Loading…

Longitudinal CT-based finite element analyses provide objective fracture healing measures in an ovine tibia model

Measuring the healing status of a bone fracture is important to determine the clinical care a patient receives. Implantable devices can directly and continuously assess the healing status of fracture fixation constructs, while subject-specific virtual biomechanical tests can noninvasively determine...

Full description

Saved in:
Bibliographic Details
Published in:Journal of orthopaedic research 2024-08, Vol.42 (8), p.1762-1770
Main Authors: Hetreau, Carla, Mischler, Dominic, Schlatter, Jérôme, Valenti, Alessia, Ernst, Manuela, Varga, Peter, Schwarzenberg, Peter
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c245t-a2fc83de438bc985815a75e54c52aaafb9fb70d3cc678c06ee2c5229a24335ee3
container_end_page 1770
container_issue 8
container_start_page 1762
container_title Journal of orthopaedic research
container_volume 42
creator Hetreau, Carla
Mischler, Dominic
Schlatter, Jérôme
Valenti, Alessia
Ernst, Manuela
Varga, Peter
Schwarzenberg, Peter
description Measuring the healing status of a bone fracture is important to determine the clinical care a patient receives. Implantable devices can directly and continuously assess the healing status of fracture fixation constructs, while subject-specific virtual biomechanical tests can noninvasively determine callus structural integrity at single time points. Despite their potential for objectification, both methods are not yet integrated into clinical practice with further evidence of their benefits required. This study correlated continuous data from an implantable sensor assessing healing status through implant load monitoring with computer tomography (CT) based longitudinal finite element (FE) simulations in a large animal model. Eight sheep were part of a previous preclinical study utilizing a tibial osteotomy model and equipped with such a sensor. Sensor signal was collected over several months, and CT scans were acquired at six interim time points. For each scan, two FE analyses were performed: a virtual torsional rigidity test of the bone and a model of the bone-implant construct with the sensor. The longitudinal simulation results were compared to the sensor data at corresponding time points and a cohort-specific empirical healing rule was employed. Healing status predicted by both in silico simulations correlated significantly with the sensor data at corresponding time points and correctly identified a delayed and a nonunion in the cohort. The methodology is readily translatable with the potential to be applied to further preclinical or clinical cohorts to find generalizable healing criteria. Virtual mechanical tests can objectively measure fracture healing progressing using longitudinal CT scans.
doi_str_mv 10.1002/jor.25838
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2957168925</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2957168925</sourcerecordid><originalsourceid>FETCH-LOGICAL-c245t-a2fc83de438bc985815a75e54c52aaafb9fb70d3cc678c06ee2c5229a24335ee3</originalsourceid><addsrcrecordid>eNo9kMtOwzAQRS0EoqWw4AeQl7BIcew4cZao4iVVYlMkdtHEmRRXidPaTqX-PYYCq9HVnLkaHUKuUzZPGeP3m8HNuVRCnZBpKmWWSF58nJIpK0SeMJ7nE3Lh_YYxVqRcnZOJUJkSMU7JbjnYtQljYyx0dLFKavDY0NZYE5Bihz3aQCEuDx493bphbxqkQ71BHcweaetAh9Eh_UTojF3THsHH7Kmx8Y5G3iINpjZA-6HB7pKctdB5vPqdM_L-9LhavCTLt-fXxcMy0TyTIQHeaiUazISqdamkSiUUEmWmJQeAti7bumCN0DovlGY5Io8bXgLPhJCIYkZuj73x592IPlS98Rq7DiwOo694KYs0VyWXEb07otoN3jtsq60zPbhDlbLq23AVDVc_hiN781s71j02_-SfUvEFInp4yQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2957168925</pqid></control><display><type>article</type><title>Longitudinal CT-based finite element analyses provide objective fracture healing measures in an ovine tibia model</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Hetreau, Carla ; Mischler, Dominic ; Schlatter, Jérôme ; Valenti, Alessia ; Ernst, Manuela ; Varga, Peter ; Schwarzenberg, Peter</creator><creatorcontrib>Hetreau, Carla ; Mischler, Dominic ; Schlatter, Jérôme ; Valenti, Alessia ; Ernst, Manuela ; Varga, Peter ; Schwarzenberg, Peter</creatorcontrib><description>Measuring the healing status of a bone fracture is important to determine the clinical care a patient receives. Implantable devices can directly and continuously assess the healing status of fracture fixation constructs, while subject-specific virtual biomechanical tests can noninvasively determine callus structural integrity at single time points. Despite their potential for objectification, both methods are not yet integrated into clinical practice with further evidence of their benefits required. This study correlated continuous data from an implantable sensor assessing healing status through implant load monitoring with computer tomography (CT) based longitudinal finite element (FE) simulations in a large animal model. Eight sheep were part of a previous preclinical study utilizing a tibial osteotomy model and equipped with such a sensor. Sensor signal was collected over several months, and CT scans were acquired at six interim time points. For each scan, two FE analyses were performed: a virtual torsional rigidity test of the bone and a model of the bone-implant construct with the sensor. The longitudinal simulation results were compared to the sensor data at corresponding time points and a cohort-specific empirical healing rule was employed. Healing status predicted by both in silico simulations correlated significantly with the sensor data at corresponding time points and correctly identified a delayed and a nonunion in the cohort. The methodology is readily translatable with the potential to be applied to further preclinical or clinical cohorts to find generalizable healing criteria. Virtual mechanical tests can objectively measure fracture healing progressing using longitudinal CT scans.</description><identifier>ISSN: 0736-0266</identifier><identifier>ISSN: 1554-527X</identifier><identifier>EISSN: 1554-527X</identifier><identifier>DOI: 10.1002/jor.25838</identifier><identifier>PMID: 38483000</identifier><language>eng</language><publisher>United States</publisher><subject>Animals ; Female ; Finite Element Analysis ; Fracture Healing ; Sheep ; Tibia - diagnostic imaging ; Tibial Fractures - diagnostic imaging ; Tibial Fractures - physiopathology ; Tibial Fractures - surgery ; Tomography, X-Ray Computed</subject><ispartof>Journal of orthopaedic research, 2024-08, Vol.42 (8), p.1762-1770</ispartof><rights>2024 Orthopaedic Research Society.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c245t-a2fc83de438bc985815a75e54c52aaafb9fb70d3cc678c06ee2c5229a24335ee3</cites><orcidid>0000-0002-8747-6786 ; 0000-0003-2738-6436</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38483000$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hetreau, Carla</creatorcontrib><creatorcontrib>Mischler, Dominic</creatorcontrib><creatorcontrib>Schlatter, Jérôme</creatorcontrib><creatorcontrib>Valenti, Alessia</creatorcontrib><creatorcontrib>Ernst, Manuela</creatorcontrib><creatorcontrib>Varga, Peter</creatorcontrib><creatorcontrib>Schwarzenberg, Peter</creatorcontrib><title>Longitudinal CT-based finite element analyses provide objective fracture healing measures in an ovine tibia model</title><title>Journal of orthopaedic research</title><addtitle>J Orthop Res</addtitle><description>Measuring the healing status of a bone fracture is important to determine the clinical care a patient receives. Implantable devices can directly and continuously assess the healing status of fracture fixation constructs, while subject-specific virtual biomechanical tests can noninvasively determine callus structural integrity at single time points. Despite their potential for objectification, both methods are not yet integrated into clinical practice with further evidence of their benefits required. This study correlated continuous data from an implantable sensor assessing healing status through implant load monitoring with computer tomography (CT) based longitudinal finite element (FE) simulations in a large animal model. Eight sheep were part of a previous preclinical study utilizing a tibial osteotomy model and equipped with such a sensor. Sensor signal was collected over several months, and CT scans were acquired at six interim time points. For each scan, two FE analyses were performed: a virtual torsional rigidity test of the bone and a model of the bone-implant construct with the sensor. The longitudinal simulation results were compared to the sensor data at corresponding time points and a cohort-specific empirical healing rule was employed. Healing status predicted by both in silico simulations correlated significantly with the sensor data at corresponding time points and correctly identified a delayed and a nonunion in the cohort. The methodology is readily translatable with the potential to be applied to further preclinical or clinical cohorts to find generalizable healing criteria. Virtual mechanical tests can objectively measure fracture healing progressing using longitudinal CT scans.</description><subject>Animals</subject><subject>Female</subject><subject>Finite Element Analysis</subject><subject>Fracture Healing</subject><subject>Sheep</subject><subject>Tibia - diagnostic imaging</subject><subject>Tibial Fractures - diagnostic imaging</subject><subject>Tibial Fractures - physiopathology</subject><subject>Tibial Fractures - surgery</subject><subject>Tomography, X-Ray Computed</subject><issn>0736-0266</issn><issn>1554-527X</issn><issn>1554-527X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNo9kMtOwzAQRS0EoqWw4AeQl7BIcew4cZao4iVVYlMkdtHEmRRXidPaTqX-PYYCq9HVnLkaHUKuUzZPGeP3m8HNuVRCnZBpKmWWSF58nJIpK0SeMJ7nE3Lh_YYxVqRcnZOJUJkSMU7JbjnYtQljYyx0dLFKavDY0NZYE5Bihz3aQCEuDx493bphbxqkQ71BHcweaetAh9Eh_UTojF3THsHH7Kmx8Y5G3iINpjZA-6HB7pKctdB5vPqdM_L-9LhavCTLt-fXxcMy0TyTIQHeaiUazISqdamkSiUUEmWmJQeAti7bumCN0DovlGY5Io8bXgLPhJCIYkZuj73x592IPlS98Rq7DiwOo694KYs0VyWXEb07otoN3jtsq60zPbhDlbLq23AVDVc_hiN781s71j02_-SfUvEFInp4yQ</recordid><startdate>20240801</startdate><enddate>20240801</enddate><creator>Hetreau, Carla</creator><creator>Mischler, Dominic</creator><creator>Schlatter, Jérôme</creator><creator>Valenti, Alessia</creator><creator>Ernst, Manuela</creator><creator>Varga, Peter</creator><creator>Schwarzenberg, Peter</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-8747-6786</orcidid><orcidid>https://orcid.org/0000-0003-2738-6436</orcidid></search><sort><creationdate>20240801</creationdate><title>Longitudinal CT-based finite element analyses provide objective fracture healing measures in an ovine tibia model</title><author>Hetreau, Carla ; Mischler, Dominic ; Schlatter, Jérôme ; Valenti, Alessia ; Ernst, Manuela ; Varga, Peter ; Schwarzenberg, Peter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c245t-a2fc83de438bc985815a75e54c52aaafb9fb70d3cc678c06ee2c5229a24335ee3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Animals</topic><topic>Female</topic><topic>Finite Element Analysis</topic><topic>Fracture Healing</topic><topic>Sheep</topic><topic>Tibia - diagnostic imaging</topic><topic>Tibial Fractures - diagnostic imaging</topic><topic>Tibial Fractures - physiopathology</topic><topic>Tibial Fractures - surgery</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hetreau, Carla</creatorcontrib><creatorcontrib>Mischler, Dominic</creatorcontrib><creatorcontrib>Schlatter, Jérôme</creatorcontrib><creatorcontrib>Valenti, Alessia</creatorcontrib><creatorcontrib>Ernst, Manuela</creatorcontrib><creatorcontrib>Varga, Peter</creatorcontrib><creatorcontrib>Schwarzenberg, Peter</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of orthopaedic research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hetreau, Carla</au><au>Mischler, Dominic</au><au>Schlatter, Jérôme</au><au>Valenti, Alessia</au><au>Ernst, Manuela</au><au>Varga, Peter</au><au>Schwarzenberg, Peter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Longitudinal CT-based finite element analyses provide objective fracture healing measures in an ovine tibia model</atitle><jtitle>Journal of orthopaedic research</jtitle><addtitle>J Orthop Res</addtitle><date>2024-08-01</date><risdate>2024</risdate><volume>42</volume><issue>8</issue><spage>1762</spage><epage>1770</epage><pages>1762-1770</pages><issn>0736-0266</issn><issn>1554-527X</issn><eissn>1554-527X</eissn><abstract>Measuring the healing status of a bone fracture is important to determine the clinical care a patient receives. Implantable devices can directly and continuously assess the healing status of fracture fixation constructs, while subject-specific virtual biomechanical tests can noninvasively determine callus structural integrity at single time points. Despite their potential for objectification, both methods are not yet integrated into clinical practice with further evidence of their benefits required. This study correlated continuous data from an implantable sensor assessing healing status through implant load monitoring with computer tomography (CT) based longitudinal finite element (FE) simulations in a large animal model. Eight sheep were part of a previous preclinical study utilizing a tibial osteotomy model and equipped with such a sensor. Sensor signal was collected over several months, and CT scans were acquired at six interim time points. For each scan, two FE analyses were performed: a virtual torsional rigidity test of the bone and a model of the bone-implant construct with the sensor. The longitudinal simulation results were compared to the sensor data at corresponding time points and a cohort-specific empirical healing rule was employed. Healing status predicted by both in silico simulations correlated significantly with the sensor data at corresponding time points and correctly identified a delayed and a nonunion in the cohort. The methodology is readily translatable with the potential to be applied to further preclinical or clinical cohorts to find generalizable healing criteria. Virtual mechanical tests can objectively measure fracture healing progressing using longitudinal CT scans.</abstract><cop>United States</cop><pmid>38483000</pmid><doi>10.1002/jor.25838</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-8747-6786</orcidid><orcidid>https://orcid.org/0000-0003-2738-6436</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0736-0266
ispartof Journal of orthopaedic research, 2024-08, Vol.42 (8), p.1762-1770
issn 0736-0266
1554-527X
1554-527X
language eng
recordid cdi_proquest_miscellaneous_2957168925
source Wiley-Blackwell Read & Publish Collection
subjects Animals
Female
Finite Element Analysis
Fracture Healing
Sheep
Tibia - diagnostic imaging
Tibial Fractures - diagnostic imaging
Tibial Fractures - physiopathology
Tibial Fractures - surgery
Tomography, X-Ray Computed
title Longitudinal CT-based finite element analyses provide objective fracture healing measures in an ovine tibia model
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T19%3A47%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Longitudinal%20CT-based%20finite%20element%20analyses%20provide%20objective%20fracture%20healing%20measures%20in%20an%20ovine%20tibia%20model&rft.jtitle=Journal%20of%20orthopaedic%20research&rft.au=Hetreau,%20Carla&rft.date=2024-08-01&rft.volume=42&rft.issue=8&rft.spage=1762&rft.epage=1770&rft.pages=1762-1770&rft.issn=0736-0266&rft.eissn=1554-527X&rft_id=info:doi/10.1002/jor.25838&rft_dat=%3Cproquest_cross%3E2957168925%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c245t-a2fc83de438bc985815a75e54c52aaafb9fb70d3cc678c06ee2c5229a24335ee3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2957168925&rft_id=info:pmid/38483000&rfr_iscdi=true