Loading…

Outcome determinants for coronal shear fractures of the distal humerus

Purpose Coronal shear fractures of the distal humerus involving the capitellum and trochlea are rare injuries. Internal fixation with headless compression screws provides a stable construct facilitating early mobilisation. Our study aimed to identify the key determinants of both radiological and fun...

Full description

Saved in:
Bibliographic Details
Published in:International orthopaedics 2024-05, Vol.48 (5), p.1295-1302
Main Authors: Nagashree, Vasudeva, Dheenadhayalan, Jayaramaraju, Sundaram, Velmurugesan Purnaganapathi, Zackariya, Mohammed, Sivakumar, SP, Vembanan, Kavinkumar, Rajasekaran, Shanmuganathan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c298t-6f1cf6768f049c2f9f893038e9201642717f93ee49c657ab78b9586671f62b2f3
container_end_page 1302
container_issue 5
container_start_page 1295
container_title International orthopaedics
container_volume 48
creator Nagashree, Vasudeva
Dheenadhayalan, Jayaramaraju
Sundaram, Velmurugesan Purnaganapathi
Zackariya, Mohammed
Sivakumar, SP
Vembanan, Kavinkumar
Rajasekaran, Shanmuganathan
description Purpose Coronal shear fractures of the distal humerus involving the capitellum and trochlea are rare injuries. Internal fixation with headless compression screws provides a stable construct facilitating early mobilisation. Our study aimed to identify the key determinants of both radiological and functional outcomes of patients with distal humerus coronal shear fractures treated with internal fixation. Methods A retrospective analysis of 61 patients with distal humerus coronal shear fractures who were treated surgically was done. Demographics, fracture morphology, time to surgery, operative details such as surgical approach and implant used, quality of reduction, time to union, and associated complications from hospital records. Radiological outcomes were assessed using plain radiographs, and the functional outcomes were by Oxford Elbow Score (OES) and Mayo Elbow Performance Index (MEPI). Results Patients with anatomical reduction of the fracture had better functional outcomes and range of motion. The presence of posterior comminution of capitellum resulted in poorer outcomes ( p  = 0.03). Delayed presentation did not alter the outcome when the anatomical reduction was achieved. Myositis ossificans was noted in nine patients and non-union in five patients. Two patients developed avascular necrosis of the capitellum and arthritis of the elbow joint. Conclusion Anatomical reduction and posterior comminution are the two key determinants of the functional outcome in these coronal shear fractures of the distal humerus. Early mobilisation following a stable fixation is crucial in achieving a good outcome.
doi_str_mv 10.1007/s00264-024-06151-2
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2972702168</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2972702168</sourcerecordid><originalsourceid>FETCH-LOGICAL-c298t-6f1cf6768f049c2f9f893038e9201642717f93ee49c657ab78b9586671f62b2f3</originalsourceid><addsrcrecordid>eNp9kD1PwzAURS0EoqXwBxhQRpaAPxI7HlFFAalSF5gtx32mqZK4-GPg32NIYWR4svTueVfWQeia4DuCsbgPGFNelZjm4aQmJT1Bc1IxWtZE1qdojlmVl1zWM3QRwh5jInhDztGMNTWmjIk5Wm1SNG6AYgsR_NCNeoyhsM4Xxnk36r4IO9C-sF6bmDyEwtki7jLfhZjTXRrAp3CJzqzuA1wd3wV6Wz2-Lp_L9ebpZfmwLg2VTSy5Jcby_AmLK2molbaRDLMGJMWEV1QQYSUDyCGvhW5F08q64VwQy2lLLVug26n34N1HghDV0AUDfa9HcCkoKgUVmBLeZJROqPEuBA9WHXw3aP-pCFbf_tTkT2V_6sefovno5tif2gG2fye_wjLAJiDkaHwHr_Yu-ewp_Ff7Bfceei0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2972702168</pqid></control><display><type>article</type><title>Outcome determinants for coronal shear fractures of the distal humerus</title><source>Springer Link</source><creator>Nagashree, Vasudeva ; Dheenadhayalan, Jayaramaraju ; Sundaram, Velmurugesan Purnaganapathi ; Zackariya, Mohammed ; Sivakumar, SP ; Vembanan, Kavinkumar ; Rajasekaran, Shanmuganathan</creator><creatorcontrib>Nagashree, Vasudeva ; Dheenadhayalan, Jayaramaraju ; Sundaram, Velmurugesan Purnaganapathi ; Zackariya, Mohammed ; Sivakumar, SP ; Vembanan, Kavinkumar ; Rajasekaran, Shanmuganathan</creatorcontrib><description>Purpose Coronal shear fractures of the distal humerus involving the capitellum and trochlea are rare injuries. Internal fixation with headless compression screws provides a stable construct facilitating early mobilisation. Our study aimed to identify the key determinants of both radiological and functional outcomes of patients with distal humerus coronal shear fractures treated with internal fixation. Methods A retrospective analysis of 61 patients with distal humerus coronal shear fractures who were treated surgically was done. Demographics, fracture morphology, time to surgery, operative details such as surgical approach and implant used, quality of reduction, time to union, and associated complications from hospital records. Radiological outcomes were assessed using plain radiographs, and the functional outcomes were by Oxford Elbow Score (OES) and Mayo Elbow Performance Index (MEPI). Results Patients with anatomical reduction of the fracture had better functional outcomes and range of motion. The presence of posterior comminution of capitellum resulted in poorer outcomes ( p  = 0.03). Delayed presentation did not alter the outcome when the anatomical reduction was achieved. Myositis ossificans was noted in nine patients and non-union in five patients. Two patients developed avascular necrosis of the capitellum and arthritis of the elbow joint. Conclusion Anatomical reduction and posterior comminution are the two key determinants of the functional outcome in these coronal shear fractures of the distal humerus. Early mobilisation following a stable fixation is crucial in achieving a good outcome.</description><identifier>ISSN: 0341-2695</identifier><identifier>EISSN: 1432-5195</identifier><identifier>DOI: 10.1007/s00264-024-06151-2</identifier><identifier>PMID: 38502337</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Medicine ; Medicine &amp; Public Health ; Original Paper ; Orthopedics</subject><ispartof>International orthopaedics, 2024-05, Vol.48 (5), p.1295-1302</ispartof><rights>The Author(s) under exclusive licence to SICOT aisbl 2024. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><rights>2024. The Author(s) under exclusive licence to SICOT aisbl.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c298t-6f1cf6768f049c2f9f893038e9201642717f93ee49c657ab78b9586671f62b2f3</cites><orcidid>0000-0002-6896-3255 ; 0000-0001-6043-006X ; 0000-0002-8461-0767 ; 0000-0002-1295-136X ; 0000-0002-5713-2616 ; 0000-0002-4381-1108 ; 0000-0003-4087-2316</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38502337$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nagashree, Vasudeva</creatorcontrib><creatorcontrib>Dheenadhayalan, Jayaramaraju</creatorcontrib><creatorcontrib>Sundaram, Velmurugesan Purnaganapathi</creatorcontrib><creatorcontrib>Zackariya, Mohammed</creatorcontrib><creatorcontrib>Sivakumar, SP</creatorcontrib><creatorcontrib>Vembanan, Kavinkumar</creatorcontrib><creatorcontrib>Rajasekaran, Shanmuganathan</creatorcontrib><title>Outcome determinants for coronal shear fractures of the distal humerus</title><title>International orthopaedics</title><addtitle>International Orthopaedics (SICOT)</addtitle><addtitle>Int Orthop</addtitle><description>Purpose Coronal shear fractures of the distal humerus involving the capitellum and trochlea are rare injuries. Internal fixation with headless compression screws provides a stable construct facilitating early mobilisation. Our study aimed to identify the key determinants of both radiological and functional outcomes of patients with distal humerus coronal shear fractures treated with internal fixation. Methods A retrospective analysis of 61 patients with distal humerus coronal shear fractures who were treated surgically was done. Demographics, fracture morphology, time to surgery, operative details such as surgical approach and implant used, quality of reduction, time to union, and associated complications from hospital records. Radiological outcomes were assessed using plain radiographs, and the functional outcomes were by Oxford Elbow Score (OES) and Mayo Elbow Performance Index (MEPI). Results Patients with anatomical reduction of the fracture had better functional outcomes and range of motion. The presence of posterior comminution of capitellum resulted in poorer outcomes ( p  = 0.03). Delayed presentation did not alter the outcome when the anatomical reduction was achieved. Myositis ossificans was noted in nine patients and non-union in five patients. Two patients developed avascular necrosis of the capitellum and arthritis of the elbow joint. Conclusion Anatomical reduction and posterior comminution are the two key determinants of the functional outcome in these coronal shear fractures of the distal humerus. Early mobilisation following a stable fixation is crucial in achieving a good outcome.</description><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Original Paper</subject><subject>Orthopedics</subject><issn>0341-2695</issn><issn>1432-5195</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PwzAURS0EoqXwBxhQRpaAPxI7HlFFAalSF5gtx32mqZK4-GPg32NIYWR4svTueVfWQeia4DuCsbgPGFNelZjm4aQmJT1Bc1IxWtZE1qdojlmVl1zWM3QRwh5jInhDztGMNTWmjIk5Wm1SNG6AYgsR_NCNeoyhsM4Xxnk36r4IO9C-sF6bmDyEwtki7jLfhZjTXRrAp3CJzqzuA1wd3wV6Wz2-Lp_L9ebpZfmwLg2VTSy5Jcby_AmLK2molbaRDLMGJMWEV1QQYSUDyCGvhW5F08q64VwQy2lLLVug26n34N1HghDV0AUDfa9HcCkoKgUVmBLeZJROqPEuBA9WHXw3aP-pCFbf_tTkT2V_6sefovno5tif2gG2fye_wjLAJiDkaHwHr_Yu-ewp_Ff7Bfceei0</recordid><startdate>20240501</startdate><enddate>20240501</enddate><creator>Nagashree, Vasudeva</creator><creator>Dheenadhayalan, Jayaramaraju</creator><creator>Sundaram, Velmurugesan Purnaganapathi</creator><creator>Zackariya, Mohammed</creator><creator>Sivakumar, SP</creator><creator>Vembanan, Kavinkumar</creator><creator>Rajasekaran, Shanmuganathan</creator><general>Springer Berlin Heidelberg</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-6896-3255</orcidid><orcidid>https://orcid.org/0000-0001-6043-006X</orcidid><orcidid>https://orcid.org/0000-0002-8461-0767</orcidid><orcidid>https://orcid.org/0000-0002-1295-136X</orcidid><orcidid>https://orcid.org/0000-0002-5713-2616</orcidid><orcidid>https://orcid.org/0000-0002-4381-1108</orcidid><orcidid>https://orcid.org/0000-0003-4087-2316</orcidid></search><sort><creationdate>20240501</creationdate><title>Outcome determinants for coronal shear fractures of the distal humerus</title><author>Nagashree, Vasudeva ; Dheenadhayalan, Jayaramaraju ; Sundaram, Velmurugesan Purnaganapathi ; Zackariya, Mohammed ; Sivakumar, SP ; Vembanan, Kavinkumar ; Rajasekaran, Shanmuganathan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c298t-6f1cf6768f049c2f9f893038e9201642717f93ee49c657ab78b9586671f62b2f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Original Paper</topic><topic>Orthopedics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nagashree, Vasudeva</creatorcontrib><creatorcontrib>Dheenadhayalan, Jayaramaraju</creatorcontrib><creatorcontrib>Sundaram, Velmurugesan Purnaganapathi</creatorcontrib><creatorcontrib>Zackariya, Mohammed</creatorcontrib><creatorcontrib>Sivakumar, SP</creatorcontrib><creatorcontrib>Vembanan, Kavinkumar</creatorcontrib><creatorcontrib>Rajasekaran, Shanmuganathan</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International orthopaedics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nagashree, Vasudeva</au><au>Dheenadhayalan, Jayaramaraju</au><au>Sundaram, Velmurugesan Purnaganapathi</au><au>Zackariya, Mohammed</au><au>Sivakumar, SP</au><au>Vembanan, Kavinkumar</au><au>Rajasekaran, Shanmuganathan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Outcome determinants for coronal shear fractures of the distal humerus</atitle><jtitle>International orthopaedics</jtitle><stitle>International Orthopaedics (SICOT)</stitle><addtitle>Int Orthop</addtitle><date>2024-05-01</date><risdate>2024</risdate><volume>48</volume><issue>5</issue><spage>1295</spage><epage>1302</epage><pages>1295-1302</pages><issn>0341-2695</issn><eissn>1432-5195</eissn><abstract>Purpose Coronal shear fractures of the distal humerus involving the capitellum and trochlea are rare injuries. Internal fixation with headless compression screws provides a stable construct facilitating early mobilisation. Our study aimed to identify the key determinants of both radiological and functional outcomes of patients with distal humerus coronal shear fractures treated with internal fixation. Methods A retrospective analysis of 61 patients with distal humerus coronal shear fractures who were treated surgically was done. Demographics, fracture morphology, time to surgery, operative details such as surgical approach and implant used, quality of reduction, time to union, and associated complications from hospital records. Radiological outcomes were assessed using plain radiographs, and the functional outcomes were by Oxford Elbow Score (OES) and Mayo Elbow Performance Index (MEPI). Results Patients with anatomical reduction of the fracture had better functional outcomes and range of motion. The presence of posterior comminution of capitellum resulted in poorer outcomes ( p  = 0.03). Delayed presentation did not alter the outcome when the anatomical reduction was achieved. Myositis ossificans was noted in nine patients and non-union in five patients. Two patients developed avascular necrosis of the capitellum and arthritis of the elbow joint. Conclusion Anatomical reduction and posterior comminution are the two key determinants of the functional outcome in these coronal shear fractures of the distal humerus. Early mobilisation following a stable fixation is crucial in achieving a good outcome.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>38502337</pmid><doi>10.1007/s00264-024-06151-2</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-6896-3255</orcidid><orcidid>https://orcid.org/0000-0001-6043-006X</orcidid><orcidid>https://orcid.org/0000-0002-8461-0767</orcidid><orcidid>https://orcid.org/0000-0002-1295-136X</orcidid><orcidid>https://orcid.org/0000-0002-5713-2616</orcidid><orcidid>https://orcid.org/0000-0002-4381-1108</orcidid><orcidid>https://orcid.org/0000-0003-4087-2316</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0341-2695
ispartof International orthopaedics, 2024-05, Vol.48 (5), p.1295-1302
issn 0341-2695
1432-5195
language eng
recordid cdi_proquest_miscellaneous_2972702168
source Springer Link
subjects Medicine
Medicine & Public Health
Original Paper
Orthopedics
title Outcome determinants for coronal shear fractures of the distal humerus
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T13%3A36%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Outcome%20determinants%20for%20coronal%20shear%20fractures%20of%20the%20distal%20humerus&rft.jtitle=International%20orthopaedics&rft.au=Nagashree,%20Vasudeva&rft.date=2024-05-01&rft.volume=48&rft.issue=5&rft.spage=1295&rft.epage=1302&rft.pages=1295-1302&rft.issn=0341-2695&rft.eissn=1432-5195&rft_id=info:doi/10.1007/s00264-024-06151-2&rft_dat=%3Cproquest_cross%3E2972702168%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c298t-6f1cf6768f049c2f9f893038e9201642717f93ee49c657ab78b9586671f62b2f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2972702168&rft_id=info:pmid/38502337&rfr_iscdi=true