Loading…

The Evaluation of a Lateral Flow Strip Based on the Covalently Fixed “End-On” Orientation of an Antibody for Listeria monocytogenes Detection

In this study, the covalently fixed “end-on” orientation of a monoclonal Listeria monocytogenes antibody (mAb-Lis) to amino terminated oligo (ethylene glycol)-capped gold nanoparticles (NH2-TEG-AuNPs) was used to fabricate an in-house lateral flow strip (LFS), namely, the fixed “end-on” Lis-mAb-NH-T...

Full description

Saved in:
Bibliographic Details
Published in:Analytical chemistry (Washington) 2024-05, Vol.96 (21), p.8543-8551
Main Authors: Thongmee, Patsara, Ngernpimai, Sawinee, Srichaiyapol, Oranee, Mongmonsin, Urairat, Teerasong, Saowapak, Charoensri, Nicha, Wongwattanakul, Molin, Lulitanond, Aroonlug, Kuwatjanakul, Waewta, Wonglakorn, Lumyai, Kendal, Rinjong Promsorn, Chompoosor, Apiwat, Daduang, Jureerut, Tippayawat, Patcharaporn
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this study, the covalently fixed “end-on” orientation of a monoclonal Listeria monocytogenes antibody (mAb-Lis) to amino terminated oligo (ethylene glycol)-capped gold nanoparticles (NH2-TEG-AuNPs) was used to fabricate an in-house lateral flow strip (LFS), namely, the fixed “end-on” Lis-mAb-NH-TEG-AuNPs LFS. The aim was to evaluate the performance of the fixed “end-on” Lis-mAb-NH-TEG-AuNPs LFS in detecting L. monocytogenes. The proposed LFS enabled the sensitive detection of L. monocytogenes in 15 min with a visual limit of detection of 102 CFU/mL. Quantitative analysis indicated an LOD at 10 CFU/mL. The fixed “end-on” Lis-mAb-NH-TEG-AuNPs LFS showed no cross-reactivity with other pathogenic bacteria and practical performance across different food matrices, including human blood, milk, and mushroom samples. Furthermore, the clinical performance of the fixed “end-on” Lis-mAb-NH-TEG-AuNPs LFS for detecting L. monocytogenes was evaluated by using 12 clinical samples validated by the hemoculture method. It demonstrated excellent concordance with the reference methods, with no false-positive or false-negative results observed. Therefore, the fixed “end-on” Lis-mAb-NH-TEG-AuNPs LFS serves as a promising candidate for a point-of-care test (POCT), enabling the rapid, precise, and highly sensitive detection of L. monocytogenes in clinical samples and contaminated food.
ISSN:0003-2700
1520-6882
1520-6882
DOI:10.1021/acs.analchem.4c00533