Loading…
Dually-crosslinked ionic conductive hydrogels reinforced through biopolymer gellan gum for flexible sensors to monitor human activities
Human-machine interactions, monitoring of health equipment, and gentle robots all depend considerably on flexible strain sensors. However, making strain sensors have better mechanical behavior and an extensive sensing range remains an urgent difficulty. In this study, poly acrylamide-co-butyl acryla...
Saved in:
Published in: | International journal of biological macromolecules 2024-09, Vol.276 (Pt 1), p.133789, Article 133789 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c245t-83950f3d66b3e333fa88a1bb4e951602eeae8534b386f1f30218584aa90782993 |
container_end_page | |
container_issue | Pt 1 |
container_start_page | 133789 |
container_title | International journal of biological macromolecules |
container_volume | 276 |
creator | Ara, Latafat Sher, Muhammad Khan, Mansoor Rehman, Tanzil Ur Shah, Luqman Ali Yoo, Hyeong-Min |
description | Human-machine interactions, monitoring of health equipment, and gentle robots all depend considerably on flexible strain sensors. However, making strain sensors have better mechanical behavior and an extensive sensing range remains an urgent difficulty. In this study, poly acrylamide-co-butyl acrylate with gellan gum (poly(AAm-co-BA)@GG) hydrophobic association networks and intermolecular hydrogen bonding interactions are used to fabricate dual cross-linked hydrogels for wearable resistive-type strain sensors. This could be an acceptable way to minimize the limitations in hydrogels previously identified. The robust fracture strength (870 kPa) and exceptional stretchability (1297 %) of the hydrogel arise from the collaborative action of intermolecular hydrogen bonding and hydrophobic associations. It also demonstrates exceptional resilience to repeated cycles of uninterrupted stretching and relaxation, retaining its structural integrity. The response and restoration times are 110 and 120 ms respectively. Furthermore, a wide sensing range (0–900 %), notable sensitivity across various strain levels, and an impressive gauge factor (GF) of 31.51 with high durability were observed by the dual cross-linked (DC) hydrogel-based strain sensors. The measured conductivity of the hydrogel was 0.32 S/m which is due to the incorporation of NaCl. Therefore, the hydrogels can be tailored to function as wearable strain sensors that can detect subtle human gestures like speech patterns, distinguish between distinct words, and recognize vibrations of the larynx during drinking, as well as large joint motions like wrist, finger, and elbow. Furthermore, these hydrogels are capable of reliably distinguishing and reproducing various printed text. These findings imply that any electronic device that demands strain-sensing functionality might make use of these developed materials. |
doi_str_mv | 10.1016/j.ijbiomac.2024.133789 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3079172660</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S014181302404594X</els_id><sourcerecordid>3079172660</sourcerecordid><originalsourceid>FETCH-LOGICAL-c245t-83950f3d66b3e333fa88a1bb4e951602eeae8534b386f1f30218584aa90782993</originalsourceid><addsrcrecordid>eNqFkctOwzAQRS0EgvL4hcpLNil2nDj2DsRbQmIDa8txJq2LExc7QfQL-G1cWtiyGmnmzJ3RvQhNKZlRQvnFcmaXtfWdNrOc5MWMMlYJuYcmVFQyI4SwfTQhtKCZoIwcoeMYl6nLSyoO0RETUuZlySfo62bUzq0zE3yMzvZv0GDre2uw8X0zmsF-AF6sm-Dn4CIOYPvWB5OoYRH8OF_g9MXKu3UHASfE6R7Pxw4nCLcOPm3tAEfoow8RDx53SXtIs8XYJVJv9O1gIZ6ig1a7CGe7eoJe725frh-yp-f7x-urp8zkRTlkgsmStKzhvGbAGGu1EJrWdQGypJzkABpEyYqaCd7SlpGcilIUWktSiVxKdoLOt7qr4N9HiIPqbDQ_f4Mfo2KkkrTKOScJ5Vv0x5sArVoF2-mwVpSoTQhqqX5DUJsQ1DaEtDjd3RjrDpq_tV_XE3C5BZKl8GEhqGgs9MlVG8AMqvH2vxvfeySe3w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3079172660</pqid></control><display><type>article</type><title>Dually-crosslinked ionic conductive hydrogels reinforced through biopolymer gellan gum for flexible sensors to monitor human activities</title><source>ScienceDirect Freedom Collection</source><creator>Ara, Latafat ; Sher, Muhammad ; Khan, Mansoor ; Rehman, Tanzil Ur ; Shah, Luqman Ali ; Yoo, Hyeong-Min</creator><creatorcontrib>Ara, Latafat ; Sher, Muhammad ; Khan, Mansoor ; Rehman, Tanzil Ur ; Shah, Luqman Ali ; Yoo, Hyeong-Min</creatorcontrib><description>Human-machine interactions, monitoring of health equipment, and gentle robots all depend considerably on flexible strain sensors. However, making strain sensors have better mechanical behavior and an extensive sensing range remains an urgent difficulty. In this study, poly acrylamide-co-butyl acrylate with gellan gum (poly(AAm-co-BA)@GG) hydrophobic association networks and intermolecular hydrogen bonding interactions are used to fabricate dual cross-linked hydrogels for wearable resistive-type strain sensors. This could be an acceptable way to minimize the limitations in hydrogels previously identified. The robust fracture strength (870 kPa) and exceptional stretchability (1297 %) of the hydrogel arise from the collaborative action of intermolecular hydrogen bonding and hydrophobic associations. It also demonstrates exceptional resilience to repeated cycles of uninterrupted stretching and relaxation, retaining its structural integrity. The response and restoration times are 110 and 120 ms respectively. Furthermore, a wide sensing range (0–900 %), notable sensitivity across various strain levels, and an impressive gauge factor (GF) of 31.51 with high durability were observed by the dual cross-linked (DC) hydrogel-based strain sensors. The measured conductivity of the hydrogel was 0.32 S/m which is due to the incorporation of NaCl. Therefore, the hydrogels can be tailored to function as wearable strain sensors that can detect subtle human gestures like speech patterns, distinguish between distinct words, and recognize vibrations of the larynx during drinking, as well as large joint motions like wrist, finger, and elbow. Furthermore, these hydrogels are capable of reliably distinguishing and reproducing various printed text. These findings imply that any electronic device that demands strain-sensing functionality might make use of these developed materials.</description><identifier>ISSN: 0141-8130</identifier><identifier>ISSN: 1879-0003</identifier><identifier>EISSN: 1879-0003</identifier><identifier>DOI: 10.1016/j.ijbiomac.2024.133789</identifier><identifier>PMID: 38992556</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Dual cross-linking ; Gauge factor ; Human motion monitoring ; Hydrophobic association ; Strain sensor</subject><ispartof>International journal of biological macromolecules, 2024-09, Vol.276 (Pt 1), p.133789, Article 133789</ispartof><rights>2024 Elsevier B.V.</rights><rights>Copyright © 2024. Published by Elsevier B.V.</rights><rights>Copyright © 2024 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c245t-83950f3d66b3e333fa88a1bb4e951602eeae8534b386f1f30218584aa90782993</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38992556$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ara, Latafat</creatorcontrib><creatorcontrib>Sher, Muhammad</creatorcontrib><creatorcontrib>Khan, Mansoor</creatorcontrib><creatorcontrib>Rehman, Tanzil Ur</creatorcontrib><creatorcontrib>Shah, Luqman Ali</creatorcontrib><creatorcontrib>Yoo, Hyeong-Min</creatorcontrib><title>Dually-crosslinked ionic conductive hydrogels reinforced through biopolymer gellan gum for flexible sensors to monitor human activities</title><title>International journal of biological macromolecules</title><addtitle>Int J Biol Macromol</addtitle><description>Human-machine interactions, monitoring of health equipment, and gentle robots all depend considerably on flexible strain sensors. However, making strain sensors have better mechanical behavior and an extensive sensing range remains an urgent difficulty. In this study, poly acrylamide-co-butyl acrylate with gellan gum (poly(AAm-co-BA)@GG) hydrophobic association networks and intermolecular hydrogen bonding interactions are used to fabricate dual cross-linked hydrogels for wearable resistive-type strain sensors. This could be an acceptable way to minimize the limitations in hydrogels previously identified. The robust fracture strength (870 kPa) and exceptional stretchability (1297 %) of the hydrogel arise from the collaborative action of intermolecular hydrogen bonding and hydrophobic associations. It also demonstrates exceptional resilience to repeated cycles of uninterrupted stretching and relaxation, retaining its structural integrity. The response and restoration times are 110 and 120 ms respectively. Furthermore, a wide sensing range (0–900 %), notable sensitivity across various strain levels, and an impressive gauge factor (GF) of 31.51 with high durability were observed by the dual cross-linked (DC) hydrogel-based strain sensors. The measured conductivity of the hydrogel was 0.32 S/m which is due to the incorporation of NaCl. Therefore, the hydrogels can be tailored to function as wearable strain sensors that can detect subtle human gestures like speech patterns, distinguish between distinct words, and recognize vibrations of the larynx during drinking, as well as large joint motions like wrist, finger, and elbow. Furthermore, these hydrogels are capable of reliably distinguishing and reproducing various printed text. These findings imply that any electronic device that demands strain-sensing functionality might make use of these developed materials.</description><subject>Dual cross-linking</subject><subject>Gauge factor</subject><subject>Human motion monitoring</subject><subject>Hydrophobic association</subject><subject>Strain sensor</subject><issn>0141-8130</issn><issn>1879-0003</issn><issn>1879-0003</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkctOwzAQRS0EgvL4hcpLNil2nDj2DsRbQmIDa8txJq2LExc7QfQL-G1cWtiyGmnmzJ3RvQhNKZlRQvnFcmaXtfWdNrOc5MWMMlYJuYcmVFQyI4SwfTQhtKCZoIwcoeMYl6nLSyoO0RETUuZlySfo62bUzq0zE3yMzvZv0GDre2uw8X0zmsF-AF6sm-Dn4CIOYPvWB5OoYRH8OF_g9MXKu3UHASfE6R7Pxw4nCLcOPm3tAEfoow8RDx53SXtIs8XYJVJv9O1gIZ6ig1a7CGe7eoJe725frh-yp-f7x-urp8zkRTlkgsmStKzhvGbAGGu1EJrWdQGypJzkABpEyYqaCd7SlpGcilIUWktSiVxKdoLOt7qr4N9HiIPqbDQ_f4Mfo2KkkrTKOScJ5Vv0x5sArVoF2-mwVpSoTQhqqX5DUJsQ1DaEtDjd3RjrDpq_tV_XE3C5BZKl8GEhqGgs9MlVG8AMqvH2vxvfeySe3w</recordid><startdate>20240901</startdate><enddate>20240901</enddate><creator>Ara, Latafat</creator><creator>Sher, Muhammad</creator><creator>Khan, Mansoor</creator><creator>Rehman, Tanzil Ur</creator><creator>Shah, Luqman Ali</creator><creator>Yoo, Hyeong-Min</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20240901</creationdate><title>Dually-crosslinked ionic conductive hydrogels reinforced through biopolymer gellan gum for flexible sensors to monitor human activities</title><author>Ara, Latafat ; Sher, Muhammad ; Khan, Mansoor ; Rehman, Tanzil Ur ; Shah, Luqman Ali ; Yoo, Hyeong-Min</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c245t-83950f3d66b3e333fa88a1bb4e951602eeae8534b386f1f30218584aa90782993</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Dual cross-linking</topic><topic>Gauge factor</topic><topic>Human motion monitoring</topic><topic>Hydrophobic association</topic><topic>Strain sensor</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ara, Latafat</creatorcontrib><creatorcontrib>Sher, Muhammad</creatorcontrib><creatorcontrib>Khan, Mansoor</creatorcontrib><creatorcontrib>Rehman, Tanzil Ur</creatorcontrib><creatorcontrib>Shah, Luqman Ali</creatorcontrib><creatorcontrib>Yoo, Hyeong-Min</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of biological macromolecules</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ara, Latafat</au><au>Sher, Muhammad</au><au>Khan, Mansoor</au><au>Rehman, Tanzil Ur</au><au>Shah, Luqman Ali</au><au>Yoo, Hyeong-Min</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dually-crosslinked ionic conductive hydrogels reinforced through biopolymer gellan gum for flexible sensors to monitor human activities</atitle><jtitle>International journal of biological macromolecules</jtitle><addtitle>Int J Biol Macromol</addtitle><date>2024-09-01</date><risdate>2024</risdate><volume>276</volume><issue>Pt 1</issue><spage>133789</spage><pages>133789-</pages><artnum>133789</artnum><issn>0141-8130</issn><issn>1879-0003</issn><eissn>1879-0003</eissn><abstract>Human-machine interactions, monitoring of health equipment, and gentle robots all depend considerably on flexible strain sensors. However, making strain sensors have better mechanical behavior and an extensive sensing range remains an urgent difficulty. In this study, poly acrylamide-co-butyl acrylate with gellan gum (poly(AAm-co-BA)@GG) hydrophobic association networks and intermolecular hydrogen bonding interactions are used to fabricate dual cross-linked hydrogels for wearable resistive-type strain sensors. This could be an acceptable way to minimize the limitations in hydrogels previously identified. The robust fracture strength (870 kPa) and exceptional stretchability (1297 %) of the hydrogel arise from the collaborative action of intermolecular hydrogen bonding and hydrophobic associations. It also demonstrates exceptional resilience to repeated cycles of uninterrupted stretching and relaxation, retaining its structural integrity. The response and restoration times are 110 and 120 ms respectively. Furthermore, a wide sensing range (0–900 %), notable sensitivity across various strain levels, and an impressive gauge factor (GF) of 31.51 with high durability were observed by the dual cross-linked (DC) hydrogel-based strain sensors. The measured conductivity of the hydrogel was 0.32 S/m which is due to the incorporation of NaCl. Therefore, the hydrogels can be tailored to function as wearable strain sensors that can detect subtle human gestures like speech patterns, distinguish between distinct words, and recognize vibrations of the larynx during drinking, as well as large joint motions like wrist, finger, and elbow. Furthermore, these hydrogels are capable of reliably distinguishing and reproducing various printed text. These findings imply that any electronic device that demands strain-sensing functionality might make use of these developed materials.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>38992556</pmid><doi>10.1016/j.ijbiomac.2024.133789</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0141-8130 |
ispartof | International journal of biological macromolecules, 2024-09, Vol.276 (Pt 1), p.133789, Article 133789 |
issn | 0141-8130 1879-0003 1879-0003 |
language | eng |
recordid | cdi_proquest_miscellaneous_3079172660 |
source | ScienceDirect Freedom Collection |
subjects | Dual cross-linking Gauge factor Human motion monitoring Hydrophobic association Strain sensor |
title | Dually-crosslinked ionic conductive hydrogels reinforced through biopolymer gellan gum for flexible sensors to monitor human activities |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T03%3A03%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dually-crosslinked%20ionic%20conductive%20hydrogels%20reinforced%20through%20biopolymer%20gellan%20gum%20for%20flexible%20sensors%20to%20monitor%20human%20activities&rft.jtitle=International%20journal%20of%20biological%20macromolecules&rft.au=Ara,%20Latafat&rft.date=2024-09-01&rft.volume=276&rft.issue=Pt%201&rft.spage=133789&rft.pages=133789-&rft.artnum=133789&rft.issn=0141-8130&rft.eissn=1879-0003&rft_id=info:doi/10.1016/j.ijbiomac.2024.133789&rft_dat=%3Cproquest_cross%3E3079172660%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c245t-83950f3d66b3e333fa88a1bb4e951602eeae8534b386f1f30218584aa90782993%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3079172660&rft_id=info:pmid/38992556&rfr_iscdi=true |