Loading…
Methodology for shielding design and evaluation for container scanners
There has been an increase in the use of high energy photon beam for container scanners in many countries for multi purposes such as detecting high atomic number materials which might be nuclear materials, drugs, high explosive materials and other contrabands etc. High energy photon beams generally...
Saved in:
Published in: | Radiation protection dosimetry 2024-07, Vol.200 (11-12), p.1167-1172 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c247t-38488477387d0354851fd2348e7bf787a7433623f87c802424f828e55423c0a23 |
container_end_page | 1172 |
container_issue | 11-12 |
container_start_page | 1167 |
container_title | Radiation protection dosimetry |
container_volume | 200 |
creator | Singh, Thokchom D Sha, Rajib L Singh, Ranjankumar K Sahani, Ghanshyam Tandon, Pankaj Sharma, Pankaj Kumar Dash |
description | There has been an increase in the use of high energy photon beam for container scanners in many countries for multi purposes such as detecting high atomic number materials which might be nuclear materials, drugs, high explosive materials and other contrabands etc. High energy photon beams generally 6 and 9 MV can be used for scanning such materials. However, it is important to ensure that radiation level beyond the container scanner installation is within the permissible dose limit specified by the national competent authority for the protection of public and radiation workers. In this paper, challenges in the biological shielding during the installation of high energy X-ray system for scanning vehicles containing suspected materials are discussed. The purpose of the present study is to develop a methodology for shielding design and evaluation for container scanner installations. The basic concept pertaining to shielding evaluation of radiotherapy installations provided in National Council on Radiation Protection and Measurements (NCRP)/International Atomic Energy Agency (IAEA) reports are referred, and appropriately used to calculate optimized shielding thicknesses requirements for container scanner installation. Workload is estimated based on number of containers scanned, machine ON time and dose rate at 1 m. The shielding evaluation includes use of beam stopper in the primary beam, scattering by heterogeneous metallic scrap materials or any other suspected materials contained in the vehicle and their impact on the thickness of shielding walls. A model lay out plan to be used for installation of container scanner is developed. A methodology for shielding evaluation for various protective walls and ceiling of this model is also discussed. The study provides basic requirement for designing a structural room for installing 9MV container scanner from radiological safety view point. |
doi_str_mv | 10.1093/rpd/ncae020 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3081781140</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3081781140</sourcerecordid><originalsourceid>FETCH-LOGICAL-c247t-38488477387d0354851fd2348e7bf787a7433623f87c802424f828e55423c0a23</originalsourceid><addsrcrecordid>eNo90EFPwjAYxvHGaATRk3ezo4mZvO37jpajIaAmGC96Xkrbwcxosd1M-PZOQU_P5Zfn8GfsmsM9hymO486OvdEOBJywIZckciSYnLIhcKJckYABu0jpA0DIaUHnbIBT4BOSOGSLF9dugg1NWO-zKsQsbWrX2NqvM-tSvfaZ9jZzX7rpdFsH_2tM8K2uveu10b7fdMnOKt0kd3XcEXtfzN9mT_ny9fF59rDMjSDZ5qhIKZISlbSABamCV1YgKSdXlVRSS0KcCKyUNAoECaqUUK4oSKABLXDEbg-_uxg-O5faclsn45pGexe6VCIoLhXnBD29O1ATQ0rRVeUu1lsd9yWH8idc2Ycrj-F6fXM87lZbZ__tXyn8BioEaKw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3081781140</pqid></control><display><type>article</type><title>Methodology for shielding design and evaluation for container scanners</title><source>Oxford Journals Online</source><creator>Singh, Thokchom D ; Sha, Rajib L ; Singh, Ranjankumar K ; Sahani, Ghanshyam ; Tandon, Pankaj ; Sharma, Pankaj Kumar Dash</creator><creatorcontrib>Singh, Thokchom D ; Sha, Rajib L ; Singh, Ranjankumar K ; Sahani, Ghanshyam ; Tandon, Pankaj ; Sharma, Pankaj Kumar Dash</creatorcontrib><description>There has been an increase in the use of high energy photon beam for container scanners in many countries for multi purposes such as detecting high atomic number materials which might be nuclear materials, drugs, high explosive materials and other contrabands etc. High energy photon beams generally 6 and 9 MV can be used for scanning such materials. However, it is important to ensure that radiation level beyond the container scanner installation is within the permissible dose limit specified by the national competent authority for the protection of public and radiation workers. In this paper, challenges in the biological shielding during the installation of high energy X-ray system for scanning vehicles containing suspected materials are discussed. The purpose of the present study is to develop a methodology for shielding design and evaluation for container scanner installations. The basic concept pertaining to shielding evaluation of radiotherapy installations provided in National Council on Radiation Protection and Measurements (NCRP)/International Atomic Energy Agency (IAEA) reports are referred, and appropriately used to calculate optimized shielding thicknesses requirements for container scanner installation. Workload is estimated based on number of containers scanned, machine ON time and dose rate at 1 m. The shielding evaluation includes use of beam stopper in the primary beam, scattering by heterogeneous metallic scrap materials or any other suspected materials contained in the vehicle and their impact on the thickness of shielding walls. A model lay out plan to be used for installation of container scanner is developed. A methodology for shielding evaluation for various protective walls and ceiling of this model is also discussed. The study provides basic requirement for designing a structural room for installing 9MV container scanner from radiological safety view point.</description><identifier>ISSN: 0144-8420</identifier><identifier>ISSN: 1742-3406</identifier><identifier>EISSN: 1742-3406</identifier><identifier>DOI: 10.1093/rpd/ncae020</identifier><identifier>PMID: 39016473</identifier><language>eng</language><publisher>England</publisher><subject>Equipment Design ; Humans ; Photons ; Radiation Dosage ; Radiation Protection - instrumentation ; Radiation Protection - standards ; X-Rays</subject><ispartof>Radiation protection dosimetry, 2024-07, Vol.200 (11-12), p.1167-1172</ispartof><rights>The Author(s) 2024. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c247t-38488477387d0354851fd2348e7bf787a7433623f87c802424f828e55423c0a23</cites><orcidid>0000-0002-4022-7272</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39016473$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Singh, Thokchom D</creatorcontrib><creatorcontrib>Sha, Rajib L</creatorcontrib><creatorcontrib>Singh, Ranjankumar K</creatorcontrib><creatorcontrib>Sahani, Ghanshyam</creatorcontrib><creatorcontrib>Tandon, Pankaj</creatorcontrib><creatorcontrib>Sharma, Pankaj Kumar Dash</creatorcontrib><title>Methodology for shielding design and evaluation for container scanners</title><title>Radiation protection dosimetry</title><addtitle>Radiat Prot Dosimetry</addtitle><description>There has been an increase in the use of high energy photon beam for container scanners in many countries for multi purposes such as detecting high atomic number materials which might be nuclear materials, drugs, high explosive materials and other contrabands etc. High energy photon beams generally 6 and 9 MV can be used for scanning such materials. However, it is important to ensure that radiation level beyond the container scanner installation is within the permissible dose limit specified by the national competent authority for the protection of public and radiation workers. In this paper, challenges in the biological shielding during the installation of high energy X-ray system for scanning vehicles containing suspected materials are discussed. The purpose of the present study is to develop a methodology for shielding design and evaluation for container scanner installations. The basic concept pertaining to shielding evaluation of radiotherapy installations provided in National Council on Radiation Protection and Measurements (NCRP)/International Atomic Energy Agency (IAEA) reports are referred, and appropriately used to calculate optimized shielding thicknesses requirements for container scanner installation. Workload is estimated based on number of containers scanned, machine ON time and dose rate at 1 m. The shielding evaluation includes use of beam stopper in the primary beam, scattering by heterogeneous metallic scrap materials or any other suspected materials contained in the vehicle and their impact on the thickness of shielding walls. A model lay out plan to be used for installation of container scanner is developed. A methodology for shielding evaluation for various protective walls and ceiling of this model is also discussed. The study provides basic requirement for designing a structural room for installing 9MV container scanner from radiological safety view point.</description><subject>Equipment Design</subject><subject>Humans</subject><subject>Photons</subject><subject>Radiation Dosage</subject><subject>Radiation Protection - instrumentation</subject><subject>Radiation Protection - standards</subject><subject>X-Rays</subject><issn>0144-8420</issn><issn>1742-3406</issn><issn>1742-3406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNo90EFPwjAYxvHGaATRk3ezo4mZvO37jpajIaAmGC96Xkrbwcxosd1M-PZOQU_P5Zfn8GfsmsM9hymO486OvdEOBJywIZckciSYnLIhcKJckYABu0jpA0DIaUHnbIBT4BOSOGSLF9dugg1NWO-zKsQsbWrX2NqvM-tSvfaZ9jZzX7rpdFsH_2tM8K2uveu10b7fdMnOKt0kd3XcEXtfzN9mT_ny9fF59rDMjSDZ5qhIKZISlbSABamCV1YgKSdXlVRSS0KcCKyUNAoECaqUUK4oSKABLXDEbg-_uxg-O5faclsn45pGexe6VCIoLhXnBD29O1ATQ0rRVeUu1lsd9yWH8idc2Ycrj-F6fXM87lZbZ__tXyn8BioEaKw</recordid><startdate>20240717</startdate><enddate>20240717</enddate><creator>Singh, Thokchom D</creator><creator>Sha, Rajib L</creator><creator>Singh, Ranjankumar K</creator><creator>Sahani, Ghanshyam</creator><creator>Tandon, Pankaj</creator><creator>Sharma, Pankaj Kumar Dash</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-4022-7272</orcidid></search><sort><creationdate>20240717</creationdate><title>Methodology for shielding design and evaluation for container scanners</title><author>Singh, Thokchom D ; Sha, Rajib L ; Singh, Ranjankumar K ; Sahani, Ghanshyam ; Tandon, Pankaj ; Sharma, Pankaj Kumar Dash</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c247t-38488477387d0354851fd2348e7bf787a7433623f87c802424f828e55423c0a23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Equipment Design</topic><topic>Humans</topic><topic>Photons</topic><topic>Radiation Dosage</topic><topic>Radiation Protection - instrumentation</topic><topic>Radiation Protection - standards</topic><topic>X-Rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Singh, Thokchom D</creatorcontrib><creatorcontrib>Sha, Rajib L</creatorcontrib><creatorcontrib>Singh, Ranjankumar K</creatorcontrib><creatorcontrib>Sahani, Ghanshyam</creatorcontrib><creatorcontrib>Tandon, Pankaj</creatorcontrib><creatorcontrib>Sharma, Pankaj Kumar Dash</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiation protection dosimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Singh, Thokchom D</au><au>Sha, Rajib L</au><au>Singh, Ranjankumar K</au><au>Sahani, Ghanshyam</au><au>Tandon, Pankaj</au><au>Sharma, Pankaj Kumar Dash</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Methodology for shielding design and evaluation for container scanners</atitle><jtitle>Radiation protection dosimetry</jtitle><addtitle>Radiat Prot Dosimetry</addtitle><date>2024-07-17</date><risdate>2024</risdate><volume>200</volume><issue>11-12</issue><spage>1167</spage><epage>1172</epage><pages>1167-1172</pages><issn>0144-8420</issn><issn>1742-3406</issn><eissn>1742-3406</eissn><abstract>There has been an increase in the use of high energy photon beam for container scanners in many countries for multi purposes such as detecting high atomic number materials which might be nuclear materials, drugs, high explosive materials and other contrabands etc. High energy photon beams generally 6 and 9 MV can be used for scanning such materials. However, it is important to ensure that radiation level beyond the container scanner installation is within the permissible dose limit specified by the national competent authority for the protection of public and radiation workers. In this paper, challenges in the biological shielding during the installation of high energy X-ray system for scanning vehicles containing suspected materials are discussed. The purpose of the present study is to develop a methodology for shielding design and evaluation for container scanner installations. The basic concept pertaining to shielding evaluation of radiotherapy installations provided in National Council on Radiation Protection and Measurements (NCRP)/International Atomic Energy Agency (IAEA) reports are referred, and appropriately used to calculate optimized shielding thicknesses requirements for container scanner installation. Workload is estimated based on number of containers scanned, machine ON time and dose rate at 1 m. The shielding evaluation includes use of beam stopper in the primary beam, scattering by heterogeneous metallic scrap materials or any other suspected materials contained in the vehicle and their impact on the thickness of shielding walls. A model lay out plan to be used for installation of container scanner is developed. A methodology for shielding evaluation for various protective walls and ceiling of this model is also discussed. The study provides basic requirement for designing a structural room for installing 9MV container scanner from radiological safety view point.</abstract><cop>England</cop><pmid>39016473</pmid><doi>10.1093/rpd/ncae020</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-4022-7272</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0144-8420 |
ispartof | Radiation protection dosimetry, 2024-07, Vol.200 (11-12), p.1167-1172 |
issn | 0144-8420 1742-3406 1742-3406 |
language | eng |
recordid | cdi_proquest_miscellaneous_3081781140 |
source | Oxford Journals Online |
subjects | Equipment Design Humans Photons Radiation Dosage Radiation Protection - instrumentation Radiation Protection - standards X-Rays |
title | Methodology for shielding design and evaluation for container scanners |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T18%3A04%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Methodology%20for%20shielding%20design%20and%20evaluation%20for%20container%20scanners&rft.jtitle=Radiation%20protection%20dosimetry&rft.au=Singh,%20Thokchom%20D&rft.date=2024-07-17&rft.volume=200&rft.issue=11-12&rft.spage=1167&rft.epage=1172&rft.pages=1167-1172&rft.issn=0144-8420&rft.eissn=1742-3406&rft_id=info:doi/10.1093/rpd/ncae020&rft_dat=%3Cproquest_cross%3E3081781140%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c247t-38488477387d0354851fd2348e7bf787a7433623f87c802424f828e55423c0a23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3081781140&rft_id=info:pmid/39016473&rfr_iscdi=true |