Loading…
Dissolving magnesium hydroxide implants enhance mainly cancellous bone formation whereas degrading RS66 implants lead to prominent periosteal bone formation in rabbits
Bone fractures often require internal fixation using plates or screws. Normally, these devices are made of permanent metals like titanium providing necessary strength and biocompatibility. However, they can also cause long-term complications and may require removal. An interesting alternative are bi...
Saved in:
Published in: | Acta biomaterialia 2024-09, Vol.185, p.73-84 |
---|---|
Main Authors: | , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c287t-89f5b624b0b41020a026e91ec9701d62f37c62060b23a64413fba3d57b1463da3 |
container_end_page | 84 |
container_issue | |
container_start_page | 73 |
container_title | Acta biomaterialia |
container_volume | 185 |
creator | Willbold, Elmar Kalla, Katharina Janning, Carla Bartsch, Ivonne Bobe, Katharina Brauneis, Maria Haupt, Maike Reebmann, Mattias Schwarze, Michael Remennik, Sergei Shechtman, Dan Nellesen, Jens Tillmann, Wolfgang Witte, Frank |
description | Bone fractures often require internal fixation using plates or screws. Normally, these devices are made of permanent metals like titanium providing necessary strength and biocompatibility. However, they can also cause long-term complications and may require removal. An interesting alternative are biocompatible degradable devices, which provide sufficient initial strength and then degrade gradually. Among other materials, biodegradable magnesium alloys have been developed for craniofacial and orthopaedic applications. Previously, we tested implants made of magnesium hydroxide and RS66, a strong and ductile ZK60-based alloy, with respect to biocompatibility and degradation behaviour. Here, we compare the effects of dissolving magnesium hydroxide and RS66 cylinders on bone regeneration and bone growth in rabbit condyles using microtomographical and histological analysis. Both magnesium hydroxide and RS66 induced a considerable osteoblastic activity leading to distinct but different spatio-temporal patterns of cancellous and periosteal bone growth. Dissolving RS66 implants induced a prominent periosteal bone formation on the medial surface of the original condyle whereas dissolving magnesium hydroxide implants enhance mainly cancellous bone formation. Especially periosteal bone formation was completed after 6 and 8 weeks, respectively. The observed bone promoting functions are in line with previous reports of magnesium stimulating cancellous and periosteal bone growth and possible underlying signalling mechanisms are discussed.
Biodegradable magnesium based implants are promising candidates for use in orthopedic and traumatic surgery. Although these implants are in the scientific focus for a long time, comparatively little is known about the interactions between degrading magnesium and the biological environment. In this work, we investigated the effects of two degrading cylindrical magnesium implants (MgOH2 and RS66) both on bone regeneration and on bone growth. Both MgOH2 and RS66 induce remarkable osteoblastic activities, however with different spatio-temporal patterns regarding cancellous and periosteal bone growth. We hypothesize that degradation products do not diffuse directionless away, but are transported by the restored blood flow in specific spatial patterns which is also dependent on the used surgical technique.
[Display omitted] |
doi_str_mv | 10.1016/j.actbio.2024.07.035 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3084774020</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1742706124004070</els_id><sourcerecordid>3084774020</sourcerecordid><originalsourceid>FETCH-LOGICAL-c287t-89f5b624b0b41020a026e91ec9701d62f37c62060b23a64413fba3d57b1463da3</originalsourceid><addsrcrecordid>eNp9kduKFDEQhhtR3HX1DURy6U23lUMnPTeCrEdYEDxch6RTPZOhOxmTzOo8ka9pmlkVvPCqquCvv_Lna5qnFDoKVL7Yd2Ys1seOARMdqA54f6-5pIMaWtXL4X7tlWCtAkkvmkc57wH4QNnwsLngG-hrP1w2P1_7nON868OWLGYbMPvjQnYnl-IP75D45TCbUDLBsDNhxCryYT6RcR3mOR4zsTEgmWJaTPExkO87TGgycbhNxq2-nz5L-ddoRuNIieSQ4uIDhkIOmHzMBc38r5cPJBlrfcmPmweTmTM-uatXzde3b75cv29vPr77cP3qph3ZoEo7bKbeSiYsWEGBgQEmcUNx3CigTrKJq1EykGAZN1IIyidruOuVpUJyZ_hV8_zsW5_37Yi56MXnNakJWMNqDoNQSlTrKhVn6ZhizgknfUh-MemkKegVkd7rMyK9ItKgdEVU157dXTjaBd2fpd9MquDlWYA1563HpPPosX638wnHol30_7_wC7xWqAU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3084774020</pqid></control><display><type>article</type><title>Dissolving magnesium hydroxide implants enhance mainly cancellous bone formation whereas degrading RS66 implants lead to prominent periosteal bone formation in rabbits</title><source>Elsevier</source><creator>Willbold, Elmar ; Kalla, Katharina ; Janning, Carla ; Bartsch, Ivonne ; Bobe, Katharina ; Brauneis, Maria ; Haupt, Maike ; Reebmann, Mattias ; Schwarze, Michael ; Remennik, Sergei ; Shechtman, Dan ; Nellesen, Jens ; Tillmann, Wolfgang ; Witte, Frank</creator><creatorcontrib>Willbold, Elmar ; Kalla, Katharina ; Janning, Carla ; Bartsch, Ivonne ; Bobe, Katharina ; Brauneis, Maria ; Haupt, Maike ; Reebmann, Mattias ; Schwarze, Michael ; Remennik, Sergei ; Shechtman, Dan ; Nellesen, Jens ; Tillmann, Wolfgang ; Witte, Frank</creatorcontrib><description>Bone fractures often require internal fixation using plates or screws. Normally, these devices are made of permanent metals like titanium providing necessary strength and biocompatibility. However, they can also cause long-term complications and may require removal. An interesting alternative are biocompatible degradable devices, which provide sufficient initial strength and then degrade gradually. Among other materials, biodegradable magnesium alloys have been developed for craniofacial and orthopaedic applications. Previously, we tested implants made of magnesium hydroxide and RS66, a strong and ductile ZK60-based alloy, with respect to biocompatibility and degradation behaviour. Here, we compare the effects of dissolving magnesium hydroxide and RS66 cylinders on bone regeneration and bone growth in rabbit condyles using microtomographical and histological analysis. Both magnesium hydroxide and RS66 induced a considerable osteoblastic activity leading to distinct but different spatio-temporal patterns of cancellous and periosteal bone growth. Dissolving RS66 implants induced a prominent periosteal bone formation on the medial surface of the original condyle whereas dissolving magnesium hydroxide implants enhance mainly cancellous bone formation. Especially periosteal bone formation was completed after 6 and 8 weeks, respectively. The observed bone promoting functions are in line with previous reports of magnesium stimulating cancellous and periosteal bone growth and possible underlying signalling mechanisms are discussed.
Biodegradable magnesium based implants are promising candidates for use in orthopedic and traumatic surgery. Although these implants are in the scientific focus for a long time, comparatively little is known about the interactions between degrading magnesium and the biological environment. In this work, we investigated the effects of two degrading cylindrical magnesium implants (MgOH2 and RS66) both on bone regeneration and on bone growth. Both MgOH2 and RS66 induce remarkable osteoblastic activities, however with different spatio-temporal patterns regarding cancellous and periosteal bone growth. We hypothesize that degradation products do not diffuse directionless away, but are transported by the restored blood flow in specific spatial patterns which is also dependent on the used surgical technique.
[Display omitted]</description><identifier>ISSN: 1742-7061</identifier><identifier>ISSN: 1878-7568</identifier><identifier>EISSN: 1878-7568</identifier><identifier>DOI: 10.1016/j.actbio.2024.07.035</identifier><identifier>PMID: 39053818</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Biodegradable implants ; Cancellous bone formation ; Magnesium alloy ; Mg(OH)2 ; Periosteal bone formation ; Rapid solidification processing ; RS66</subject><ispartof>Acta biomaterialia, 2024-09, Vol.185, p.73-84</ispartof><rights>2024 The Authors</rights><rights>Copyright © 2024. Published by Elsevier Ltd.</rights><rights>Copyright © 2024 The Authors. Published by Elsevier Ltd.. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c287t-89f5b624b0b41020a026e91ec9701d62f37c62060b23a64413fba3d57b1463da3</cites><orcidid>0000-0002-6408-5424 ; 0000-0001-7270-4187 ; 0009-0000-2369-3581 ; 0000-0001-5059-8029 ; 0000-0001-9154-6217</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39053818$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Willbold, Elmar</creatorcontrib><creatorcontrib>Kalla, Katharina</creatorcontrib><creatorcontrib>Janning, Carla</creatorcontrib><creatorcontrib>Bartsch, Ivonne</creatorcontrib><creatorcontrib>Bobe, Katharina</creatorcontrib><creatorcontrib>Brauneis, Maria</creatorcontrib><creatorcontrib>Haupt, Maike</creatorcontrib><creatorcontrib>Reebmann, Mattias</creatorcontrib><creatorcontrib>Schwarze, Michael</creatorcontrib><creatorcontrib>Remennik, Sergei</creatorcontrib><creatorcontrib>Shechtman, Dan</creatorcontrib><creatorcontrib>Nellesen, Jens</creatorcontrib><creatorcontrib>Tillmann, Wolfgang</creatorcontrib><creatorcontrib>Witte, Frank</creatorcontrib><title>Dissolving magnesium hydroxide implants enhance mainly cancellous bone formation whereas degrading RS66 implants lead to prominent periosteal bone formation in rabbits</title><title>Acta biomaterialia</title><addtitle>Acta Biomater</addtitle><description>Bone fractures often require internal fixation using plates or screws. Normally, these devices are made of permanent metals like titanium providing necessary strength and biocompatibility. However, they can also cause long-term complications and may require removal. An interesting alternative are biocompatible degradable devices, which provide sufficient initial strength and then degrade gradually. Among other materials, biodegradable magnesium alloys have been developed for craniofacial and orthopaedic applications. Previously, we tested implants made of magnesium hydroxide and RS66, a strong and ductile ZK60-based alloy, with respect to biocompatibility and degradation behaviour. Here, we compare the effects of dissolving magnesium hydroxide and RS66 cylinders on bone regeneration and bone growth in rabbit condyles using microtomographical and histological analysis. Both magnesium hydroxide and RS66 induced a considerable osteoblastic activity leading to distinct but different spatio-temporal patterns of cancellous and periosteal bone growth. Dissolving RS66 implants induced a prominent periosteal bone formation on the medial surface of the original condyle whereas dissolving magnesium hydroxide implants enhance mainly cancellous bone formation. Especially periosteal bone formation was completed after 6 and 8 weeks, respectively. The observed bone promoting functions are in line with previous reports of magnesium stimulating cancellous and periosteal bone growth and possible underlying signalling mechanisms are discussed.
Biodegradable magnesium based implants are promising candidates for use in orthopedic and traumatic surgery. Although these implants are in the scientific focus for a long time, comparatively little is known about the interactions between degrading magnesium and the biological environment. In this work, we investigated the effects of two degrading cylindrical magnesium implants (MgOH2 and RS66) both on bone regeneration and on bone growth. Both MgOH2 and RS66 induce remarkable osteoblastic activities, however with different spatio-temporal patterns regarding cancellous and periosteal bone growth. We hypothesize that degradation products do not diffuse directionless away, but are transported by the restored blood flow in specific spatial patterns which is also dependent on the used surgical technique.
[Display omitted]</description><subject>Biodegradable implants</subject><subject>Cancellous bone formation</subject><subject>Magnesium alloy</subject><subject>Mg(OH)2</subject><subject>Periosteal bone formation</subject><subject>Rapid solidification processing</subject><subject>RS66</subject><issn>1742-7061</issn><issn>1878-7568</issn><issn>1878-7568</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kduKFDEQhhtR3HX1DURy6U23lUMnPTeCrEdYEDxch6RTPZOhOxmTzOo8ka9pmlkVvPCqquCvv_Lna5qnFDoKVL7Yd2Ys1seOARMdqA54f6-5pIMaWtXL4X7tlWCtAkkvmkc57wH4QNnwsLngG-hrP1w2P1_7nON868OWLGYbMPvjQnYnl-IP75D45TCbUDLBsDNhxCryYT6RcR3mOR4zsTEgmWJaTPExkO87TGgycbhNxq2-nz5L-ddoRuNIieSQ4uIDhkIOmHzMBc38r5cPJBlrfcmPmweTmTM-uatXzde3b75cv29vPr77cP3qph3ZoEo7bKbeSiYsWEGBgQEmcUNx3CigTrKJq1EykGAZN1IIyidruOuVpUJyZ_hV8_zsW5_37Yi56MXnNakJWMNqDoNQSlTrKhVn6ZhizgknfUh-MemkKegVkd7rMyK9ItKgdEVU157dXTjaBd2fpd9MquDlWYA1563HpPPosX638wnHol30_7_wC7xWqAU</recordid><startdate>20240901</startdate><enddate>20240901</enddate><creator>Willbold, Elmar</creator><creator>Kalla, Katharina</creator><creator>Janning, Carla</creator><creator>Bartsch, Ivonne</creator><creator>Bobe, Katharina</creator><creator>Brauneis, Maria</creator><creator>Haupt, Maike</creator><creator>Reebmann, Mattias</creator><creator>Schwarze, Michael</creator><creator>Remennik, Sergei</creator><creator>Shechtman, Dan</creator><creator>Nellesen, Jens</creator><creator>Tillmann, Wolfgang</creator><creator>Witte, Frank</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-6408-5424</orcidid><orcidid>https://orcid.org/0000-0001-7270-4187</orcidid><orcidid>https://orcid.org/0009-0000-2369-3581</orcidid><orcidid>https://orcid.org/0000-0001-5059-8029</orcidid><orcidid>https://orcid.org/0000-0001-9154-6217</orcidid></search><sort><creationdate>20240901</creationdate><title>Dissolving magnesium hydroxide implants enhance mainly cancellous bone formation whereas degrading RS66 implants lead to prominent periosteal bone formation in rabbits</title><author>Willbold, Elmar ; Kalla, Katharina ; Janning, Carla ; Bartsch, Ivonne ; Bobe, Katharina ; Brauneis, Maria ; Haupt, Maike ; Reebmann, Mattias ; Schwarze, Michael ; Remennik, Sergei ; Shechtman, Dan ; Nellesen, Jens ; Tillmann, Wolfgang ; Witte, Frank</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c287t-89f5b624b0b41020a026e91ec9701d62f37c62060b23a64413fba3d57b1463da3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Biodegradable implants</topic><topic>Cancellous bone formation</topic><topic>Magnesium alloy</topic><topic>Mg(OH)2</topic><topic>Periosteal bone formation</topic><topic>Rapid solidification processing</topic><topic>RS66</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Willbold, Elmar</creatorcontrib><creatorcontrib>Kalla, Katharina</creatorcontrib><creatorcontrib>Janning, Carla</creatorcontrib><creatorcontrib>Bartsch, Ivonne</creatorcontrib><creatorcontrib>Bobe, Katharina</creatorcontrib><creatorcontrib>Brauneis, Maria</creatorcontrib><creatorcontrib>Haupt, Maike</creatorcontrib><creatorcontrib>Reebmann, Mattias</creatorcontrib><creatorcontrib>Schwarze, Michael</creatorcontrib><creatorcontrib>Remennik, Sergei</creatorcontrib><creatorcontrib>Shechtman, Dan</creatorcontrib><creatorcontrib>Nellesen, Jens</creatorcontrib><creatorcontrib>Tillmann, Wolfgang</creatorcontrib><creatorcontrib>Witte, Frank</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Acta biomaterialia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Willbold, Elmar</au><au>Kalla, Katharina</au><au>Janning, Carla</au><au>Bartsch, Ivonne</au><au>Bobe, Katharina</au><au>Brauneis, Maria</au><au>Haupt, Maike</au><au>Reebmann, Mattias</au><au>Schwarze, Michael</au><au>Remennik, Sergei</au><au>Shechtman, Dan</au><au>Nellesen, Jens</au><au>Tillmann, Wolfgang</au><au>Witte, Frank</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dissolving magnesium hydroxide implants enhance mainly cancellous bone formation whereas degrading RS66 implants lead to prominent periosteal bone formation in rabbits</atitle><jtitle>Acta biomaterialia</jtitle><addtitle>Acta Biomater</addtitle><date>2024-09-01</date><risdate>2024</risdate><volume>185</volume><spage>73</spage><epage>84</epage><pages>73-84</pages><issn>1742-7061</issn><issn>1878-7568</issn><eissn>1878-7568</eissn><abstract>Bone fractures often require internal fixation using plates or screws. Normally, these devices are made of permanent metals like titanium providing necessary strength and biocompatibility. However, they can also cause long-term complications and may require removal. An interesting alternative are biocompatible degradable devices, which provide sufficient initial strength and then degrade gradually. Among other materials, biodegradable magnesium alloys have been developed for craniofacial and orthopaedic applications. Previously, we tested implants made of magnesium hydroxide and RS66, a strong and ductile ZK60-based alloy, with respect to biocompatibility and degradation behaviour. Here, we compare the effects of dissolving magnesium hydroxide and RS66 cylinders on bone regeneration and bone growth in rabbit condyles using microtomographical and histological analysis. Both magnesium hydroxide and RS66 induced a considerable osteoblastic activity leading to distinct but different spatio-temporal patterns of cancellous and periosteal bone growth. Dissolving RS66 implants induced a prominent periosteal bone formation on the medial surface of the original condyle whereas dissolving magnesium hydroxide implants enhance mainly cancellous bone formation. Especially periosteal bone formation was completed after 6 and 8 weeks, respectively. The observed bone promoting functions are in line with previous reports of magnesium stimulating cancellous and periosteal bone growth and possible underlying signalling mechanisms are discussed.
Biodegradable magnesium based implants are promising candidates for use in orthopedic and traumatic surgery. Although these implants are in the scientific focus for a long time, comparatively little is known about the interactions between degrading magnesium and the biological environment. In this work, we investigated the effects of two degrading cylindrical magnesium implants (MgOH2 and RS66) both on bone regeneration and on bone growth. Both MgOH2 and RS66 induce remarkable osteoblastic activities, however with different spatio-temporal patterns regarding cancellous and periosteal bone growth. We hypothesize that degradation products do not diffuse directionless away, but are transported by the restored blood flow in specific spatial patterns which is also dependent on the used surgical technique.
[Display omitted]</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>39053818</pmid><doi>10.1016/j.actbio.2024.07.035</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0002-6408-5424</orcidid><orcidid>https://orcid.org/0000-0001-7270-4187</orcidid><orcidid>https://orcid.org/0009-0000-2369-3581</orcidid><orcidid>https://orcid.org/0000-0001-5059-8029</orcidid><orcidid>https://orcid.org/0000-0001-9154-6217</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1742-7061 |
ispartof | Acta biomaterialia, 2024-09, Vol.185, p.73-84 |
issn | 1742-7061 1878-7568 1878-7568 |
language | eng |
recordid | cdi_proquest_miscellaneous_3084774020 |
source | Elsevier |
subjects | Biodegradable implants Cancellous bone formation Magnesium alloy Mg(OH)2 Periosteal bone formation Rapid solidification processing RS66 |
title | Dissolving magnesium hydroxide implants enhance mainly cancellous bone formation whereas degrading RS66 implants lead to prominent periosteal bone formation in rabbits |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T11%3A47%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dissolving%20magnesium%20hydroxide%20implants%20enhance%20mainly%20cancellous%20bone%20formation%20whereas%20degrading%20RS66%20implants%20lead%20to%20prominent%20periosteal%20bone%20formation%20in%20rabbits&rft.jtitle=Acta%20biomaterialia&rft.au=Willbold,%20Elmar&rft.date=2024-09-01&rft.volume=185&rft.spage=73&rft.epage=84&rft.pages=73-84&rft.issn=1742-7061&rft.eissn=1878-7568&rft_id=info:doi/10.1016/j.actbio.2024.07.035&rft_dat=%3Cproquest_cross%3E3084774020%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c287t-89f5b624b0b41020a026e91ec9701d62f37c62060b23a64413fba3d57b1463da3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3084774020&rft_id=info:pmid/39053818&rfr_iscdi=true |