Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation
Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and tre...
Saved in:
Published in: | Resuscitation 2024-07, Vol.200, p.110259, Article 110259 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3 |
container_end_page | |
container_issue | |
container_start_page | 110259 |
container_title | Resuscitation |
container_volume | 200 |
creator | Gutiérrez, Jose Julio Urigüen, Jose Antonio Leturiondo, Mikel Sandoval, Camilo Leonardo Redondo, Koldo Russell, James Knox Daya, Mohamud Ramzan Ruiz de Gauna, Sofía |
description | Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends.
Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation.
Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (–0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (–0.7 vs. –2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg).
Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation. |
doi_str_mv | 10.1016/j.resuscitation.2024.110259 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3063471683</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0300957224001527</els_id><sourcerecordid>3063471683</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3</originalsourceid><addsrcrecordid>eNqNkDtPxDAQhC0EEsfBf7BEQ5OwjuM8RIVOx0M66Qqgthx7Az4lcbATJP49CaG5jmqbmW9nhpBrBjEDlt0eYo9hDNoOarCuixNI0pgxSER5QlasyHnERA6nZAUcICpFnpyTixAOAMBFma_Ix8ugOqO8seEXQWulbTPzMFCPjVVVg9R2A_re4_KGuppuXzf7hJrR2-6dtqobVUP1jHH92LSuU_6bHmW7JGe1agJe_d01eXuYIE_Rbv_4vLnfRToBKCNTQpXWutRFXptCKF1DViVMlJqBFgwFgOCm0orlyEUtJleSlTpVVco4guZrcrNwe-8-RwyDbG3Q2DSqQzcGySHjac6ygk_Su0WqvQvBYy17b9spuWQg533lQR51kPO-ctl3cm8XN05tvix6Oemw02isRz1I4-y_OD-Pso7p</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3063471683</pqid></control><display><type>article</type><title>Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation</title><source>Elsevier</source><creator>Gutiérrez, Jose Julio ; Urigüen, Jose Antonio ; Leturiondo, Mikel ; Sandoval, Camilo Leonardo ; Redondo, Koldo ; Russell, James Knox ; Daya, Mohamud Ramzan ; Ruiz de Gauna, Sofía</creator><creatorcontrib>Gutiérrez, Jose Julio ; Urigüen, Jose Antonio ; Leturiondo, Mikel ; Sandoval, Camilo Leonardo ; Redondo, Koldo ; Russell, James Knox ; Daya, Mohamud Ramzan ; Ruiz de Gauna, Sofía</creatorcontrib><description>Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends.
Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation.
Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (–0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (–0.7 vs. –2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg).
Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.</description><identifier>ISSN: 0300-9572</identifier><identifier>ISSN: 1873-1570</identifier><identifier>EISSN: 1873-1570</identifier><identifier>DOI: 10.1016/j.resuscitation.2024.110259</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Capnography ; Compression depth ; CPR ; ETCO2 ; Prognosis ; ROSC ; Ventilation rate</subject><ispartof>Resuscitation, 2024-07, Vol.200, p.110259, Article 110259</ispartof><rights>2024 The Author(s)</rights><rights>Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Gutiérrez, Jose Julio</creatorcontrib><creatorcontrib>Urigüen, Jose Antonio</creatorcontrib><creatorcontrib>Leturiondo, Mikel</creatorcontrib><creatorcontrib>Sandoval, Camilo Leonardo</creatorcontrib><creatorcontrib>Redondo, Koldo</creatorcontrib><creatorcontrib>Russell, James Knox</creatorcontrib><creatorcontrib>Daya, Mohamud Ramzan</creatorcontrib><creatorcontrib>Ruiz de Gauna, Sofía</creatorcontrib><title>Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation</title><title>Resuscitation</title><description>Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends.
Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation.
Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (–0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (–0.7 vs. –2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg).
Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.</description><subject>Capnography</subject><subject>Compression depth</subject><subject>CPR</subject><subject>ETCO2</subject><subject>Prognosis</subject><subject>ROSC</subject><subject>Ventilation rate</subject><issn>0300-9572</issn><issn>1873-1570</issn><issn>1873-1570</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqNkDtPxDAQhC0EEsfBf7BEQ5OwjuM8RIVOx0M66Qqgthx7Az4lcbATJP49CaG5jmqbmW9nhpBrBjEDlt0eYo9hDNoOarCuixNI0pgxSER5QlasyHnERA6nZAUcICpFnpyTixAOAMBFma_Ix8ugOqO8seEXQWulbTPzMFCPjVVVg9R2A_re4_KGuppuXzf7hJrR2-6dtqobVUP1jHH92LSuU_6bHmW7JGe1agJe_d01eXuYIE_Rbv_4vLnfRToBKCNTQpXWutRFXptCKF1DViVMlJqBFgwFgOCm0orlyEUtJleSlTpVVco4guZrcrNwe-8-RwyDbG3Q2DSqQzcGySHjac6ygk_Su0WqvQvBYy17b9spuWQg533lQR51kPO-ctl3cm8XN05tvix6Oemw02isRz1I4-y_OD-Pso7p</recordid><startdate>202407</startdate><enddate>202407</enddate><creator>Gutiérrez, Jose Julio</creator><creator>Urigüen, Jose Antonio</creator><creator>Leturiondo, Mikel</creator><creator>Sandoval, Camilo Leonardo</creator><creator>Redondo, Koldo</creator><creator>Russell, James Knox</creator><creator>Daya, Mohamud Ramzan</creator><creator>Ruiz de Gauna, Sofía</creator><general>Elsevier B.V</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202407</creationdate><title>Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation</title><author>Gutiérrez, Jose Julio ; Urigüen, Jose Antonio ; Leturiondo, Mikel ; Sandoval, Camilo Leonardo ; Redondo, Koldo ; Russell, James Knox ; Daya, Mohamud Ramzan ; Ruiz de Gauna, Sofía</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Capnography</topic><topic>Compression depth</topic><topic>CPR</topic><topic>ETCO2</topic><topic>Prognosis</topic><topic>ROSC</topic><topic>Ventilation rate</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gutiérrez, Jose Julio</creatorcontrib><creatorcontrib>Urigüen, Jose Antonio</creatorcontrib><creatorcontrib>Leturiondo, Mikel</creatorcontrib><creatorcontrib>Sandoval, Camilo Leonardo</creatorcontrib><creatorcontrib>Redondo, Koldo</creatorcontrib><creatorcontrib>Russell, James Knox</creatorcontrib><creatorcontrib>Daya, Mohamud Ramzan</creatorcontrib><creatorcontrib>Ruiz de Gauna, Sofía</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Resuscitation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gutiérrez, Jose Julio</au><au>Urigüen, Jose Antonio</au><au>Leturiondo, Mikel</au><au>Sandoval, Camilo Leonardo</au><au>Redondo, Koldo</au><au>Russell, James Knox</au><au>Daya, Mohamud Ramzan</au><au>Ruiz de Gauna, Sofía</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation</atitle><jtitle>Resuscitation</jtitle><date>2024-07</date><risdate>2024</risdate><volume>200</volume><spage>110259</spage><pages>110259-</pages><artnum>110259</artnum><issn>0300-9572</issn><issn>1873-1570</issn><eissn>1873-1570</eissn><abstract>Interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation (CPR) is affected by variations in ventilation and chest compressions. This study investigates the impact of standardising ETCO2 to constant ventilation rate (VR) and compression depth (CD) on absolute values and trends.
Retrospective study of out-of-hospital cardiac arrest cases with manual CPR, including defibrillator and clinical data. ETCO2, VR and CD values were averaged by minute. ETCO2 was standardised to 10 vpm and 50 mm. We compared standardised (ETs) and measured (ETm) values and trends during resuscitation.
Of 1,036 cases, 287 met the inclusion criteria. VR was mostly lower than recommended, 8.8 vpm, and highly variable within and among patients. CD was mostly within guidelines, 49.8 mm, and less varied. ETs was lower than ETm by 7.3 mmHg. ETs emphasized differences by sex (22.4 females vs. 25.6 mmHg males), initial rhythm (29.1 shockable vs. 22.7 mmHg not), intubation type (25.6 supraglottic vs. 22.4 mmHg endotracheal) and return of spontaneous circulation (ROSC) achieved (34.5 mmHg) vs. not (20.1 mmHg). Trends were different between non-ROSC and ROSC patients before ROSC (–0.3 vs. + 0.2 mmHg/min), and between sustained and rearrest after ROSC (–0.7 vs. –2.1 mmHg/min). Peak ETs was higher for sustained than for rearrest (53.0 vs. 42.5 mmHg).
Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients. Its clinical application for guidance of resuscitation warrants further investigation.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.resuscitation.2024.110259</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0300-9572 |
ispartof | Resuscitation, 2024-07, Vol.200, p.110259, Article 110259 |
issn | 0300-9572 1873-1570 1873-1570 |
language | eng |
recordid | cdi_proquest_miscellaneous_3063471683 |
source | Elsevier |
subjects | Capnography Compression depth CPR ETCO2 Prognosis ROSC Ventilation rate |
title | Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T18%3A20%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Standardisation%20facilitates%20reliable%20interpretation%20of%20ETCO2%20during%20manual%20cardiopulmonary%20resuscitation&rft.jtitle=Resuscitation&rft.au=Guti%C3%A9rrez,%20Jose%20Julio&rft.date=2024-07&rft.volume=200&rft.spage=110259&rft.pages=110259-&rft.artnum=110259&rft.issn=0300-9572&rft.eissn=1873-1570&rft_id=info:doi/10.1016/j.resuscitation.2024.110259&rft_dat=%3Cproquest_cross%3E3063471683%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2009-d90b4fc9c87fd85acf06b2159c10c51e50053dbca17e35f5c20269c4ab413e0c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3063471683&rft_id=info:pmid/&rfr_iscdi=true |