Loading…

Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein

Cadmium poses a severe health risk, impacting various bodily systems. Monitoring human exposure is vital. Urine and blood cadmium serve as critical biomarkers. However, current urine and blood cadmium detection methods are expensive and complex. Being cost-effective, user-friendly, and efficient, vi...

Full description

Saved in:
Bibliographic Details
Published in:ACS biomaterials science & engineering 2024-06, Vol.10 (6), p.4046-4058
Main Authors: Zhang, Juan, Guo, Yan, Lin, Yi-ran, Ma, Bing-chan, Ge, Xue-ru, Zhang, Wen-qi, Zhang, Nai-xing, Yang, Shu-man, Hui, Chang-ye
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a357t-fbcb77adff3dbb423deb3ac72842ee744a71a775cd2b236dc2d4747af9be7f6c3
cites cdi_FETCH-LOGICAL-a357t-fbcb77adff3dbb423deb3ac72842ee744a71a775cd2b236dc2d4747af9be7f6c3
container_end_page 4058
container_issue 6
container_start_page 4046
container_title ACS biomaterials science & engineering
container_volume 10
creator Zhang, Juan
Guo, Yan
Lin, Yi-ran
Ma, Bing-chan
Ge, Xue-ru
Zhang, Wen-qi
Zhang, Nai-xing
Yang, Shu-man
Hui, Chang-ye
description Cadmium poses a severe health risk, impacting various bodily systems. Monitoring human exposure is vital. Urine and blood cadmium serve as critical biomarkers. However, current urine and blood cadmium detection methods are expensive and complex. Being cost-effective, user-friendly, and efficient, visual biosensing offers a promising complement to existing techniques. Therefore, we constructed a cadmium whole-cell biosensor using CadR10 and deoxyviolacein pigment in this study. We assessed the sensor for time–dose response, specific response to cadmium, sensitivity response to cadmium, and stability response to cadmium. The results showed that (1) the sensor had a preferred signal-to-noise ratio when the incubation time was 4 h; (2) the sensor showed excellent specificity for cadmium compared to the group 12 metals and lead; (3) the sensor was responsive to cadmium down to 1.53 nM under experimental conditions and had good linearity over a wide range from 1.53 nM to 100 μM with good linearity (R 2 = 0.979); and (4) the sensor had good stability. Based on the excellent results of the performance tests, we developed a cost-effective, high-throughput method for detecting urinary and blood cadmium. Specifically, this was realized by adding the blood or urine samples into the culture system in a particular proportion. Then, the whole-cell biosensor was subjected to culture, n-butanol extraction, and microplate reading. The results showed that (1) at 20% urine addition ratio, the sensor had an excellent curvilinear relationship (R 2 = 0.986) in the range of 3.05 nM to 100 μM, and the detection limit could reach 3.05 nM. (2) At a 10% blood addition ratio, the sensor had an excellent nonlinear relationship (R 2 = 0.978) in the range of 0.097–50 μM, and the detection limit reached 0.195 μM. Overall, we developed a sensitive and wide-range method based on a whole-cell biosensor for the detection of cadmium in blood and urine, which has the advantages of being cost-effective, ease of operation, fast response, and low dependence on instrumentation and has the potential to be applied in the monitoring of cadmium exposure in humans as a complementary to the mainstream detection techniques.
doi_str_mv 10.1021/acsbiomaterials.3c01814
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3053979840</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3053979840</sourcerecordid><originalsourceid>FETCH-LOGICAL-a357t-fbcb77adff3dbb423deb3ac72842ee744a71a775cd2b236dc2d4747af9be7f6c3</originalsourceid><addsrcrecordid>eNqFkD9PwzAUxC0EolXpVwCPLCmO7dTJSFOgSJUYADFG_vMiXCVxiZOKfntc2iLEwvRu-N290yF0FZNJTGh8I7VX1tWyg9bKyk-YJnEa8xM0pEywKEtFevpLD9DY-xUhJGZpwjk_RwOWCkqDHqJmDh3ozroGuxLn0tS2r7Ft8KKvZYNn1vk1aFtD47HaYnlEomeodr4N4Ld3V0GUQ1V944F0LZ5JDwaH1Dm4z-3GukpqsM0FOitDZRgf7gi93t-95Ito-fTwmN8uI8kS0UWl0koIacqSGaU4ZQYUk1rQlFMAwbkUsRQi0YYqyqZGU8MFF7LMFIhyqtkIXe9z16376MF3RW29DhVlA673BSMJy0SWchJQsUd167xvoSzWra1luy1iUuz2Lv7sXRz2Ds7Lw5Ne1WB-fMd1A8D2QEgoVq5vm539v9gvXYeUnQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3053979840</pqid></control><display><type>article</type><title>Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Zhang, Juan ; Guo, Yan ; Lin, Yi-ran ; Ma, Bing-chan ; Ge, Xue-ru ; Zhang, Wen-qi ; Zhang, Nai-xing ; Yang, Shu-man ; Hui, Chang-ye</creator><creatorcontrib>Zhang, Juan ; Guo, Yan ; Lin, Yi-ran ; Ma, Bing-chan ; Ge, Xue-ru ; Zhang, Wen-qi ; Zhang, Nai-xing ; Yang, Shu-man ; Hui, Chang-ye</creatorcontrib><description>Cadmium poses a severe health risk, impacting various bodily systems. Monitoring human exposure is vital. Urine and blood cadmium serve as critical biomarkers. However, current urine and blood cadmium detection methods are expensive and complex. Being cost-effective, user-friendly, and efficient, visual biosensing offers a promising complement to existing techniques. Therefore, we constructed a cadmium whole-cell biosensor using CadR10 and deoxyviolacein pigment in this study. We assessed the sensor for time–dose response, specific response to cadmium, sensitivity response to cadmium, and stability response to cadmium. The results showed that (1) the sensor had a preferred signal-to-noise ratio when the incubation time was 4 h; (2) the sensor showed excellent specificity for cadmium compared to the group 12 metals and lead; (3) the sensor was responsive to cadmium down to 1.53 nM under experimental conditions and had good linearity over a wide range from 1.53 nM to 100 μM with good linearity (R 2 = 0.979); and (4) the sensor had good stability. Based on the excellent results of the performance tests, we developed a cost-effective, high-throughput method for detecting urinary and blood cadmium. Specifically, this was realized by adding the blood or urine samples into the culture system in a particular proportion. Then, the whole-cell biosensor was subjected to culture, n-butanol extraction, and microplate reading. The results showed that (1) at 20% urine addition ratio, the sensor had an excellent curvilinear relationship (R 2 = 0.986) in the range of 3.05 nM to 100 μM, and the detection limit could reach 3.05 nM. (2) At a 10% blood addition ratio, the sensor had an excellent nonlinear relationship (R 2 = 0.978) in the range of 0.097–50 μM, and the detection limit reached 0.195 μM. Overall, we developed a sensitive and wide-range method based on a whole-cell biosensor for the detection of cadmium in blood and urine, which has the advantages of being cost-effective, ease of operation, fast response, and low dependence on instrumentation and has the potential to be applied in the monitoring of cadmium exposure in humans as a complementary to the mainstream detection techniques.</description><identifier>ISSN: 2373-9878</identifier><identifier>EISSN: 2373-9878</identifier><identifier>DOI: 10.1021/acsbiomaterials.3c01814</identifier><identifier>PMID: 38722544</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Biosensing Techniques - methods ; Cadmium - analysis ; Cadmium - blood ; Cadmium - urine ; Humans ; Limit of Detection ; Manufacturing, Technology, and Devices</subject><ispartof>ACS biomaterials science &amp; engineering, 2024-06, Vol.10 (6), p.4046-4058</ispartof><rights>2024 American Chemical Society</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a357t-fbcb77adff3dbb423deb3ac72842ee744a71a775cd2b236dc2d4747af9be7f6c3</citedby><cites>FETCH-LOGICAL-a357t-fbcb77adff3dbb423deb3ac72842ee744a71a775cd2b236dc2d4747af9be7f6c3</cites><orcidid>0009-0003-0795-1749 ; 0000-0002-0958-1986 ; 0009-0006-4521-3407</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38722544$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhang, Juan</creatorcontrib><creatorcontrib>Guo, Yan</creatorcontrib><creatorcontrib>Lin, Yi-ran</creatorcontrib><creatorcontrib>Ma, Bing-chan</creatorcontrib><creatorcontrib>Ge, Xue-ru</creatorcontrib><creatorcontrib>Zhang, Wen-qi</creatorcontrib><creatorcontrib>Zhang, Nai-xing</creatorcontrib><creatorcontrib>Yang, Shu-man</creatorcontrib><creatorcontrib>Hui, Chang-ye</creatorcontrib><title>Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein</title><title>ACS biomaterials science &amp; engineering</title><addtitle>ACS Biomater. Sci. Eng</addtitle><description>Cadmium poses a severe health risk, impacting various bodily systems. Monitoring human exposure is vital. Urine and blood cadmium serve as critical biomarkers. However, current urine and blood cadmium detection methods are expensive and complex. Being cost-effective, user-friendly, and efficient, visual biosensing offers a promising complement to existing techniques. Therefore, we constructed a cadmium whole-cell biosensor using CadR10 and deoxyviolacein pigment in this study. We assessed the sensor for time–dose response, specific response to cadmium, sensitivity response to cadmium, and stability response to cadmium. The results showed that (1) the sensor had a preferred signal-to-noise ratio when the incubation time was 4 h; (2) the sensor showed excellent specificity for cadmium compared to the group 12 metals and lead; (3) the sensor was responsive to cadmium down to 1.53 nM under experimental conditions and had good linearity over a wide range from 1.53 nM to 100 μM with good linearity (R 2 = 0.979); and (4) the sensor had good stability. Based on the excellent results of the performance tests, we developed a cost-effective, high-throughput method for detecting urinary and blood cadmium. Specifically, this was realized by adding the blood or urine samples into the culture system in a particular proportion. Then, the whole-cell biosensor was subjected to culture, n-butanol extraction, and microplate reading. The results showed that (1) at 20% urine addition ratio, the sensor had an excellent curvilinear relationship (R 2 = 0.986) in the range of 3.05 nM to 100 μM, and the detection limit could reach 3.05 nM. (2) At a 10% blood addition ratio, the sensor had an excellent nonlinear relationship (R 2 = 0.978) in the range of 0.097–50 μM, and the detection limit reached 0.195 μM. Overall, we developed a sensitive and wide-range method based on a whole-cell biosensor for the detection of cadmium in blood and urine, which has the advantages of being cost-effective, ease of operation, fast response, and low dependence on instrumentation and has the potential to be applied in the monitoring of cadmium exposure in humans as a complementary to the mainstream detection techniques.</description><subject>Biosensing Techniques - methods</subject><subject>Cadmium - analysis</subject><subject>Cadmium - blood</subject><subject>Cadmium - urine</subject><subject>Humans</subject><subject>Limit of Detection</subject><subject>Manufacturing, Technology, and Devices</subject><issn>2373-9878</issn><issn>2373-9878</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkD9PwzAUxC0EolXpVwCPLCmO7dTJSFOgSJUYADFG_vMiXCVxiZOKfntc2iLEwvRu-N290yF0FZNJTGh8I7VX1tWyg9bKyk-YJnEa8xM0pEywKEtFevpLD9DY-xUhJGZpwjk_RwOWCkqDHqJmDh3ozroGuxLn0tS2r7Ft8KKvZYNn1vk1aFtD47HaYnlEomeodr4N4Ld3V0GUQ1V944F0LZ5JDwaH1Dm4z-3GukpqsM0FOitDZRgf7gi93t-95Ito-fTwmN8uI8kS0UWl0koIacqSGaU4ZQYUk1rQlFMAwbkUsRQi0YYqyqZGU8MFF7LMFIhyqtkIXe9z16376MF3RW29DhVlA673BSMJy0SWchJQsUd167xvoSzWra1luy1iUuz2Lv7sXRz2Ds7Lw5Ne1WB-fMd1A8D2QEgoVq5vm539v9gvXYeUnQ</recordid><startdate>20240610</startdate><enddate>20240610</enddate><creator>Zhang, Juan</creator><creator>Guo, Yan</creator><creator>Lin, Yi-ran</creator><creator>Ma, Bing-chan</creator><creator>Ge, Xue-ru</creator><creator>Zhang, Wen-qi</creator><creator>Zhang, Nai-xing</creator><creator>Yang, Shu-man</creator><creator>Hui, Chang-ye</creator><general>American Chemical Society</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0009-0003-0795-1749</orcidid><orcidid>https://orcid.org/0000-0002-0958-1986</orcidid><orcidid>https://orcid.org/0009-0006-4521-3407</orcidid></search><sort><creationdate>20240610</creationdate><title>Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein</title><author>Zhang, Juan ; Guo, Yan ; Lin, Yi-ran ; Ma, Bing-chan ; Ge, Xue-ru ; Zhang, Wen-qi ; Zhang, Nai-xing ; Yang, Shu-man ; Hui, Chang-ye</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a357t-fbcb77adff3dbb423deb3ac72842ee744a71a775cd2b236dc2d4747af9be7f6c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Biosensing Techniques - methods</topic><topic>Cadmium - analysis</topic><topic>Cadmium - blood</topic><topic>Cadmium - urine</topic><topic>Humans</topic><topic>Limit of Detection</topic><topic>Manufacturing, Technology, and Devices</topic><toplevel>online_resources</toplevel><creatorcontrib>Zhang, Juan</creatorcontrib><creatorcontrib>Guo, Yan</creatorcontrib><creatorcontrib>Lin, Yi-ran</creatorcontrib><creatorcontrib>Ma, Bing-chan</creatorcontrib><creatorcontrib>Ge, Xue-ru</creatorcontrib><creatorcontrib>Zhang, Wen-qi</creatorcontrib><creatorcontrib>Zhang, Nai-xing</creatorcontrib><creatorcontrib>Yang, Shu-man</creatorcontrib><creatorcontrib>Hui, Chang-ye</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>ACS biomaterials science &amp; engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhang, Juan</au><au>Guo, Yan</au><au>Lin, Yi-ran</au><au>Ma, Bing-chan</au><au>Ge, Xue-ru</au><au>Zhang, Wen-qi</au><au>Zhang, Nai-xing</au><au>Yang, Shu-man</au><au>Hui, Chang-ye</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein</atitle><jtitle>ACS biomaterials science &amp; engineering</jtitle><addtitle>ACS Biomater. Sci. Eng</addtitle><date>2024-06-10</date><risdate>2024</risdate><volume>10</volume><issue>6</issue><spage>4046</spage><epage>4058</epage><pages>4046-4058</pages><issn>2373-9878</issn><eissn>2373-9878</eissn><abstract>Cadmium poses a severe health risk, impacting various bodily systems. Monitoring human exposure is vital. Urine and blood cadmium serve as critical biomarkers. However, current urine and blood cadmium detection methods are expensive and complex. Being cost-effective, user-friendly, and efficient, visual biosensing offers a promising complement to existing techniques. Therefore, we constructed a cadmium whole-cell biosensor using CadR10 and deoxyviolacein pigment in this study. We assessed the sensor for time–dose response, specific response to cadmium, sensitivity response to cadmium, and stability response to cadmium. The results showed that (1) the sensor had a preferred signal-to-noise ratio when the incubation time was 4 h; (2) the sensor showed excellent specificity for cadmium compared to the group 12 metals and lead; (3) the sensor was responsive to cadmium down to 1.53 nM under experimental conditions and had good linearity over a wide range from 1.53 nM to 100 μM with good linearity (R 2 = 0.979); and (4) the sensor had good stability. Based on the excellent results of the performance tests, we developed a cost-effective, high-throughput method for detecting urinary and blood cadmium. Specifically, this was realized by adding the blood or urine samples into the culture system in a particular proportion. Then, the whole-cell biosensor was subjected to culture, n-butanol extraction, and microplate reading. The results showed that (1) at 20% urine addition ratio, the sensor had an excellent curvilinear relationship (R 2 = 0.986) in the range of 3.05 nM to 100 μM, and the detection limit could reach 3.05 nM. (2) At a 10% blood addition ratio, the sensor had an excellent nonlinear relationship (R 2 = 0.978) in the range of 0.097–50 μM, and the detection limit reached 0.195 μM. Overall, we developed a sensitive and wide-range method based on a whole-cell biosensor for the detection of cadmium in blood and urine, which has the advantages of being cost-effective, ease of operation, fast response, and low dependence on instrumentation and has the potential to be applied in the monitoring of cadmium exposure in humans as a complementary to the mainstream detection techniques.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>38722544</pmid><doi>10.1021/acsbiomaterials.3c01814</doi><tpages>13</tpages><orcidid>https://orcid.org/0009-0003-0795-1749</orcidid><orcidid>https://orcid.org/0000-0002-0958-1986</orcidid><orcidid>https://orcid.org/0009-0006-4521-3407</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2373-9878
ispartof ACS biomaterials science & engineering, 2024-06, Vol.10 (6), p.4046-4058
issn 2373-9878
2373-9878
language eng
recordid cdi_proquest_miscellaneous_3053979840
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
subjects Biosensing Techniques - methods
Cadmium - analysis
Cadmium - blood
Cadmium - urine
Humans
Limit of Detection
Manufacturing, Technology, and Devices
title Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T00%3A51%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Detection%20of%20Cadmium%20in%20Human%20Biospecimens%20by%20a%20Cadmium-Selective%20Whole-Cell%20Biosensor%20Based%20on%20Deoxyviolacein&rft.jtitle=ACS%20biomaterials%20science%20&%20engineering&rft.au=Zhang,%20Juan&rft.date=2024-06-10&rft.volume=10&rft.issue=6&rft.spage=4046&rft.epage=4058&rft.pages=4046-4058&rft.issn=2373-9878&rft.eissn=2373-9878&rft_id=info:doi/10.1021/acsbiomaterials.3c01814&rft_dat=%3Cproquest_cross%3E3053979840%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a357t-fbcb77adff3dbb423deb3ac72842ee744a71a775cd2b236dc2d4747af9be7f6c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3053979840&rft_id=info:pmid/38722544&rfr_iscdi=true