Finding the inversion temperature for water evaporation into an air–steam mixture

This paper deals with adiabatic evaporation of water into an air–steam mixture and pure superheated steam. The focus is made on the inversion temperature, which means that the rate of liquid evaporation into superheated steam becomes equal to the rate of evaporation into dry air. A simple analytical...

Full description

Saved in:
Bibliographic Details
Published in:International journal of heat and mass transfer 2007-06, Vol.50 (11), p.2101-2106
Main Authors: Volchkov, E.P., Leontiev, A.I., Makarova, S.N.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This paper deals with adiabatic evaporation of water into an air–steam mixture and pure superheated steam. The focus is made on the inversion temperature, which means that the rate of liquid evaporation into superheated steam becomes equal to the rate of evaporation into dry air. A simple analytical solution for the inversion temperature was derived. The analytical and numerical methods were applied for analysis of different factors (vapor quantity, flow rate, flow regime) on the value of inversion temperature.
ISSN:0017-9310
1879-2189
DOI:10.1016/j.ijheatmasstransfer.2006.11.010