Loading…

A simple auto-tuner in frequency domain

A new frequency domain controller design method is proposed based on process frequency response data identified through relay feedback test. Multiple points on Nyquist curve are used. A desired closed-loop model is specified and controller parameters are computed using least squares method. The cont...

Full description

Saved in:
Bibliographic Details
Published in:Computers & chemical engineering 2006-02, Vol.30 (4), p.581-586
Main Authors: Ma, Ming-da, Zhu, Xin-jian
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A new frequency domain controller design method is proposed based on process frequency response data identified through relay feedback test. Multiple points on Nyquist curve are used. A desired closed-loop model is specified and controller parameters are computed using least squares method. The controller is equal to PI or PID controller when it is of low order. The procedures are tested against linear systems with and without noise. Compared with most methods, which use only one point on Nyquist curve, this method has obvious superiority.
ISSN:0098-1354
1873-4375
DOI:10.1016/j.compchemeng.2005.09.004