of cesarean deliveries over the last 40 years. The OdonAssist is a novel device for assisted vaginal birth. Iterative changes to clinical parameters, device design, and technique have been made to improve device efficacy and usability.
This study aimed to determine if the feasibility, safety, and efficacy of the OdonAssist device were sufficient to justify conducting a future randomized controlled trial.
An open-label nonrandomized study of 104 participants having a clinically indicated assisted vaginal birth using the OdonAssist was undertaken at Southmead Hospital, Bristol, United Kingdom. Data were also collected from participants who consented to participate in the study but for whom trained OdonAssist operators were not available, providing a nested cohort. The primary clinical outcome was the proportion of births successfully expedited with the OdonAssist. Secondary outcomes included clinical, patient-reported, operator-reported, device and health care utilization. Neonatal outcome data were reviewed at day 28, and maternal outcomes were investigated up to day 90. Given that the number of successful OdonAssist births was ≥61 out of 104, the hypothesis of a poor rate of 50% was rejected in favor of a good rate of ≥65%.
Between August 2019 and June 2021, 941 (64%) of the 1471 approached, eligible participants consented to participate. Of these, 104 received the OdonAssist intervention. Birth was assisted in all cephalic vertex fetal positions, at all stations ≥1 cm below the ischial spines (with or without regional analgesia). The OdonAssist was effective in 69 of the 104 (66%) cases, consistent with the hypothesis of a good efficacy rate. There were no serious device-related maternal or neonatal adverse reactions, and there were no serious adverse device effects. Only 4% of neonatal soft tissue bruising in the successful OdonAssist group was considered device-related, as opposed to 20% and 23% in the unsuccessful OdonAssist group and the nested cohort, respectively. Participants reported high birth perception scores. All practitioners found the device use to be straightforward.
Recruitment to an interventional study of a new device for assisted vaginal birth is feasible; 64% of eligible participants were willing to participate. The success rate of the OdonAssist was comparable to that of the Kiwi OmniCup when introduced in the same unit in 2002, meeting the threshold |
---|---|
ISSN: | 0002-9378 1097-6868 1097-6868 |
DOI: | 10.1016/j.ajog.2023.05.018 |