Loading…

Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation

Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and tre...

Full description

Saved in:
Bibliographic Details
Published in:Resuscitation 2024-07, Vol.200, p.110259, Article 110259
Main Authors: Gutiérrez, Jose Julio, Urigüen, Jose Antonio, Leturiondo, Mikel, Sandoval, Camilo Leonardo, Redondo, Koldo, Russell, James Knox, Daya, Mohamud Ramzan, Ruiz de Gauna, Sofía
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3
container_end_page
container_issue
container_start_page 110259
container_title Resuscitation
container_volume 200
creator Gutiérrez, Jose Julio
Urigüen, Jose Antonio
Leturiondo, Mikel
Sandoval, Camilo Leonardo
Redondo, Koldo
Russell, James Knox
Daya, Mohamud Ramzan
Ruiz de Gauna, Sofía
description Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends. Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation. Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (–0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (–0.7 vs. –2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg). Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.
doi_str_mv 10.1016/j.resuscitation.2024.110259
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3063471683</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0300957224001527</els_id><sourcerecordid>3063471683</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3</originalsourceid><addsrcrecordid>eNqNkDtPxDAQhC0EEsfBf7BEQ5OwjuM8RIVOx0M66Qqgthx7Az4lcbATJP49CaG5jmqbmW9nhpBrBjEDlt0eYo9hDNoOarCuixNI0pgxSER5QlasyHnERA6nZAUcICpFnpyTixAOAMBFma_Ix8ugOqO8seEXQWulbTPzMFCPjVVVg9R2A_re4_KGuppuXzf7hJrR2-6dtqobVUP1jHH92LSuU_6bHmW7JGe1agJe_d01eXuYIE_Rbv_4vLnfRToBKCNTQpXWutRFXptCKF1DViVMlJqBFgwFgOCm0orlyEUtJleSlTpVVco4guZrcrNwe-8-RwyDbG3Q2DSqQzcGySHjac6ygk_Su0WqvQvBYy17b9spuWQg533lQR51kPO-ctl3cm8XN05tvix6Oemw02isRz1I4-y_OD-Pso7p</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3063471683</pqid></control><display><type>article</type><title>Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation</title><source>Elsevier</source><creator>Gutiérrez, Jose Julio ; Urigüen, Jose Antonio ; Leturiondo, Mikel ; Sandoval, Camilo Leonardo ; Redondo, Koldo ; Russell, James Knox ; Daya, Mohamud Ramzan ; Ruiz de Gauna, Sofía</creator><creatorcontrib>Gutiérrez, Jose Julio ; Urigüen, Jose Antonio ; Leturiondo, Mikel ; Sandoval, Camilo Leonardo ; Redondo, Koldo ; Russell, James Knox ; Daya, Mohamud Ramzan ; Ruiz de Gauna, Sofía</creatorcontrib><description>Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends. Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation. Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (–0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (–0.7 vs. –2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg). Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.</description><identifier>ISSN: 0300-9572</identifier><identifier>ISSN: 1873-1570</identifier><identifier>EISSN: 1873-1570</identifier><identifier>DOI: 10.1016/j.resuscitation.2024.110259</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Capnography ; Compression depth ; CPR ; ETCO2 ; Prognosis ; ROSC ; Ventilation rate</subject><ispartof>Resuscitation, 2024-07, Vol.200, p.110259, Article 110259</ispartof><rights>2024 The Author(s)</rights><rights>Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Gutiérrez, Jose Julio</creatorcontrib><creatorcontrib>Urigüen, Jose Antonio</creatorcontrib><creatorcontrib>Leturiondo, Mikel</creatorcontrib><creatorcontrib>Sandoval, Camilo Leonardo</creatorcontrib><creatorcontrib>Redondo, Koldo</creatorcontrib><creatorcontrib>Russell, James Knox</creatorcontrib><creatorcontrib>Daya, Mohamud Ramzan</creatorcontrib><creatorcontrib>Ruiz de Gauna, Sofía</creatorcontrib><title>Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation</title><title>Resuscitation</title><description>Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends. Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation. Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (–0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (–0.7 vs. –2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg). Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.</description><subject>Capnography</subject><subject>Compression depth</subject><subject>CPR</subject><subject>ETCO2</subject><subject>Prognosis</subject><subject>ROSC</subject><subject>Ventilation rate</subject><issn>0300-9572</issn><issn>1873-1570</issn><issn>1873-1570</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqNkDtPxDAQhC0EEsfBf7BEQ5OwjuM8RIVOx0M66Qqgthx7Az4lcbATJP49CaG5jmqbmW9nhpBrBjEDlt0eYo9hDNoOarCuixNI0pgxSER5QlasyHnERA6nZAUcICpFnpyTixAOAMBFma_Ix8ugOqO8seEXQWulbTPzMFCPjVVVg9R2A_re4_KGuppuXzf7hJrR2-6dtqobVUP1jHH92LSuU_6bHmW7JGe1agJe_d01eXuYIE_Rbv_4vLnfRToBKCNTQpXWutRFXptCKF1DViVMlJqBFgwFgOCm0orlyEUtJleSlTpVVco4guZrcrNwe-8-RwyDbG3Q2DSqQzcGySHjac6ygk_Su0WqvQvBYy17b9spuWQg533lQR51kPO-ctl3cm8XN05tvix6Oemw02isRz1I4-y_OD-Pso7p</recordid><startdate>202407</startdate><enddate>202407</enddate><creator>Gutiérrez, Jose Julio</creator><creator>Urigüen, Jose Antonio</creator><creator>Leturiondo, Mikel</creator><creator>Sandoval, Camilo Leonardo</creator><creator>Redondo, Koldo</creator><creator>Russell, James Knox</creator><creator>Daya, Mohamud Ramzan</creator><creator>Ruiz de Gauna, Sofía</creator><general>Elsevier B.V</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202407</creationdate><title>Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation</title><author>Gutiérrez, Jose Julio ; Urigüen, Jose Antonio ; Leturiondo, Mikel ; Sandoval, Camilo Leonardo ; Redondo, Koldo ; Russell, James Knox ; Daya, Mohamud Ramzan ; Ruiz de Gauna, Sofía</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Capnography</topic><topic>Compression depth</topic><topic>CPR</topic><topic>ETCO2</topic><topic>Prognosis</topic><topic>ROSC</topic><topic>Ventilation rate</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gutiérrez, Jose Julio</creatorcontrib><creatorcontrib>Urigüen, Jose Antonio</creatorcontrib><creatorcontrib>Leturiondo, Mikel</creatorcontrib><creatorcontrib>Sandoval, Camilo Leonardo</creatorcontrib><creatorcontrib>Redondo, Koldo</creatorcontrib><creatorcontrib>Russell, James Knox</creatorcontrib><creatorcontrib>Daya, Mohamud Ramzan</creatorcontrib><creatorcontrib>Ruiz de Gauna, Sofía</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Resuscitation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gutiérrez, Jose Julio</au><au>Urigüen, Jose Antonio</au><au>Leturiondo, Mikel</au><au>Sandoval, Camilo Leonardo</au><au>Redondo, Koldo</au><au>Russell, James Knox</au><au>Daya, Mohamud Ramzan</au><au>Ruiz de Gauna, Sofía</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation</atitle><jtitle>Resuscitation</jtitle><date>2024-07</date><risdate>2024</risdate><volume>200</volume><spage>110259</spage><pages>110259-</pages><artnum>110259</artnum><issn>0300-9572</issn><issn>1873-1570</issn><eissn>1873-1570</eissn><abstract>Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends. Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation. Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (–0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (–0.7 vs. –2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg). Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.resuscitation.2024.110259</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0300-9572
ispartof Resuscitation, 2024-07, Vol.200, p.110259, Article 110259
issn 0300-9572
1873-1570
1873-1570
language eng
recordid cdi_proquest_miscellaneous_3063471683
source Elsevier
subjects Capnography
Compression depth
CPR
ETCO2
Prognosis
ROSC
Ventilation rate
title Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T18%3A20%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Standardisation%20facilitates%20reliable%20interpretation%20of%20ETCO2%20during%20manual%20cardiopulmonary%20resuscitation&rft.jtitle=Resuscitation&rft.au=Guti%C3%A9rrez,%20Jose%20Julio&rft.date=2024-07&rft.volume=200&rft.spage=110259&rft.pages=110259-&rft.artnum=110259&rft.issn=0300-9572&rft.eissn=1873-1570&rft_id=info:doi/10.1016/j.resuscitation.2024.110259&rft_dat=%3Cproquest_cross%3E3063471683%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3063471683&rft_id=info:pmid/&rfr_iscdi=true