Finding the inversion temperature for water evaporation into an air–steam mixture
This paper deals with adiabatic evaporation of water into an air–steam mixture and pure superheated steam. The focus is made on the inversion temperature, which means that the rate of liquid evaporation into superheated steam becomes equal to the rate of evaporation into dry air. A simple analytical...
Saved in:
Published in: | International journal of heat and mass transfer 2007-06, Vol.50 (11), p.2101-2106 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This paper deals with adiabatic evaporation of water into an air–steam mixture and pure superheated steam. The focus is made on the inversion temperature, which means that the rate of liquid evaporation into superheated steam becomes equal to the rate of evaporation into dry air. A simple analytical solution for the inversion temperature was derived. The analytical and numerical methods were applied for analysis of different factors (vapor quantity, flow rate, flow regime) on the value of inversion temperature. |
---|---|
ISSN: | 0017-9310 1879-2189 |