Loading…

Feasibility study of shielded diode detector for small field dosimetry

Improved imaging techniques and modern radiotherapy treatment delivery in the treatment field are reduced to the precise size of the tumor, which necessitates the need for small-field dosimetry. Dosimetry in small-field dosimetry is challenging because most of the available code of practice for dosi...

Full description

Saved in:
Bibliographic Details
Published in:Radiation protection dosimetry 2024-07, Vol.200 (11-12), p.1197-1201
Main Authors: Bharathan, Resmi K, Thasni, Irfana, Musthafa, Musthafa, Cheruliyil Ayyappan, Suja, Ajaykumar, Silpa, Jose, Lisha
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c177t-3b097ef4c7c789e27f7afa78cedc7169538c6825f21f1b3c343ea3876cabef5b3
container_end_page 1201
container_issue 11-12
container_start_page 1197
container_title Radiation protection dosimetry
container_volume 200
creator Bharathan, Resmi K
Thasni, Irfana
Musthafa, Musthafa
Cheruliyil Ayyappan, Suja
Ajaykumar, Silpa
Jose, Lisha
description Improved imaging techniques and modern radiotherapy treatment delivery in the treatment field are reduced to the precise size of the tumor, which necessitates the need for small-field dosimetry. Dosimetry in small-field dosimetry is challenging because most of the available code of practice for dosimetry is based on the cavity theory concept. Some small-sized detectors show good spatial resolution and sensitivity. Of the available small detectors, the diamond detector's performance is remarkably good. Most of the centers for radiotherapy lack diamond detectors. In this situation, if a diode detector is available, we can use it for small-field dosimetry by applying the Daisy Chaining method correction methods. In this study, the diode detector's response is not over-responding because of the defective diode. So this diode cannot be used for further measurements, and we have to regularly check the performance of the diode before using it for measurements.
doi_str_mv 10.1093/rpd/ncae051
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3081777992</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3081777992</sourcerecordid><originalsourceid>FETCH-LOGICAL-c177t-3b097ef4c7c789e27f7afa78cedc7169538c6825f21f1b3c343ea3876cabef5b3</originalsourceid><addsrcrecordid>eNo9kM9LwzAcxYMork5P3iVHQeryq01ylOFUGHjRc0mTbzDSLjNpD_3v7dj08HiXD-_BB6FbSh4p0XyV9m61swZIRc9QQaVgJRekPkcFoUKUSjCyQFc5fxPCpK7EJVpwTWhdUVagzQZMDm3owjDhPIxuwtHj_BWgc-CwC9EBdjCAHWLCfk7uTddhfwCwizn0MKTpGl1402W4OfUSfW6eP9av5fb95W39tC0tlXIoeUu0BC-stFJpYNJL441UFpyVtNYVV7ZWrPKMetpyywUHw5WsrWnBVy1fovvj7j7FnxHy0PQhW-g6s4M45oYTNR9JrdmMPhxRm2LOCXyzT6E3aWooaQ7imllccxI303en4bHtwf2zf6b4L3pOaw0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3081777992</pqid></control><display><type>article</type><title>Feasibility study of shielded diode detector for small field dosimetry</title><source>Oxford Journals Online</source><creator>Bharathan, Resmi K ; Thasni, Irfana ; Musthafa, Musthafa ; Cheruliyil Ayyappan, Suja ; Ajaykumar, Silpa ; Jose, Lisha</creator><creatorcontrib>Bharathan, Resmi K ; Thasni, Irfana ; Musthafa, Musthafa ; Cheruliyil Ayyappan, Suja ; Ajaykumar, Silpa ; Jose, Lisha</creatorcontrib><description>Improved imaging techniques and modern radiotherapy treatment delivery in the treatment field are reduced to the precise size of the tumor, which necessitates the need for small-field dosimetry. Dosimetry in small-field dosimetry is challenging because most of the available code of practice for dosimetry is based on the cavity theory concept. Some small-sized detectors show good spatial resolution and sensitivity. Of the available small detectors, the diamond detector's performance is remarkably good. Most of the centers for radiotherapy lack diamond detectors. In this situation, if a diode detector is available, we can use it for small-field dosimetry by applying the Daisy Chaining method correction methods. In this study, the diode detector's response is not over-responding because of the defective diode. So this diode cannot be used for further measurements, and we have to regularly check the performance of the diode before using it for measurements.</description><identifier>ISSN: 0144-8420</identifier><identifier>ISSN: 1742-3406</identifier><identifier>EISSN: 1742-3406</identifier><identifier>DOI: 10.1093/rpd/ncae051</identifier><identifier>PMID: 39016512</identifier><language>eng</language><publisher>England</publisher><subject>Equipment Design ; Feasibility Studies ; Humans ; Radiation Protection - instrumentation ; Radiometry - instrumentation ; Radiometry - methods ; Radiotherapy Dosage ; Semiconductors</subject><ispartof>Radiation protection dosimetry, 2024-07, Vol.200 (11-12), p.1197-1201</ispartof><rights>The Author(s) 2024. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c177t-3b097ef4c7c789e27f7afa78cedc7169538c6825f21f1b3c343ea3876cabef5b3</cites><orcidid>0000-0001-6338-8282</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39016512$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bharathan, Resmi K</creatorcontrib><creatorcontrib>Thasni, Irfana</creatorcontrib><creatorcontrib>Musthafa, Musthafa</creatorcontrib><creatorcontrib>Cheruliyil Ayyappan, Suja</creatorcontrib><creatorcontrib>Ajaykumar, Silpa</creatorcontrib><creatorcontrib>Jose, Lisha</creatorcontrib><title>Feasibility study of shielded diode detector for small field dosimetry</title><title>Radiation protection dosimetry</title><addtitle>Radiat Prot Dosimetry</addtitle><description>Improved imaging techniques and modern radiotherapy treatment delivery in the treatment field are reduced to the precise size of the tumor, which necessitates the need for small-field dosimetry. Dosimetry in small-field dosimetry is challenging because most of the available code of practice for dosimetry is based on the cavity theory concept. Some small-sized detectors show good spatial resolution and sensitivity. Of the available small detectors, the diamond detector's performance is remarkably good. Most of the centers for radiotherapy lack diamond detectors. In this situation, if a diode detector is available, we can use it for small-field dosimetry by applying the Daisy Chaining method correction methods. In this study, the diode detector's response is not over-responding because of the defective diode. So this diode cannot be used for further measurements, and we have to regularly check the performance of the diode before using it for measurements.</description><subject>Equipment Design</subject><subject>Feasibility Studies</subject><subject>Humans</subject><subject>Radiation Protection - instrumentation</subject><subject>Radiometry - instrumentation</subject><subject>Radiometry - methods</subject><subject>Radiotherapy Dosage</subject><subject>Semiconductors</subject><issn>0144-8420</issn><issn>1742-3406</issn><issn>1742-3406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNo9kM9LwzAcxYMork5P3iVHQeryq01ylOFUGHjRc0mTbzDSLjNpD_3v7dj08HiXD-_BB6FbSh4p0XyV9m61swZIRc9QQaVgJRekPkcFoUKUSjCyQFc5fxPCpK7EJVpwTWhdUVagzQZMDm3owjDhPIxuwtHj_BWgc-CwC9EBdjCAHWLCfk7uTddhfwCwizn0MKTpGl1402W4OfUSfW6eP9av5fb95W39tC0tlXIoeUu0BC-stFJpYNJL441UFpyVtNYVV7ZWrPKMetpyywUHw5WsrWnBVy1fovvj7j7FnxHy0PQhW-g6s4M45oYTNR9JrdmMPhxRm2LOCXyzT6E3aWooaQ7imllccxI303en4bHtwf2zf6b4L3pOaw0</recordid><startdate>20240717</startdate><enddate>20240717</enddate><creator>Bharathan, Resmi K</creator><creator>Thasni, Irfana</creator><creator>Musthafa, Musthafa</creator><creator>Cheruliyil Ayyappan, Suja</creator><creator>Ajaykumar, Silpa</creator><creator>Jose, Lisha</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-6338-8282</orcidid></search><sort><creationdate>20240717</creationdate><title>Feasibility study of shielded diode detector for small field dosimetry</title><author>Bharathan, Resmi K ; Thasni, Irfana ; Musthafa, Musthafa ; Cheruliyil Ayyappan, Suja ; Ajaykumar, Silpa ; Jose, Lisha</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c177t-3b097ef4c7c789e27f7afa78cedc7169538c6825f21f1b3c343ea3876cabef5b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Equipment Design</topic><topic>Feasibility Studies</topic><topic>Humans</topic><topic>Radiation Protection - instrumentation</topic><topic>Radiometry - instrumentation</topic><topic>Radiometry - methods</topic><topic>Radiotherapy Dosage</topic><topic>Semiconductors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bharathan, Resmi K</creatorcontrib><creatorcontrib>Thasni, Irfana</creatorcontrib><creatorcontrib>Musthafa, Musthafa</creatorcontrib><creatorcontrib>Cheruliyil Ayyappan, Suja</creatorcontrib><creatorcontrib>Ajaykumar, Silpa</creatorcontrib><creatorcontrib>Jose, Lisha</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiation protection dosimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bharathan, Resmi K</au><au>Thasni, Irfana</au><au>Musthafa, Musthafa</au><au>Cheruliyil Ayyappan, Suja</au><au>Ajaykumar, Silpa</au><au>Jose, Lisha</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Feasibility study of shielded diode detector for small field dosimetry</atitle><jtitle>Radiation protection dosimetry</jtitle><addtitle>Radiat Prot Dosimetry</addtitle><date>2024-07-17</date><risdate>2024</risdate><volume>200</volume><issue>11-12</issue><spage>1197</spage><epage>1201</epage><pages>1197-1201</pages><issn>0144-8420</issn><issn>1742-3406</issn><eissn>1742-3406</eissn><abstract>Improved imaging techniques and modern radiotherapy treatment delivery in the treatment field are reduced to the precise size of the tumor, which necessitates the need for small-field dosimetry. Dosimetry in small-field dosimetry is challenging because most of the available code of practice for dosimetry is based on the cavity theory concept. Some small-sized detectors show good spatial resolution and sensitivity. Of the available small detectors, the diamond detector's performance is remarkably good. Most of the centers for radiotherapy lack diamond detectors. In this situation, if a diode detector is available, we can use it for small-field dosimetry by applying the Daisy Chaining method correction methods. In this study, the diode detector's response is not over-responding because of the defective diode. So this diode cannot be used for further measurements, and we have to regularly check the performance of the diode before using it for measurements.</abstract><cop>England</cop><pmid>39016512</pmid><doi>10.1093/rpd/ncae051</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0001-6338-8282</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0144-8420
ispartof Radiation protection dosimetry, 2024-07, Vol.200 (11-12), p.1197-1201
issn 0144-8420
1742-3406
1742-3406
language eng
recordid cdi_proquest_miscellaneous_3081777992
source Oxford Journals Online
subjects Equipment Design
Feasibility Studies
Humans
Radiation Protection - instrumentation
Radiometry - instrumentation
Radiometry - methods
Radiotherapy Dosage
Semiconductors
title Feasibility study of shielded diode detector for small field dosimetry
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T03%3A12%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Feasibility%20study%20of%20shielded%20diode%20detector%20for%20small%20field%20dosimetry&rft.jtitle=Radiation%20protection%20dosimetry&rft.au=Bharathan,%20Resmi%20K&rft.date=2024-07-17&rft.volume=200&rft.issue=11-12&rft.spage=1197&rft.epage=1201&rft.pages=1197-1201&rft.issn=0144-8420&rft.eissn=1742-3406&rft_id=info:doi/10.1093/rpd/ncae051&rft_dat=%3Cproquest_cross%3E3081777992%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c177t-3b097ef4c7c789e27f7afa78cedc7169538c6825f21f1b3c343ea3876cabef5b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3081777992&rft_id=info:pmid/39016512&rfr_iscdi=true