Loading…

Patient and procedural factors associated with true histology rates in patients undergoing colonoscopy with computer-aided detection of polyps

Computer-aided detection (CADe) devices have been shown to increase adenoma detection rates and adenomas per colonoscopy compared to standard colonoscopies. Questions remain about whether CADe colonoscopies are mainly increasing the detection of small, nonneoplastic lesions or if they are detecting...

Full description

Saved in:
Bibliographic Details
Published in:Gastrointestinal endoscopy 2024-12, Vol.100 (6), p.1090-1094.e3
Main Authors: Shaukat, Aasma, Lichtenstein, David R., Chung, Daniel C., Seidl, Caitlyn, Wang, Yeli, Navajas, Emma E., Colucci, Daniel R., Baxi, Shrujal, Brugge, William R.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Computer-aided detection (CADe) devices have been shown to increase adenoma detection rates and adenomas per colonoscopy compared to standard colonoscopies. Questions remain about whether CADe colonoscopies are mainly increasing the detection of small, nonneoplastic lesions or if they are detecting more pathologically meaningful polyps. In this analysis, we compare the true histology rate (defined as polyps with confirmation of clinically relevant histopathology) of CADe-identified polyps with polyps identified during standard colonoscopies. Using data from the SKOUT trial, we compared the true histology rate (THR) between CADe and standard colonoscopies. We also conducted a subgroup analysis by patient, procedural, and endoscopist factors. To account for multiple testing of comparisons, we used the false discovery rate. A total of 1423 participants were included (CADe, n = 714; standard, n = 709). Overall, THR was similar between the CADe and standard colonoscopy arms for adenomas, sessile serrated lesions, and large hyperplastic polyps. Higher THR with CADe colonoscopy was observed in some subgroups for adenomas. Endoscopists with 11 to 20 years of experience and procedures occurring after 12 pm had significantly higher adenoma THRs in the CADe cohort. Patients younger than 65 years, male patients, and procedures with a withdrawal time of ≥8 minutes had borderline significance in the CADe device adenoma THR subgroup. CADe colonoscopies may hold the key to improving endoscopic quality measures, provided that the polyps identified by the CADe device are those of clinical relevance. Although the benefit and significance in the CADe group were demonstrated in this analysis, further research is warranted to ensure that the true histology is maintained when applied in real-world applications.
ISSN:0016-5107
1097-6779
1097-6779
DOI:10.1016/j.gie.2024.06.040